Part Number Hot Search : 
CDRH4 A5800855 SZ5234B 2DPSP P1052 MJE13005 3SBBC HBC546
Product Description
Full Text Search
 

To Download LRG5AP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  2011-05-04 1 2011-05-04 advanced power topled datasheet lr g5ap released advanced power topled plus packs outstanding brightness into a mid-power package, making it the perfect light source for thin applications that need bright and homogeneous lighting. advanced power topled plus verfgt ber eine hervorragende helligkeit in einem mid-power geh?use, weshalb sie die perfekte lichtquelle, fr helle und homogene beleuchtung auf kleinstem raum ist. features: besondere merkmale: ? package: white plcc-4 package, colorless clear silicone resin, clear silicone lens ? geh?usetyp: weisses plcc-4 geh?use, farbloser, klarer silikon verguss, klare silikonlinse ? technology: ingaalp thinfilm ? technologie: ingaalp thinfilm ? viewing angle at 50 % i v : 145 ? abstrahlwinkel bei 50 % i v : 145 ? color: red (623 nm) ? farbe: rot (623 nm) ? optical efficiency (typ.): 65 lm/w (red) ? optischer wirkungsgrad (typ.): 65 lm/w (rot) ? esd-withstand voltage: 2 kv acc. to jesd22-a114-d ? esd-festigkeit: 2 kv nach jesd22-a114-d applications anwendungen ? backlighting (lcd, switches, displays, illuminated advertising, general lighting) ? hinterleuchtung (lcd, schalter, displays, werbebeleuchtung, allgemeinbeleuchtung) ? substitution of micro incandescent lamps ? ersatz von kleinst-glhlampen ? decorative and entertainment lighting (incl. fiber optic illumination) ? dekorative beleuchtung ? signal and symbol luminaire for orientation ? signal- und symbolleuchten zur orientierung ? marker lights (e.g. steps, exit ways, etc.) ? markierungsbeleuchtung (z.b. stufen, fluchtwege, u.?.) ? indoor and outdoor commercial and residential architectural lighting ? fassadenbeleuchtung im innen- und au?enbereich
2011-05-04 2 lr g5ap ordering information bestellinformation type luminous intensity 1) page 20 luminous flux 2) page 20 ordering code typ lichtst?rke 1) seite 20 lichtstrom 2) seite 20 bestellnummer i f = 100 ma i f = 100 ma i v (mcd) v typ.(mlm) lr g5ap-bzcz-1-1 2400 ... 4500 12500 q65110a8036 note: the above type numbers represent the order groups which include only a few brightness groups (see page 5 for explanation) . only one group will be shipped on each reel (there will be no mixing of two groups on each reel). e. g. lr g5ap-bzcz-1-1 means that only one group bz, cx, cy, cz will be shippable for any one reel. in order to ensure availability, single brightness groups will not be orderable. in a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any one reel. e. g. lr g5ap-bzcz-1-1 means that only one wavelength group 1 will be shippable. lr g5ap-bzcz-1-1 means that the device will be shipp ed within the specified limits as stated on page 5. in order to ensure availability, single wavelength groups will not be orderable (see pag e 5 for explanation). in a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be ship ped on any one reel. e. g. lr g5ap-bzcz-1-1 means that only one forward voltage group h, l, m will be shippable. in order to ensure availability, s ingle wavelength groups will not be orderable (see page 5 for explanation). anm.: die oben genannten typbezeichnungen umfassen die bestellbaren selektionen. diese bestehen aus wenigen helligkeitsgruppen (siehe seite 5 fr n?here informationen). es wird nur eine einzige helligkeitsgruppe pro gurt geliefert. z. b. lr g5ap-bzcz-1-1 bedeutet, dass auf dem gurt nur eine der helligkeitsgruppen bz, cx, cy, cz enhalten ist. um die liefersicherheit zu gew?hrleisten, k?nnen einzelne helligkeitsgruppe n nicht bestellt werden. gleiches gilt fr die farben, bei denen wellenl?ngengruppen gemessen und gruppiert werden. pro gurt wird nur eine wellenl?ngeng