  carling technologies, inc. 60 johnson avenue, plainville, ct 06062 email: sales @ carlingtech.com application support: team2 @ carlingtech.com phone: 860.793.9281 fax: 860.793.9231 www.carlingtech.com applications: ? household appliances ? transportation ? marine ? power strips ? medical equipment ? audio visual equipment ? power supplies ? exercise equipment ? rohs complaint ctb-series thermal circuit protectors the ctb-series is a compact, single pole, rocker actuated family of thermal circuit breakers designed to protect equipment. utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. electrical ratings range from 3 to 16 amps at 125, 250vac or 50vdc. this breaker resets with the push of a fnger and features a snap in mounting style, utilizing a 16mm dia. round double d mounting hole. product highlights: ? ratings from 3-16a, 125, 250vac, 50vdc ? .250 tabs ? 60c max operating temperature ? 1000 aic interrupting capacity ? 100m ohms insulation resistance ? ul, cul, vde, ce ctb
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com 2 | ctb-series - ordering scheme, time delay, dimensional specifcations *manufacturer reserves the right to change product specification without prior notice. recommended panel thickness: .032 - .062 [.81-1.57 1 series 2 bezel color 3 rocker color 4 rating 5 panel thickness ctb b b 05 b 1 series ctb 2 bezel color 1 b black 3 rocker color 1 b black 4 rating 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 09 9 amps 10 10 amps 12 12 amps 13 13 amps 14 14 amps 15 15 amps 16 16 amps 5 panel thickness blank fts standard thickness of .032 C .062 b fts .070 C .110 panel thickness dimensional specifications: in. [mm] notes: 1. additional colors available. consult factory. notes: all dimensions are in inches [millimeters].tolerance .005 [.127] unless otherwise specifed. breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. trip times specifed at 25 ambient with no preloading. correction factor 1 0 c x 0.85 10 c x 0.90 15 c x 0.925 18 c x 0.952 25 c x 1.00 32 c x 1.05 40 c x 1.15 50 c x 1.39 60 c x 1.49 overload trip time 100% no trip 135% trip in 1 hr 200% 2.2 ~ 15 sec. 300% 0.9 ~ 3.4 sec. 400% 0.57 ~ 1.6 sec. 500% 0.38 ~ 0.94 sec. 600% 0.27 ~ 0.76 sec. notes: 1. to adjust the breaker rating for ambient temperature, multiply the breaker rating by the factor. ex: 5a rating x .850 = 4.25a. select 4a rating. time delay percentage of rated current trip time in seconds
email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com email: sales @ carlingtech.com application support: team2@carlingtech.com phone: (860) 793C9281 fax: (860) 793C9231 www.carlingtech.com | 3 sales representatives, distributors & company profle authorized sales representatives and distributors about carling founded in 1920, carling technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. with four iso registered manufacturing facilities and technical sales ofces worldwide, carling technologies sales, service and engineering teams do much more than manufacture electrical components, they engineer powerful solutionsf to learn more about carling please visit www.carlingtech.com/company-profle . to view all of carlings environmental, quality, health & safety certifcations please visit www.carlingtech.com/environmental-certifcations click on a region of the map below to fnd your local representatives and distributors or visit www.carlingtech.com/fndarep . europe middle east south america asia-pacific oceania africa mexico usa canada
worldwide headquarters carling technologies, inc. 60 johnson avenue, plainville, ct 06062 phone:f 860.793.9281 fax:f 860.793.9231 email: sales @ carlingtech.com northernfregionfsalesfofce:f nrsm @ carlingtech.com southeastfregionfsalesfofce: sersm @ carlingtech.com midwestfregionfsalesfofce: mrsm @ carlingtech.com westfregionfsalesfofce: wrsm @ carlingtech.com latinfamericafsalesfofce: larsm @ carlingtech.com asia-pacific headquarters carling technologies, asia-pacifc ltd., suite 1607, 16/f tower 2, the gateway, harbour city, 25 canton road, tsimshatsui, kowloon, hong kong phone:f int + 852-2737-2277 fax: int + 852-2736-9332 email: sales @ carlingtech.com.hk shenzhen,fchina:f shenzhen @ carlingtech.com shanghai,fchina:f shanghai @ carlingtech.com pune,findia: india @ carlingtech.com kaohsiung,ftaiwan:f taiwan @ carlingtech.com yokohama,fjapan: japan @ carlingtech.com europe | middle east | africa headquarters carling technologies ltd 4 airport business park, exeter airport, clyst honiton, exeter, devon, ex5 2ul, uk phone:f int + 44 1392.364422 fax:f int + 44 1392.364477 email:f ltd.sales @ carlingtech.com germany:f gmbh @ carlingtech.com france:f sas @ carlingtech.com www.carlingtech.com rev_11_2016


▲Up To Search▲   

 
Price & Availability of CTB-B-B-03

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X