  ? phoenix contact - 10/2008 100500_en_01 interface PSI-DATA/fax-modem/rs232 data sheet 1description the din rail-mountable psi- data/fax-modem/rs232 is specifically designed to meet industrial requirements for remote maintenance. it provides global access to machines and systems via permanent an d dial-up line connections according to the v.34 standard. a wide range of security functions, such as adjustable selective call acceptance, connection establishment with password protection, and call-back function, protect the system against unauthorized access. one particularly useful feature for remote system monitoring is the configurable warning or alarm inpu t. if this input is activated, the modem calls a user-defined number and sends a stored text message by fax or sms. to ensure interference-free operation even in harsh emc conditions, the device has high-quality 3-way isolation an d integrated surge protection. the modem also features an integrated automatic "sleep" function to increase batter y life and an extremely wide supply voltage range of 10 v to 60 v, making it suitable for universal use. modem startup is very easy using plug and play and user-friendly configuration software. the modem is approved for use in public telephone networks in europe, the us a, and canada. additional approvals can be provided on request. attention: the PSI-DATA/fax-modem/rs232 is designed ex clusively for selv operation according to iec 60950/en 60950/vde 0805. the modem must only be connected to devices, whic h meet the requirements of en 60950 ("safety of information technology devices"). if you have any technical problems, wh ich you cannot resolve with the aid of this documentation, please contact us during the usual office hours at: phone: +49 - 52 35 - 31 98 90 fax: +49 - 52 35 - 33 09 99 e-mail: interface-service@phoenixcontact.com make sure you always use the latest documentation. it can be downloaded at www.phoenixcontact.com . this data sheet is valid for all pr oducts listed on the following page: industrial analog modem
PSI-DATA/fax-modem/rs232 100500_en_01 phoenix contact 2 2ordering data v.34 modem: description type order no. pcs./pkt. industrial analog modem , din rail-mountable, dial-up and permanent line operation in europe, usa, canada, v.24 (rs-232) interface, 3-way isolation, alarm i/o, 24 v ac/dc supply voltage scope of supply: modem, cd with conf iguration software and user manual, and rj12 cable PSI-DATA/fax-modem/rs232 2708203 1 general accessories description type order no. pcs./pkt. din rail bus connector (3 required) me 17,5 tbus 1,5/ 5-st-3,81 gn 2709561 1 system power supply unit primary-switched input voltage range nominal output voltage nominal output current 45 hz ... 65 hz 85 v ac ... 264 v ac 24 v dc 1% 1.5 a mini-sys-ps-100-240ac/24dc/1.5 2866983 1 surge protection for analog telecommunications interfaces, din rail- mountable mt-2fm-rj12 2838937 1 psi-modem-splitter, switching module to access two control systems via one modem psi-modem-splitter 2708766 1 cables/conductors description type order no. pcs./pkt. connecting cable , 9-pos. d-sub to usb, with 9-pos. d-sub to 25-pos. d-sub adapter cm-kbl-rs232/usb 2881078 1 short v.24 (rs-232) flat-ribbon connecting cable between modem and psi-modem-splitter psi-ca-modem-splitter 2311425 1 v.24 (rs-232) cable , 0.5 m, 9-pos. d-sub female connector to 9-pos. d-sub female connector psm-ka9sub9/bb/0,5meter 2708520 1 v.24 (rs-232) cable, 2 m, 9-pos. d-sub female connector to 9-pos. d-sub female connector psm-ka9sub9/bb/2meter 2799474 1 adapters description type order no. pcs./pkt. psm-ad-d9-nullmodem, rs-232 (v.24) null modem connector, 9-pos. d-sub female connector to 9-pos. d-sub male connector psm-ad-d9-nullmodem 2708753 1 adapter cable for connecting the ib il rs232 and ib il rs232-pro inline communication terminals psm-kad-il rs232/9sub/b/0,8m 2319200 1 mpi adapter for coupling to the programming interface of a simatic ? s7-300/400 controller psi-mpi/rs232-pc 2313148 1 documentation description type order no. pcs./pkt. user manual for the industrial analog modem PSI-DATA/fax-modem/rs232 um e 2699354 1
PSI-DATA/fax-modem/rs232 100500_en_01 phoenix contact 3 3 technical data power supply supply voltage 1 10 v dc ... 60 v dc, 16 v ac ... 40 v ac via combicon plug-in screw terminal block frequency dc or 50 hz ... 60 hz supply voltage 2, alternative or redundant 24 v dc 5% via backplane bus contact and system power supply current consumption nominal operation sleep mode (can be configured via software) < 100 ma at 24 v < 40 ma at 24 v led indicator vcc (green led): ? steady light: operation ? flashing: sleep mode v.24 (rs-232) interface connection 9-pos. d-sub pin strip device type data communication equipment (dce) data format serial asynchronous uart/nrz encoding 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length serial transmission speed automatic data rate detection (default) or fixed setting at 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (adjustable via software) data flow control software handshake: xon/xoff hardware handshake: rts/cts no handshake or 3964r led indicator/data indicator td (gre en led), data to modem (dynamic) rd (yellow led), data from modem (dynamic) led indicator/control signal indicator dtr (yellow led), data terminal ready dcd (yellow led), data carrier detect pstn port (a/b line) connection rj12, 6-pos., or combic on plug-in screw terminal block shield dc coupled to din rail operating modes dial-up mod em, 2-wire half/full duplex fax modem, 2-wire half duplex permanent line, 2-wire full duplex dialing procedure multiple frequency/pulse dialin g, configuration via software transmission speed dce/dce fax automatic adjustment according to v.8 300 baud to 33.6 kbaud 2400 baud to 14.4 kbaud compatibility itu v.42bis, v.42, v.34 extended, itu v.32bis, v.32, v.21, v.22bis, v.22, v.23, bell 212a and 103, itu v.17, group 3 t.4, t.30, and eia tr-29 fax compatibility eia tr-29 class 2, ccitt v.17, group 3, v.29, v27ter command set compatibility at standard command set and ex tended, v.250 basic command set error correction v.42 (lap-m or mnp 2 to 4) data compression v.42bis (throughput 4:1), mnp 5 (throughput 2:1)