ruppe geliefert. z. b. lr g5ap-bzcz-1-1 bedeutet, dass auf dem gurt nur eine der wellenl?ngengruppen 1 enthalten ist (siehe seite 5 fr n?here i nformationen). lr g5ap-bzcz-1-1 bedeutet, dass das bauteil innerhalb der auf seite 5 spezifizierten grenzen geliefert wird. um die liefersiche rheit zu gew?hrleisten, k?nnen einzelne wellenl?ngengruppen nicht bestellt werden. gleiches gilt fr die leds, bei denen die durchlassspannungsgruppen gemessen und gruppiert werden. pro gurt wird nur eine durchlassspannungsgruppe geliefert. z. b. lr g5ap-bzcz-1-1 bedeutet, dass nach durchlassspannungsgruppen gruppiert wird. auf ei nem gurt ist nur eine der durchlassspannungsgruppen h, l, m enthalten (siehe seite 5 fr n?here informationen). um die liefersicherheit zu g ew?hrleisten, k?nnen einzelne durchlassspannungsgruppen nicht direkt bestellt werden.
lr g5ap 2011-05-04 3 maximum ratings grenzwerte parameter symbol values unit bezeichnung symbol werte einheit operating temperature range betriebstemperatur t op -40 ... + 85 c storage temperature range lagertemperatur t stg -40 ... + 85 c junction temperature sperrschichttemperatur t j + 125 c junction temperature sperrschichttemperatur t j >150 for short term applications c forward current durchlassstrom (t s = 25 c) i f 30 ... 200 ma surge current sto?strom (t <= 10 s, d = 0.005, t s = 25 c) i fm 500 ma reverse voltage sperrspannung (t s = 25 c) v r not designed for reverse operation v
2011-05-04 4 lr g5ap characteristics (t s = 25 c, i f = 100 ma) kennwerte parameter symbol values unit bezeichnung symbol werte einheit wavelength at peak emission wellenl?nge d. emittierten lichtes (typ.) peak 632 nm dominant wavelength * 3) page 20 dominantwellenl?nge * 3) seite 20 (min.) (typ.) (max.) dom dom dom 616 623 628 nm nm nm spectral bandwidth at 50% i rel max spektrale bandbreite b. 50% i rel max (typ.) ? 18 nm viewing angle at 50 % i v abstrahlwinkel bei 50 % i v (typ.) 2 ? 145 forward voltage * 4) page 20 durchlassspannung * 4) seite 20 (min.) (typ.) (max.) v f v f v f 1.80 2.03 2.50 v v v reverse current sperrstrom i r not designed for reverse operation thermal resistance junction / solderpoint ** w?rmewiderstand sperrschicht / l?tpad ** (max.) r thjs 50 k/w thermal resistance junction / solderpoint ** w?rmewiderstand sperrschicht / l?tpad ** (typ.) r thjs 40 k/w note: * individual groups on page 5 ** r th is based on statistic values anm.: * einzelgruppen siehe seilte 5 ** r th basiert auf statistischen werten
lr g5ap 2011-05-04 5 brightness groups helligkeits-gruppierungsschema forward voltage groups 4) page 20 durchlassspannungsgruppe 4) seite 20 wavelength groups (l dom ), chromaticity color coordinate groups 3) page 20 , 5) page 20 wellenl?ngengruppen (l dom ), farbortgruppen 3) seite 20 , 5) seite 20 group brightness 1) page 20 brightness 1) page 20 luminous flux 2) page 20 gruppe lichtst?rke 1) seite 20 lichtst?rke 1) seite 20 lichtstrom 2) seite 20 i v (mcd) i v (mcd) v typ.(mlm) bz 2400 2800 9900 cx 2800 3300 11600 cy 3300 3900 13600 cz 3900 4500 15900 note: the standard shipping format for serial types includes either a lower family group, an upper family group or a grouping o f all individual brightness groups of only a few brightness groups. individual brightness groups cannot be ordered. anm.: die standardlieferform von serientypen beinhaltet entweder eine untere familiengruppe, eine obere familiengruppe oder ein e sammelgruppe, die aus nur wenigen helligkeitsgruppen bestehen. einzelne helligkeitsgruppen sind nicht bestellbar. group red gruppe (min.)[v] (max.)[v] h2.22.5 l1.82.1 m22.3 group red gruppe (min.)[nm] (max.)[nm] 1 616 628 note: no packing unit / tape ever contains more than one color group for each selection. anm.: in einer verpackungseinheit / gurt ist immer nur eine gruppe fr jede farbe enthalten.
