Part Number Hot Search : 
UF2N30Z AN111 AD9761 TMXW306 0603C10 ZL50211 ITR39200 MSK645
Product Description
Full Text Search
 

To Download PDUMH15HVATNET Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  2-2.4kw single-phase ats/switched pdu, lx platform, 200-240v outlets (10 c13), 2 c14 inlets, 3.6 m cords, 1u, taa model number: PDUMH15HVATNET 2?2.4kw ats pdu enables redundant power for non-redundant network devices and provides remote power monitoring. features 2?2.4kw single-phase ats pdu with primary and secondary inputs for power redundancy recommended for data centers, server rooms and network closets, this 1u switched power distribution unit enables redundant a/b power for network devices with single power cords. dual 12-foot (3.7-meter) input cords with c14 plugs connect to separate primary and secondary mains circuits, backup generators, ups systems or utility power grids. plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. the PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source. switches from primary to secondary power source in milliseconds dynamic solid-state automatic transfer switching (ats) allows the iec c13 pdu to switch to the secondary source within 2?5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. an on-board ats processor prevents switching if the secondary source is unavailable or of lower quality than the primary source. switched c13 outlets are individually controllable for remote reboots and load shedding this switched power distribution unit distributes, monitors and manages selectable 200?240v power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. eight switched c13 outlets (two additional c13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the pdu?s total cost of ownership. check essential functions at a glance a front-panel digital load meter displays total pdu output current in amps. leds indicate on/off status of individual outlets and power status of primary and secondary inputs. an input-voltage select switch lets you toggle between high (220, 230 or 240v) or low (200 or 208v) voltage. built-in lx platform interface gives you unrestricted remote access to your equipment 24/7 the java-free html5-based lx platform network interface enables full remote access for pdu status monitoring and email notifications via secure web browser, snmp, telnet or ssh. it supports 10/100 mbps auto-sensing for optimum communication with an ethernet network. optional envirosense2 modules (sold highlights 8 switched and 2 unswitched 200?240v c13 outlets distribute power to connected equipment l built-in java-free html5-based lx platform interface allows you 24/7 remote access l remote power monitoring and control reduces on-site visits and maintenance costs l dual 12 ft. input cords with c14 plugs connect to separate primary/secondary power sources l mounts horizontally in 1u of space in common 19 in. racks for easy installation l applications distribute power to mission- critical devices in small data centers, server rooms and wiring closets whose continuous operation is vital l remotely manage networking equipment in a large industrial or commercial facility l monitor load levels from various servers, switches and other computer network components l package includes PDUMH15HVATNET 2?2.4kw single-phase ats/switched pdu l built-in lx platform interface l configuration cable l (12) plug-lock insert sleeves l (2) c13 to c14 power cords, 12 l 1 / 4
specifications separately) provide a variety of environmental monitoring capabilities. protocols supported include ipv4, ipv6, http, https, smtp, snmpv1, snmpv2, snmpv3, telnet, ssh, ftp, dhcp and ntp. easy to install horizontally in an eia-standard 19 in. rack this ats pdu mounts in 1u of space in 19-inch rack or rack cabinet using the included brackets and hardware. taa-compliant for gsa schedule purchases the PDUMH15HVATNET is compliant with the federal trade agreements act (taa), which makes it eligible for gsa (general services administration) schedule and other federal procurement contracts. 2-year warranty the PDUMH15HVATNET is backed by a 2-year warranty, ensuring reliability and performance. ft. (3.7 m) rack-mounting hardware l owner?s manual l overview upc code 037332197504 pdu type auto-transfer switch; switched output output capacity details 2.4kw (240v), 2.3kw (230v), 2.2kw (220v), 2.08kw (208v), 2.0kw (200v) / 10a total capacity; 10a max per c13 outlet frequency compatibility 50 / 60 hz output receptacles (10) c13 output nominal voltage 200; 208; 220; 230; 240 overload protection n/a customized load management receptacles 8 individually switched c13 output receptacles (2 unswitched) input pdu input voltage 200; 208; 220; 230; 240 maximum input amps 10 pdu plug type (2) iec-320 c14 input cord details set of two c14 inlets and two included cordsets enable connection to separate primary and secondary power sources input cord length (ft.) 12 input cord length (m) 3.66 input phase single-phase user interface, alerts & controls front panel lcd display digital display reports total pdu output current in amps 2 / 4
? 2019 tripp lite. all rights reserved. all product and company names are trademarks or registered trademarks of their respective holders. use of them does not imply any affiliation with or endorsement by them. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. front panel leds 8 leds display power on-off status for each c13 output receptacle, plus 2 additional leds to indicate input power status for primary and secondary inputs switches toggle switch near digital display enables the setting of "hi" for 220, 230 or 240v nominal applications or "lo" for 200 or 208v applications physical minimum required rack depth (inches) 16.7 minimum required rack depth (cm) 42.42 shipping dimensions (hwd / in.) 4.33 x 20.28 x 22.83 shipping dimensions (hwd / cm) 11.00 x 51.51 x 57.99 shipping weight (lbs.) 15.65 shipping weight (kg) 7.10 unit dimensions (hwd / in.) 1.71 x 17.33 x 14.45 unit dimensions (hwd / cm) 4.34 x 44 x 36.7 unit weight (lbs.) 10.41 unit weight (kg) 4.72 material of construction steel form factors supported 1u rackmount pdu form factor horizontal (1u) environmental storage temperature range 5 to 122f (-15 to 50c) relative humidity 5-95% (non-condensing) operating elevation (ft.) 0-10,000 operating elevation (m) 0-3000 communications snmp compatibility pre-installed lx platform interface provides remote monitoring via java-free html5 web interface, telnet, ssh and snmp management systems certifications certifications tested to ul 60950-1 (usa, canada), ce (eu), nom (mexico), gost (russia), en55032:2015 and en62040- 2:2006, fcc class a (emissions), rohs complaint, taa compliant warranty product warranty period (worldwide) 2-year limited warranty 3 / 4
tripp lite uses primary and third-party agencies to test its products for compliance with standards. see a list of tripp lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies 4 / 4


▲Up To Search▲   

 
Price & Availability of PDUMH15HVATNET

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X