PSI-DATA/fax-modem/rs232 100500_en_01 phoenix contact 4 led indicator/data indicator green led (oh), off the hook yellow led (aa), automatic answer, flas hes during selective call acceptance yellow led (fax), fax mode active yellow led (ec), error correction in v.42 mode, flashes when data compression is active acoustic signaling integrated piezo startup diagnostics power on se lftest, visualization via leds (controller, sram, eeprom, dsp) adaptive line test dial tone test, pulse dial ring test vi a additional function in configuration software telecommunications approvals tbr21, tbr15, tia/eia/is-968 for europe, usa, and canada hardware settings 4-pos. dip switch for dial-up and permanent line operation (under removable cover) pstn port (a/b line) (continued) switching input and output switching input u n 24 v dc/5 ma, 9 v dc ... 48 v dc input voltage range, floating, activates one or more of the following: ? message to the local v.24 (rs-232) interface ? sms (only in dial-up operation) ? fax (only in dial-up operation) ? output control at the remote station (via sms) switching output 60 v dc/1 a or 42 v ac/1 a miniatur e switching relay, n/o contact, activated by: ? input control at the remote station ? sms (only in dial-up operation) ? local at command ? at command at the remote station signaling alr (red led) ? flashing: sms/fax error message to be sent ? steady light: alarm has been triggered err (red led) ? steady light: alarm cannot be triggered reset (acknowledgment) by: ? sms (remote) ? at command (local + remote) ? button (local) text and telephone number memory text memory sms fax 160 characters 480 characters, 30 kb telephone number memory 20 telephone numbers with a maximum of 36 digits
PSI-DATA/fax-modem/rs232 100500_en_01 phoenix contact 5 general data ce conformance emc directive 89/336/eec approvals u ex: u ambient operating temperature range 0c ? 55c housing material dimensions (h x w x d) me 35 with 5-pos. bus contact and ground contact abs-v0, green 99 x 35 x 114.5 mm weight of device 165 g functional earth ground housing contact with din rail vibration resistance according to din en 60068-2-6 5g, 1.5 h each in x, y, and z direction shock test operation storage according to din en 60068-2-27 15g, 11 ms, half-sine shock pulse 30g, 11 ms, half-sine shock pulse free fall according to iec 60068-2-32 from a height of 1 m (without packaging) degree of protection ip20 3-way electrical isolation power supply // pstn // v.24 (rs-232) test voltage 1.5 kv ac, 50 hz, 1 min. between all ground levels according to en 50178 and en 61131-2 electromagnetic compatibility noise immunity according to en 61000-6-2 1 electrostatic discharge (esd) en 61000-4-2 criterion b 2 8 kv air discharge 6 kv contact discharge electromagnetic hf field amplitude modulation pulse modulation en 61000-4-3 criterion a 3 10 v/m 10 v/m fast transients (burst) signal power supply en 61000-4-4 criterion a 3 1 kv/5 khz criterion a 3 2 kv/5 khz surge current load (surge) signal power supply en 61000-4-5 criterion b 2 1 kv 2 kv conducted interference en 61000-4-6 criterion a 3 10 v noise emission en 55022 limiting curve b 1 en 61000 corresponds to iec 1000 2 criterion b: temporary adverse effects on the operating characteristics which the device corrects automatically. 3 criterion a: normal operating beha vior within the specified limits.
PSI-DATA/fax-modem/rs232 100500_en_01 phoenix contact 6 4features ? for universal use ? password-protected access/ call-back function/selective call acceptance ? configurable input and output ? alarm sent directly by sms or fax via the integrated switching inpu t (or via at commands) ? sends, receives, and evaluates sms messages ? wide supply voltage range of 10 v dc ... 60 v dc or 14 v ac ... 40 v ac ? power-saving sleep mode ? high-quality three-way isolation (vcc // v.24 (rs-232) // ptsn) ? integrated surge protection ? easy startup using plug an d play and user-friendly configuration software ? 3964r-compatible 5 application the PSI-DATA/fax-modem/rs 232 modem can be used universally and internationally for all popular modem applications in the following operating modes: ? dial-up modem ?fax modem ? permanent line modem ? for remote monitoring of systems and machines ? for remote control ? for system diagnostics ? for production data acquisition ? for automatic alarm generation this device is approved for op eration in the following public telephone networks: ?belgium ?denmark ?germany ?france ? finland ? greece ?great britain ?italy ?ireland ? canada ? luxembourg ? the netherlands ?norway ?austria ? portugal ?sweden ?switzerland ?spain ?usa approvals for other countries are available on request.
PSI-DATA/fax-modem/rs232 100500_en_01 7 phoenix contact gmbh & co. kg ? 32823 blombe rg ? germany ? phone: +49 - 52 35 - 30 0 phoenix contact ? p.o.box 4100 ? harrisburg ? pa 17111-0100 ? usa ? phone: +717-944-1300 www.phoenixcontact.com figure 1 dial-up operation figure 2 permanent line operation figure 3 alarm generation telephone network (pstn) 20 km telephone network (pstn)


▲Up To Search▲   

 
Price & Availability of PSI-DATA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X