2011-05-04 6 lr g5ap group name on label gruppenbezeichnung auf etikett example: bz-1-h beispiel: bz-1-h brightness group helligkeitsgruppe wavelength / chromaticity coordinate group wellenl?nge / farbortgruppe forward voltage group durchlassspannungsgruppe bz 1 h note: no packing unit / tape ever contains more than one group for each selection. anm.: in einer verpackungseinheit / gurt ist immer nur eine gruppe fr jede selektion enthalten.
lr g5ap 2011-05-04 7 relative spectral emission - v( ) = standard eye response curve 2) page 20 , 1) page 20 relative spektrale emission - v( ) = spektrale augenempfindlichkeit 2) seite 20 , 1) seite 20 i rel = f ( ); t s = 25 c; i f = 100 ma radiation characteristics 2) page 20 abstrahlcharakteristik 2) seite 20 i rel = f ( ? ); t s = 25 c 400 450 500 550 600 650 700 [nm] 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 rel : v ohl03691 0? 20? 40? 60? 80? 100? 120? 0.4 0.6 0.8 1.0 100? 90? 80? 70? 60? 50? 0? 10? 20? 30? 40? 0 0.2 0.4 0.6 0.8 1.0 ?
2011-05-04 8 lr g5ap forward current 2) page 20 durchlassstrom 2) seite 20 i f = f (v f ); t s = 25 c relative luminous intensity 2) page 20 , 6) page 20 relative lichtst?rke 2) seite 20 , 6) seite 20 i v /i v (100 ma) = f(i f ); t s = 25 c relative forward voltage 2) page 20 relative vorw?rtsspannung 2) seite 20 v f = v f - v f (25c) = f(t j ); i f = 100 ma relative luminous intensity 2) page 20 relative lichtst?rke 2) seite 20 i v /i v (25)c = f(t j ); i f = 100 ma 1,8 1,9 2,0 2,1 2,2 2,3 2,4 v f [v] 40 60 80 100 120 140 160 180 200 i f [ma] 50 100 150 200 i f [ma] 0,0 0,5 1,0 1,5 2,0 i v i v (100ma) -40 -0.15 ?c t j ohl04417 v f v -20 0 20 40 60 80 120 -0.10 -0.05 0 0.05 0.10 0.15 0.25 ohl04420 -40 ?c j t -20 0 20 40 60 80 120 0 0.2 0.4 0.6 0.8 1.0 1.2 1.6 (25 ?c) i v i v
lr g5ap 2011-05-04 9 dominant wavelength 2) page 20 dominante wellenl?nge 2) seite 20 ? dom = dom - dom (25 c) = f(t j ); i f = 100 ma ohl04423 -6 ? dom nm j t -40 20 0 -20 80 60 40 ?c 120 -4 -2 0 2 4 6 8
2011-05-04 10 lr g5ap max. permissible forward current 7) page 20 maximal zul?ssiger durchlassstrom 7) seite 20 i f = f (t) permissible pulse handling capability zul?ssige impulsbelastbarkeit i f = f(t p ) duty cycle d = parameter, t s = 25 c permissible pulse handling capability zul?ssige impulsbelastbarkeit i f = f(t p ) duty cycle d = parameter, t s = 85 *c 0 0 ?c t i f ma ohl03681 s 20 40 60 80 100 50 100 150 200 300 0 -5 f i a t p s ohl03683 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 10 10 t t t d = p p t i f 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.55 d 0.05 0.1 0.5 0.2 1 0.01 0.02 0.005 = 0 -5 f i a t p s ohl03683 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 10 10 t t t d = p p t i f 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.55 d 0.05 0.1 0.5 0.2 1 0.01 0.02 0.005 =
lr g5ap 2011-05-04 11 package outline 8) page 20 ma?zeichnung 8) seite 20 cathode mark: mark kathodenkennung: markierung corrosion robustness better than en 60068-2-60 (method 4): 40c / 90% rh / 15ppm h 2 s / 336h korrosionsfestigkeit besser als en 60068-2-60 (method 4): 40c / 90% rh / 15ppm h 2 s / 336h approximate weight: 48 mg gewicht: 48 mg
