  Datasheet File OCR Text:
  3.86w x 8.03l x 1.57h 320 watts output power single output universal 90-264vac input 5vdc to 48vdc outputs 5656vdc input to output isolation active power factor correction model number output voltage output amps (max) ripple & noise max. effciency single output pmmk320s-5d 5 vdc 60 100mv pk-pk 71% PMMK320S-12D 12 vdc 26.7 120mv pk-pk 77% pmmk320s-15d 15 vdc 21.4 150mv pk-pk 79% pmmk320s-24d 24 vdc 13.4 150mv pk-pk 79% pmmk320s-36d 36 vdc 8.9 150mv pk-pk 81% pmmk320s-48d 48 vdc 6.7 150mv pk-pk 81% all specifcations are typical at nominal input, full load, and 25c unless other - wise noted 320 watt medical grade din rail mount power supply with pfc pmmk320d series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
input specifications input voltage range 90-264 vac; nom: 100-240vac frequency range 47-63 hz power factor correction 0.95, min. nom i/p, fl inrush current, typ: 30a @ 115vac cold start, fl * 60a @ 230vac cold start, fl * input current 5.4 amps max., 90v i/p 1.8 amps max., 264v i/p leakage current <0.3ma, 240vin, 50hz output specifications voltage and current see selection chart line regulation (ll-hl) 1%, max. (1.5% 5 vout) load regulation 10%-fl 1~1.5%, max. preset accuracy (note 3) 1%, typ (2% 5 vout) ripple/noise (notes 1, & 4) see selection chart over voltage protection 130% max. auto recovery * over current protection 160% max. auto recovery * short circuit protection auto recover after fault condition is removed * turn on delay time <4s rise time <25ms, typ (nom i/p, fl) hold up time 20ms, typ (nom i/p, fl) over-shoot/under shoot <10% of nominal output remote sense compensates for up to 0.5v drop remote shutdown open collector, logic 1 = on 0 = off. no termination necessary to maintain constant on operation physical specifications size 8.03(l) x 3.86(w) x 1.57(h) construction enclosed weight 1.77 lb, (802g) general specifications isolation (note 2) i/p-o/p: 5656vdc i/p-ground: 2121vdc o/p-ground: 707vdc insulation resistance 20m? effciency (fl. nom i/p) see selection chart safety ul/cul: ansi/aami es60601-1 3rd ed. csa c22.2 no. 60601-1 3rd ed. ul-eu: en60601-1 3rd ed. cb: iec60601-1 3rd ed. ce: en60601-1-2 environmental specifications oper. temperature -20 to +70c (see derate curve) storage temperature -25 to +85c * relative humidity 10% to +90%, * storage: 5-95% ems harmonics class d, 61000-3-2 fluctuations 61000-3-3 esd 61000-4-2 rs 61000-4-3 eft 61000-4-4 surge 61000-4-5 cs 61000-4-6 ms 61000-4-8 dips 61000-4-11 emi en55022 class b mtbf mil std 217f, 25c 65,000 hrs, min. vibration 4g peak, 50-500hz, 3 axes drop test 70 cm notes 1. all measurements should be made directly at the terminals of the power supply 2. isolation for up to 1 minute duration. 3. preset accuracy measured at nominal load, 120vac input. 4. o/p noise measured directly at the pins/terminals at nominal load, 0.1uf ceramic bypass and 47uf electrolytic, pk-pk @ 20mhz bandwidth. * these are stress ratings. exposure of the devices to any of these conditions may adversely affect long term reliability. proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. 320 watt medical grade din rail mount power supply with pfc pmmk320d series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
98 3.86 178 7.01 203.9 8.03 fg acl 110 4.33 40 1.57 38 1.50 23.9 .94 21 .83 acn 151.1 5.95 50.8 2.00 23.6 .93 12.7 .50 13 .51 82.50 3.25 49 1.93 +vo(5v) com com com +vo +vo -s +s s/d gnd units:mm (in) weight: pmmk320-a193 proprietary and confidential the information contained in this drawing is the sole property of . any reproduction in part or as a whole without the written permission of is prohibited. comments: sheet 1 of 1 q.a. mfg appr. eng appr. checked drawn date name dimensions are in inches tolerances: fractional angular: mach bend two place decimal three place decimal next assy used on application do not scale drawing finish material rev. a dwg. no. size scale:1:1 mechanical dimensions m3 i : 3p 8.25 o : 6p 8.25 320 watt medical grade din rail mount power supply with pfc pmmk320d series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
output derating curve a a a s s s t t t r r r o o o d d d y y y n n n e e e p p p a a a c c c i i i f f f i i i c c c c c c o o o r r r p p p e e e l l l e e e c c c t t t r r r i i i c c c a a a l l l s s s p p p e e e c c c i i i f f f i i i c c c a a a t t t i i i o o o n n n 7. derating curve 0% 20% 40% 60% 80% 100% 120% -20 -10 10 20 30 40 50 60 70 load(%) ambient ( ) input voltage (vac) 60hz ta=25 1. 5v 2. 12 15 24 36 48v 4214 320 watt medical grade din rail mount power supply with pfc pmmk320d series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458


▲Up To Search▲   

 
Price & Availability of PMMK320S-12D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X