2011-05-04 12 lr g5ap recommended solder pad 8) page 20 reflow soldering empfohlenes l?tpaddesign 8) seite 20 reflow l?ten notes: package not suitable for ultra sonic cleaning. anmerkungen: das geh?use ist fr ultraschallreinigung nicht geeignet. ohpy3665 cu-fl?che 16 mm 2 cu-area 3.8 (0.150) 6.2 (0.244) 1.9 (0.075) 0.3 (0.012) 0.8 (0.031) 1.5 (0.059)
lr g5ap 2011-05-04 13 reflow soldering profile reflow l?tprofil preconditioning: jedec level 4 acc. to jedec s-std-020-d 0 0 s oha04525 50 100 150 200 250 3 00 50 100 150 200 250 3 00 t t ?c s t t p t t p 240 ?c 217 ?c 245 ?c 25 ?c l oha04612 profil-charakteristik profile feature ramp-up rate to preheat* ) 25 ?c t 150 ?c 2 3 k/s time from t smin to t smax 150 ?c t s 200 ?c t s t l t p t l t p 100 120 60 10 20 30 80 100 217 23 245 260 36 time 25 ?c t t p time within 5 ?c of the specified peak temperature t p - 5 k ramp-down rate* t p t 100 ?c all temperatures refer to the center of the package, measured on the top of the component * slope calculation t/ t: t max. 5 s; fulfillment for the whole t-range ramp-up rate to peak* ) t smax t t p liquidus temperature peak temperature time above liquidus temperature symbol symbol einheit unit pb-free (snagcu) assembly minimum maximum recommendation k/s k/s s s s s ?c ?c 480
2011-05-04 14 lr g5ap method of taping 8) page 20 gurtung 8) seite 20 ohty3600 1.5 (0.059) +0.1 (0.004) 5.5 (0.217) 12 (0.472) 4 (0.157) 1.75 (0.069) 2 (0.079) 0.05 (0.002) 3.6 (0.142) 0.05 (0.002) 6.05 (0.238) 0.3 (0.012) 0.05 (0.002) 2.25 (0.089) 1.4 (0.055) 8 (0.315) 1.5 (0.059) cathode/ collector side
lr g5ap 2011-05-04 15 tape and reel gurtverpackung 12 mm tape with 3500/reel, ? 330 mm tape dimensions in mm (inch) tape dimensions in mm (inch) reel dimensions in mm (inch) reel dimensions in mm (inch) w p 0 p 1 p 2 d 0 e f 12 +0.3/-0.1 4 0.1 (0.157 0.004) 8 0.1 (0.315 0.004) 2 0.05 (0.079 0.002) 1.5 0.1 (0.059 + 0.004) 1.75 0.1 (0.069 0.004) 5.5 0.05 (0.217 0.002) a w n min w 1 w 2max 180 (7) 12 (0.472) 60 (2.362) 12.4 + 2 (0.488 + 0.079) 18.4 (0.724) 330 (13) 12 (0.472) 60 (2.362) 12.4 + 2 (0.488 + 0.079) 18.4 (0.724) d 0 2 p p 0 1 p w fe direction of unreeling n w 1 2 w a ohay0324 label gurtvorlauf: leader: trailer: gurtende: 13.0 direction of unreeling 0.25 160 mm 160 mm 400 mm 400 mm
2011-05-04 16 lr g5ap barcode-product-label (bpl) barcode-produkt-etikett (bpl) dry packing process and materials trockenverpackung und materialien note: moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. regarding dry pack you will find further information in the internet and in the short form catalog in chapter ?tape and reel? under the topic ?dry pack?. here you will also find the normative references like jedec. anm.: feuchteempfindliche produkte sind verpackt in einem trockenbeutel zusammen mit einem trockenmittel und einer feuchteindikatorkarte. bezglich trockenverpackung finden sie weitere hinweise im internet und in unserem short form catalog im kapitel ?gurtung und verpackung? unter dem punkt ?trockenverpackung?. hier sind normenbezge, unter anderem ein auszug der jedec-norm, enthalten. oha04563 (g) group: 1234567890 (1t) lot no: (9d) d/c: 1234 (x) prod no: 123456789 (6p) batch no: 1234567890 lx xxxx rohs compliant bin1: xx-xx-x-xxx-x ml 2 temp st 260 c r pack: r18 demy 022 b_r999_1880.1642 r 9999 (q)qty: semiconductors osram opto xx-xx-x-x oha00539 o sram moisture-sensitive label or print barcode label desiccant humidity indicator barcode label osram please check the hic immidiately after bag opening. discard if circles overrun. avoid metal contact. wet do not eat. comparator check dot parts still adequately dry. examine units, if necessary examine units, if necessary 5% 15% 10% bake units bake units if wet, change desiccant if wet, humidity indicator mil-i-8835 if wet, m o is tu r e l e ve l 3 f lo o r tim e 1 6 8 h ou r s m oi s tu r e l e vel 6 f lo o r t im e 6 h o u rs a ) h um i d it y in d ica to r c a r d is > 1 0 % w he n r e a d a t 2 3 ?c 5 ?c , o r re f lo w , v a p o r-p h a s e r e flo w , o r e qu i va le n t p ro c e ss in g ( p e ak pa c k a g e 2 . a ft er th i s b ag is op e n ed , d ev ic e s t ha t w il l be su bje cte d to i n fra red 1 . s he lf life in s e al e d b a g: 2 4 m o nt h s a t < 40 ?c a n d < 9 0% re la ti v e h um id it y ( r h ) . m o is tu r e l e v el 5 a a t f a ct o r y c o n d ition s o f ( if bla n k , s e a l da te i s ide n tic a l w ith d a te c o d e ). a ) m o u n te d w i th in b ) s to re d a t b od y t e m p . 3 . d ev ic e s re qu ire b a k in g , b e fo r e m o un t in g , if : b ag s ea l d a te m oi s tu r e l e v el 1 m o is tu re l e v e l 2 m o is tu re l e v e l 2 a 4 . i f ba k ing i s re q u ir e d , b ) 2 a o r 2b is n o t m e t. d a te a n d tim e o pe n e d : r e fe re n c e i p c / j e d e c j- s t d - 0 3 3 fo r b a k e p r o ce d u r e . f lo o r tim e se e b el o w if b la n k , s e e b a r c o d e l a be l f lo o r tim e > 1 y ea r f lo o r t i m e 1 y e a r f lo o r ti m e 4 w e e k s 1 0 % r h . _ < m ois t ur e l e v e l 4 m o ist u r e l ev e l 5 ?c ). o pt o s e m ic on du c to r s m o is t u r e se n s it iv e t his b ag c on ta i ns c a u t io n f l oo r tim e 7 2 h o u rs f l oo r tim e 4 8 h o u rs f lo o r tim e 2 4 h ou rs 3 0 ? c / 6 0% r h . _ < l e v e l i f b la n k , s e e b a r c o d e l a b e l
lr g5ap 2011-05-04 17 transportation packing and materials kartonverpackung und materialien dimensions of transportation box in mm (inch) width / breite length / l?nge height / h?he 349 5 (13,740 0,196) 349 5 (13,740 0,196) 33 5 (1,299 0,196) safety advice sicherheits hinweise none keine the evaluation of eye safety occurs according to the standard iec 62471:2006 ("photobiological safety of lamps and lamp systems"). within the risk grouping system of this cie standard, the led specified in this data sheet fall into the class exempt group (exposure time 10000s). under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. as a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. as is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. die bewertung der augensicherheit erfolgt nach dem standard iec 62471:2006 ("photobiological safety of lamps and lamp systems"). im risikogruppensystem dieser cie- norm erfllen die in diesem datenblatt angegebenen leds folgende gruppenanforderung - exempt group (expositionsdauer 10000s). unter realen umst?nden (fr expositionsdauer, augenpupille, betrachtungsabstand) geht damit von diesen bauelementen keinerlei augengef?hrdung aus. grunds?tzlich sollte jedoch erw?hnt werden, dass intensive lichtquellen durch ihre blendwirkung ein hohes sekund?res gefahrenpotenzial besitzen. nach einem blick in eine helle lichtquelle (z.b. autoscheinwerfer), kann ein tempor?r eingeschr?nktes sehverm?gen oder auch nachbilder zu irritationen, bel?stigungen, beeintr?chtigungen oder sogar unf?llen fhren. oha02044 p a c k v a r : r 0 7 7 a d d it io n a l t e x t p - 1 + q - 1 m u lt i t o p l e d muster o s r a m o p to s e m i c o n d u c t o r s ( 6 p ) b a t c h n o : ( x ) p r o d n o : 1 0 ( 9 d ) d / c : 1 1 ( 1 t ) l o t n o : 2 1 0 0 2 1 9 9 8 1 2 3 g h 1 2 3 4 0 2 45 ( q ) q t y : 2 0 0 0 0 1 4 4 ( g ) g r o u p : 2 6 0 c r t 2 4 0 c r 3 2 2 0 c r m l b i n 3 : b i n 2 : q - 1 - 2 0 b i n 1 : p - 1 - 2 0 l s y t 6 7 6 2 2 a t e m p s t r 1 8 d e m y p a c k v a r : r 0 7 7 a d d i t i o n a l t e x t p - 1 + q - 1 m u l t i t o p l e d muster o s r a m o p to s em ic o n du c to rs ( 6 p ) b a t c h n o : ( x ) p r o d n o : 1 0 ( 9 d ) d / c : 1 1 ( 1 t ) l o t n o : 210021998 1 2 3 g h 1 2 3 4 0 2 45 ( q ) q t y : 2 0 0 0 0 1 4 4 ( g ) g r o u p : 2 6 0 c r t 2 4 0 c r 3 2 2 0 c r m l b i n 3 : b i n 2 : q - 1 - 2 0 b i n 1 : p - 1 - 2 0 l s y t 6 7 6 2 2 a t e m p s t r 1 8 d e m y osram packing sealing label barcode label m ois tu re lev e l 3 f lo or ti m e 1 68 h o urs m o is ture le ve l 6 f lo or tim e 6 ho urs a) h um idi ty in di ca tor c a r d is > 1 0 % wh en rea d a t 23 ?c 5 ?c , o r re fl ow , v ap or -ph a s e re flow , o r e q uiv ale nt p ro ces si ng (p ea k pa c k age 2. a fter this b ag is o pe ned, de v ice s th at w ill be s ub je c ted to in frar e d 1 . s helf life in s e ale d ba g : 2 4 m o n th s at < 40 ?c an d < 9 0% rela tiv e hu m idi ty ( r h) . m ois tu re le ve l 5a a t f ac tor y c ond itio n s o f (if b lank , se a l d ate is i den tic al w ith d ate c od e ). a) m ou nted w ithi n b) s to red at b o dy tem p . 3. d ev ic e s req ui re bak in g, befo re m o un ting , if : b ag s eal d a te m ois tur e l e v el 1 m o is tu re l ev el 2 m oi stu re lev el 2a 4. i f ba kin g is re qu ire d, b) 2 a or 2b is n o t m e t. d ate an d tim e op ene d: refer en ce ip c /j e d ec j -s t d- 03 3 fo r b ak e p ro ce dure . f lo o r tim e s ee b e low i f blan k , se e ba r c od e la bel f l oor tim e > 1 y e ar flo or t im e 1 y ea r flo or tim e 4 w ee ks 1 0% r h . _ < m ois tu re leve l 4 m ois tur e le ve l 5 ?c ). o p t o s em ic o n d uc t or s m o is tu r e s en s it iv e this ba g c on tain s c au t io n f lo o r ti m e 7 2 h ou rs flo o r tim e 48 h ou rs f lo or ti m e 24 ho urs 3 0 ?c / 6 0% r h . _ < l e v e l i f b l a n k , s e e b a r c o d e l a b e l barcode label
2011-05-04 18 lr g5ap revision history: 2011-05-04 previous version: page subjects (major changes since last revision) date of change all preliminary datasheet created 2010-12-14 all final datasheet released 2011-05-04
lr g5ap 2011-05-04 19 disclaimer disclaimer attention please! the information describes the type of component and shall not be considered as assured characteristics. terms of delivery and rights to change design reserved. due to technical requirements components may contain dangerous substances. for information on the types in question please contact our sales organization. if printed or downloaded, please find the latest version in the internet. packing please use the recycling operators known to you. we can also help you ? get in t ouch with your nearest sales office. by agreement we will take packing material back, if it is sorted. you must bear the costs of transport. for packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. components used in life-support devices or systems must be expressly authorized for such purpose! critical components* may only be used in life-support devices** or systems with the express written approval of osram os. *) a critical component is a component used in a life-support device or system whose failure can reasonably be expected to c ause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) life support devices or systems are intended(a) to be implanted in the human body,or(b) to support and/or maintain and sustain human life.if they fail, it is reasonable to assume that the health and the life of the user may be endangered. bitte beachten! lieferbedingungen und ?nderungen im design vorbehalten. aufgrund technischer anforderungen k?nnen die bauteile gefahrstoffe enthalten. fr weitere informationen zu gewnschten bauteilen, wenden sie sich bitte an unseren vertrieb.falls sie diese datenblatt ausgedruckt oder heruntergeladen haben, finden sie die aktuellste version im internet. verpackung benutzen sie bitte die ihnen bekannten recyclingwege. wenn diese nicht bekannt sein sollten, wenden sie sich bitte an das n?chstgelegene vertriebsbro. wir nehmen das verpackungsmaterial zurck, falls dies vereinbart wurde und das material sortiert ist. sie tragen die transportkosten. fr verpackungsmaterial, das unsortiert an uns zurckgeschickt wird oder das wir nicht annehmen mssen, stellen wir ihnen die anfallenden kosten in rechnung. bauteile, die in lebenserhaltenden apparaten und systemen eingesetzt werden, mssen fr diese zwecke ausdrcklich zugelassen sein! kritische bauteile* drfen in lebenserhaltenden apparaten und systemen nur dann eingesetzt werden, wenn ein schriftliches einverst?ndnis von osram os vorliegt. *) ein kritisches bauteil ist ein bauteil, das in lebenserhaltenden apparaten oder systemen eingesetzt wird und dessen defekt voraussichtlich zu einer fehlfunktion dieses lebenserhaltenden apparates oder systems fhren wird oder die scherheit oder effektivit?t dieses apparates oder systems beeintr?chtigt. **) lebenserhaltende apparate oder systeme sind fr (a) die implantierung in den menschlichen k?rper oder (b) fr die lebenserhaltung bestimmt. falls sie versagen, kann davon ausgegangen werden, dass die gesundheit und das leben des patienten in gefahr ist.
2011-05-04 20 lr g5ap glossary glossar 1) brightness : brightness values are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/- 8 % and an expanded uncertainty of +/- 11 % (acc. to gum with a coverage factor of k = 3). 1) helligkeit : helligkeitswerte werden w?hrend eines strompulses einer typischen dauer von 25 ms, mit einer internen reproduzierbarkeit von +/- 8 % und einer erweiterten messunsicherheit von +/- 11 % gemessen (gem?? gum mit erweiterungsfaktor k = 3). 2) typical values : due to the special conditions of the manufacturing processes of led, the typical data or calculated correlations of technical parameters can only reflect statistical figures. these do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. if requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 2) typische werte : wegen der besonderen prozessbedingungen bei der herstellung von led k?nnen typische oder abgeleitete technische parameter nur aufgrund statistischer werte wiedergegeben werden. diese stimmen nicht notwendigerweise mit den werten jedes einzelnen produktes berein, dessen werte sich von typischen und abgeleiteten werten oder typischen kennlinien unterscheiden k?nnen. falls erforderlich, z.b. aufgrund technischer verbesserungen, werden diese typischen werte ohne weitere ankndigung ge?ndert. 3) dominant wavelength : the dominant wavelength is measured at a current pulse of typical 25 ms, with an internal reproducibility of +/- 0,5 nm and an expanded uncertainty of +/- 1 nm (acc. to gum with a coverage factor of k=3). 3) dominantwellenl?nge : die dominante wellenl?nge wird w?hrend eines strompulses einer typischen dauer von 25 ms, mit einer internen reproduzierbarkeit von +/- 0,5 nm und einer erweiterten messunsicherheit von +/- 1 nm gemessen (gem?? gum mit erweiterungsfaktor k = 3). 4) forward voltage : the forward voltage is measured during a current pulse of typical 8 ms, with an internal reproducibility of +/- 0,05 v and an expanded uncertainty of +/- 0,1 v (acc. to gum with a coverage factor of k=3). 4) durchlassspannung : vorw?rtsspannungen werden w?hrend eines strompulses einer typischen dauer von 8 ms, mit einer internen reproduzierbarkeit von +/- 0,05 v und einer erweiterten messunsicherheit von +/- 0,1 v gemessen (gem?? gum mit erweiterungsfaktor k=3). 5) chromaticity coordinate groups : chromaticity coordinates are measured during a current pulse of typical 25 ms, with an internal reproducibility of +/- 0,005 and an expanded uncertainty of +/- 0,01 (acc. to gum with a coverage factor of k = 3). 5) farbortgruppen : farbkoordinaten werden w?hrend eines strompulses einer typischen dauer von 25 ms, mit einer internen reproduzierbarkeit von +/? 0,005 und einer erweiterten messunsicherheit von +/? 0,01 gemessen (gem?? gum mit erweiterungsfaktor k = 3). 6) relative luminous intensity : in the range where the line of the graph is broken, you must expect higher brightness differences between single leds within one packing unit. 6) relative lichtst?rke : im gestrichelten bereich der kennlinien muss mit erh?hten helligkeitsunterschieden zwischen leuchtdioden innerhalb einer verpackungseinheit gerechnet werden. 7) thermal resistance : rthja results from mounting on pc board fr 4 (pad size ? 16 mm2 per pad) 7) w?rmewiderstand : rthja ergibt sich bei montage auf pc-board fr 4 (padgr??e ? 16 mm2 je pad) 8) tolerance of measure : dimensions are specified as follows: mm (inch). 8) ma?toleranz : ma?e werden wie folgt angegeben: mm (inch).
lr g5ap 2011-05-04 21 published by osram opto semiconductors gmbh leibnizstra?e 4, d-93055 regensburg www.osram-os.com ? all rights reserved.


▲Up To Search▲   

 
Price & Availability of LRG5AP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .