|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
pm4s product types par ts name ?the pm4s multi-range timer allows time units and output contacts to be selected via front switches. multi-range analog timer pm4s timers type /////// contact arrangement time range operating voltage part no. pm4s multi-range timer a type pow er on-delay t. d. : timed-out 2c inst.: timed-out 1c instantaneous 1c (selected by front switch) 1s/10s/1min/10min (4 time ranges selectable) 100 to 120v ac pm4s-a2c10m-ac120v 200 to 240v ac pm4s-a2c10m-ac240v 12v dc pm4s-a2c10m-dc12v 24v dc pm4s-a2c10m-dc24v pm4s multi-range timer b type 3s/30s/3min/30min (4 time ranges selectable) 100 to 120v ac pm4s-a2c30m-ac120v 200 to 240v ac pm4s-a2c30m-ac240v 12v dc pm4s-a2c30m-dc12v 24v dc pm4s-a2c30m-dc24v pm4s multi-range ttimer c type 6s/60s/6min/60min (4 time ranges selectable) 100 to 120v ac pm4s-a2c60m-ac120v 200 to 240v ac pm4s-a2c60m-ac240v 12v dc pm4s-a2c60m-dc12v 24v dc pm4s-a2c60m-dc24v pm4s multi-range timer d type 1min/10min/1h/10h (4 time ranges selectable) 100 to 120v ac pm4s-a2c10h-ac120v 200 to 240v ac pm4s-a2c10h-ac240v 12v dc pm4s-a2c10h-dc12v 24v dc pm4s-a2c10h-dc24v pm4s multi-range timer e type 3min/30min/3h/30h (4 time ranges selectable) 100 to 120v ac PM4S-A2C30H-AC120V 200 to 240v ac pm4s-a2c30h-ac240v 12v dc pm4s-a2c30h-dc12v 24v dc pm4s-a2c30h-dc24v features 1. economic pricing that promptly re?cts market demands remarkable economic pricing is implemented in pursuit of cost performance. 2. output contacts switchable between timed out 2c and timed out 1c/instantaneous 1c the timed out 1c/instantaneous 1c output contact enables the ef?ient addition of self-maintenance circuits. 3. 4 different time ranges selectable on a single unit five types of timers cover the full range of time settings from 1 second to 30 hours. 4. equipped with zero-setting instantaneous output set the dial all the way to ? for instantaneous operation, so circuit testing can be easily accomplished. 5. compliant with ul, c-ul and ce. rohs directive compatibility information http://www.nais-e.com/ time unit selector time range selector output contact selector all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd.
pm4s speci?ations applicable standard safety standard en61812-1 pollution degree 2/overvoltage category iii emc (emi)en61000-6-4 radiation interference electric ?ld strength noise terminal voltage (ems)en61000-6-2 static discharge immunity rf electromagnetic ?ld immunity eft/b immunity surge immunity conductivity noise immunity pow er frequency magnetic ?ld immunity voltage dip/instantaneous stop/voltage ?ctuation immunity en55011 group1 classa en55011 group1 classa en61000-4-2 4 kv contact 8 kv air en61000-4-3 10 v/m am modulation (80 mhz to 1 ghz) 10 v/m pulse modulation (895 mhz to 905 mhz) en61000-4-4 2 kv (power supply line) en61000-4-5 1 kv (power line) en61000-4-6 10 v/m am modulation (0.15 mhz to 80 mhz) en61000-4-8 30 a/m (50 hz) en61000-4-11 10 ms, 30% (rated voltage) 100 ms, 60% (rated voltage) 1,000 ms, 60% (rated voltage) 5,000 ms, 95% (rated voltage) notes) 1. unless otherwise speci?d, the measurement conditions at the maximum scale time standard are speci?d to be the rated operating voltage (within 5% ripple factor for dc), 20? 68? ambient temperature, and 1s power off time. 2. for the 1s range, the tolerance for each speci?ation becomes ?0ms. type item pm4s multi-range timer rating rated operating voltage 100 to 120v ac 200 to 240v ac 12v dc 24v dc rated frequency 50/60 hz rated power consumption approx. 3.0va/3.6va (at 100v ac) approx. 4.5va/5.25va (at 120v ac) approx. 5.6va/6.8va (at 200v ac) approx. 7.5va/9.8va (at 240v ac) approx. 1.3w approx. 1.7w output rating 5a 250v ac (resistive load) operating mode power on-delay time range a type 1s/10s/1min/10min (4 time ranges selectable) b type 3s/30s/3min/30min (4 time ranges selectable) c type 6s/60s/6min/60min (4 time ranges selectable) d type 1min/10min/1h/10h (4 time ranges selectable) e type 3min/30min/3h/30h (4 time ranges selectable) time accuracy note) operating time ?ctuation ?% (power off time change at the range of 0.1s to 1h) setting error ?% (full-scale value) voltage error ?% (at the operating voltage changes between 85 to 110%) t emperature error ?% (at 20? ambient temp. at the range of ?0 to +50? +14 to +122? ) contact contact arrangement t. d. : timed-out 2 form c inst.: timed-out 1 form c, instantaneous 1 form c (selected by front switch) contact resistance (initial value) max. 100m ? (at 1a 6v dc) contact material silver alloy life mechanical (contact) min. 10 7 electrical (contact) min. 10 5 (at raed control capacity) electrical function allowable operating voltage range 85 to 110% of rated operating voltage insulation resistance (initial value) min. 100m ? between live and dead metal parts (at 500v dc) between input and output between contacts of different poles between contacts of same pole breakdown voltage (initial value) 2,000vrms for 1 min between live and dead metal parts 2,000vrms for 1 min between input and output 2,000vrms for 1 min between contacts of different poles 1,000vrms for 1 min between contacts of same pole min. power off time 100 ms max. temperature rise 55? 131? mechanical function vibration resistance functional 10 to 55hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes) destructive 10 to 55hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes) shock resistance functional min. 98m/s 2 (4 times on 3 axes) destructive min. 980m/s 2 (5 times on 3 axes) operating condition ambient temperature ?0 to +50? +14 to +122? ambient humidity 30 to 85%rh (non-condensing) atmospheric pressure 860 to 1,060hpa ripple factor (dc type) 20% others weight approximately 110 g 3.880 oz all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. pm4s dimension (unit: mm inch ) tolerance: 0.5 .020 operation mode 5.5 63.7 14.2 .217 2.508 .559 14.5 .571 48 1.890 44.5 1.752 ?surface mount dimensions din rail terminal block at8-df8k (sold separately) 102.2 4.024 device installation rail at8-dla1 (sold separately) ?panel mount dimensions (with mounting frame) ?panel cut out dimensions standard cut out dimensions are shown below. use mounting frame (at8-da4) and rubber gasket (atc18002). ?adjacent mounting 84.7 3.335 50 1.969 mounting frame at8-da4 (sold separately) rear terminal socket at78041 (sold separately) panel (thickness 1 to 3.5 mm .039 to .138 inch ) +0.6 0 45 +.024 0 1.772 min. 80 3.150 min. 80 3.150 +0.6 0 45 +.024 0 1.772 a = (48 n?.5) a +0.6 0 45 +.024 0 1.772 +0.6 0 a = (1.890 n?098) +.024 0 ?terminal layouts and wiring diagrams operating voltage com com no no nc nc mode 1 2 3 4 5 6 7 8 t. d. : timed-out 2 form c inst.: timed-out 1 form c, instantaneous 1 form c * selected by front switch 4 3 1 1 4 3 t. d. i n s t. notes: 1. operating voltage signs in parentheses ( ) indicate the polarity of the dc type. 2. is a time delay contact. is an instantaneous contact. 1. t.d. mode 2. inst. mode on t on off off pow er supply time out (n.o. contact) 1 3 or 6 8 op.led note: keep 0.1s or more for power off time. on on t on off off off pow er supply time out (n.o. contact) 6 8 time out (n.o. contact) 1 3 op.led all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. pm4s precautions during usage acquisition of ce marking 1. avoid locations subject to ?mmable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks. 2. since the main-unit is made of polycarbonate resin, avoid contact with or use in environments containing methyl alcohol, benzene, thinners, and other organic solvents; and ammonia, caustic sodas, and other alkaline substances. 3. power supply superimposed surge protector although a surge protector will withstand standard-waveform voltage with the values in the next table, anything above this will destroy the internal circuit. you should therefore use a surge absorber. ?surge waveform [ (1.2 50) s uni-polar full wave voltage] 4. in order to maintain the characteristics, do not remove the timer case. 5. when installing the panel, use the at a4811 mounting frame (sold separately). 6. if you change the operating voltage, be sure not to allow leak current into the timer. 7. avoid leaving the unit powered continuously. leaving the unit powered up with output set to on continuously for a long period of time (about 1 month or more) will wear out the electronic components. if you will be keeping it powered continuously, combine with a relay to create the circuit shown below: 8. the timer setting dial should only be turned within the range indicated on the dial face. turning it too far may break the stopper and cause damage to internal components. 12 v dc 24 v dc 100 to 120 v ac 200 to 240 v ac 500 v 4,000 v rt r r t please abide by the conditions below when using in applications that comply with en61812-1. 1. overvoltage category iii, pollution level 2 2. the load connected to the output contact should have basic insulation. this timer is protected with basic insulation and can be double- insulated to meet en/iec requirements by using basic insulation on the load. 3. please use a power supply that is protected by an overcurrent protection device which complies with the en/ iec standard (example: 250 v 1 a fuse, etc.). 4. you must use a terminal socket or socket for the installation. do not touch the terminals or other parts of the timer when it is powered. when installing or un-installing, make sure that no voltage is being applied to any of the terminals. 5. do not use this timer as a safety circuit. for example when using a timer in a heater circuit, etc., provide a protection circuit on the machine side. all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. features 1. 100-240v ac free-voltage input, 48-125v dc type available 2. short body ?62.5mm 2.461 inch (screw terminal type) 3. front panel of ip65 type is protected against water-splash and dust 4. built-in screw terminals screw terminal type is used for easy wiring and reducing additional cost for accessories. 5. 0 setting instantaneous output operation 6. multiple time ranges ?1 s to 500 h (max.) 7. 8 different operation modes: (pm4h-a) 8. compliant with ul/csa, ce and lloyd 48 1.890 48 1.890 62.5 2.461 mm inch pin type screw terminal type product types type pm4h-s pm4h-m pm4h-a operation mode contact arrangement time range rated operating voltage protective construction terminal type part number pm4ha-h-ac240vw pm4ha-h-ac240vsw pm4ha-h-dc125vw pm4ha-h-dc125vsw pm4ha-h-24vw pm4ha-h-24vsw pm4ha-h-dc12vw pm4ha-h-dc12vsw pm4ha-h-ac240v pm4ha-h-ac240vs pm4ha-h-dc125v pm4ha-h-dc125vs pm4ha-h-24v pm4ha-h-24vs pm4ha-h-dc12v pm4ha-h-dc12vs pm4hs-h-ac240vw pm4hs-h-ac240vsw pm4hs-h-dc125vw pm4hs-h-dc125vsw pm4hs-h-24vw pm4hs-h-24vsw pm4hs-h-dc12vw pm4hs-h-dc12vsw pm4hs-h-ac240v pm4hs-h-ac240vs pm4hs-h-dc125v pm4hs-h-dc125vs pm4hs-h-24v pm4hs-h-24vs pm4hs-h-dc12v pm4hs-h-dc12vs pm4hm-h-ac240vw pm4hm-h-ac240vsw pm4hm-h-dc125vw pm4hm-h-dc125vsw pm4hm-h-24vw pm4hm-h-24vsw pm4hm-h-dc12vw pm4hm-h-dc12vsw pm4hm-h-ac240v pm4hm-h-ac240vs pm4hm-h-dc125v pm4hm-h-dc125vs pm4hm-h-24v pm4hm-h-24vs pm4hm-h-dc12v pm4hm-h-dc12vs 16 selectable ranges 1s to 500h relay timed-out 1 form c instantaneous 1 form c relay timed-out 2 form c relay timed-out 2 form c 8 operation modes pulse on-delay pulse flicker pulse on-flicker differential on/off-delay (1) (2) signal off-delay pulse one-shot pulse one-cycle power on-delay 5 operation modes (with instantaneous contact) power on-delay power flicker power on-flicker power one-shot power one-cycle 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 11 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 8 pins screw terminal 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc 100 to 240v ac 48 to 125v dc 24v ac/dc 12v dc ip65 ip50 ip65 ip50 ip65 ip50 if you use this timer under harsh environment, please order above sealed type (ip65 type). ip65 type ?protection dust and water jet splay on the front face. ul file no.: e122222 csa file no.: lr39291 pm4h-a/s/m din48 size multi-range analog timer pm4h-a pm4h-s pm4h-m rohs directive compatibility information http://www.nais-e.com/ all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. specifications pm4h-a type item pm4h-s 100 to 240v ac, 48 to 125v dc, 12v dc, 24v ac/dc rated operating voltage 50/60hz common (ac operating type) 5a 250v ac (resistive load) power on-delay pulse on-delay pulse flicker pulse on-flicker differential on/off-delay (1) (2) signal off-delay pulse one-shot pulse one-cycle power on-delay power flicker power on-flicker power one-shot power one-cycle (with instantaneous contact) rated frequency rated control capacity 1s to 500h (max.) 16 time ranges switchable 0.3% (power off time change at the range of 0.1s to 1h) 5% (full-scale value) 0.5% (at the operating voltage changes between 85 to 110%) max. 100m ? (at 1a 6v dc) 2% (at 20 c ambient temp. at the range of ?0 to +50 c +14 to +122 f ) timed-out 1 form c instantaneous 1 form c time range operating time fluctuation 2 10 7 10 5 (at rated control capacity) mechanical (contact) electrical (contact) 85 to 110% of rated operating voltage (at 20 c coil temp.) allowable operating voltage range ?0 to +50 c +14 to +122 f ambient temperature 30 to 85%rh (at 20 c 68 f , non-condensing) ambient humidity 860 to 1,060hpa atmospheric pressure 20% ripple factor (dc type) ip65 on front panel (using rubber gasket atc18002) pm4h-a/s/m t erminal layouts and wiring diagrams pm4h-a pin type timed-out 2 form c screw terminal type timed-out 2 form c pm4h-m pin type timed-out 1 form c instantaneous 1 form c screw terminal type timed-out 1 form c instantaneous 1 form c pm4h-s pin type timed-out 2 form c screw terminal type timed-out 2 form c 2) contact 3) voltage should not be applied to the various inputs (reset, start, and stop) of the pm4h-a multi-range timer. these inputs should be input without voltage. timed-out contact instantaneous contact type pm4h-a pm4h-s pm4h-m pin connect the terminal to negative (?, and the terminal to positive (+). connect the terminal x to negative (?, and the terminal z to positive (+). connect the terminal to negative (?, and the terminal to positive (+). screw terminal 1) dc type start input reset input n.o. n.c. n.c. 3 5 4 2 1 11 10 9 8 7 6 stop input n.o. (? (+) operating voltage n.c. n.o. n.c. n.o. 54321 109876 11 (? (+) operating voltage stop input reset input start input (? (+) n.c. n.c. n.o. n.o. operating voltage 8 5 1 7 6 2 3 4 n.c. n.o. n.c. n.o. 54321 109876 11 (? (+) operating voltage (? (+) n.c. n.c. n.o. n.o. operating voltage 8 5 1 7 6 2 3 4 n.c. n.o. n.c. n.o. 54321 109876 11 (? (+) operating voltage par ts name pm4h-s pm4h-a pm4h-m time range selector 16 time settings selectable (1 s to 500 h) 1s 5s 10s 50s 1min 5min 10min 50min 1h 5h 10h 50h 10h 50h 100h 500h power indicator led time indicator window time unit indicator output indicator led hand operation mode selector selectable from 8 operation modes on : pulse on-delay fl : pulse flicker fo : pulse on-flicker of1 : differential on/off-delay (1) sf : signal off-delay os : pulse one-shot of2 : differential on/off-delay (2) oc : pulse one-cycle set dial operation mode indicator instantaneous output area when the hand is in this area, instantaneous operation starts. operation mode selector selectable from 5 operation modes on : power on-delay fl : power flicker fo : power on-flicker os : power one-shot oc : power one-cycle all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. pm4h-a/s/m dimensions mm inch tolerance: 0.5 .020 pm4h- screw terminal type (flush mount) panel mount dimensions (with mounting frame) screw terminal type surface mount dimensions pin type panel cut out dimensions standard cut out dimensions are shown below. use mounting frame (at8-da4) and rubber gasket (atc18002). adjacent mounting pin type pin type (flush mount/surface mount) note) 1. the proper thickness of mounting panel is between 1 to 5mm. 2. adjacent mount is less water-resis- tant. 62.5 2.461 12.0 .472 .236 6.0 48 1.890 48 1.890 44.5 1.752 41 dia. 1.614 dia. 1 .039 48 1.890 61.5 2.421 48 1.890 44.5 1.752 50 1.969 66 2.598 rubber gasket atc 18002 (attached) mounting frame at8-da4 (attached) panel 48 1.890 48 1.890 50 1.969 66 2.598 72.5 2.854 (8-pin) 78 3.071 (11-pin) rubber gasket atc18002 mounting frame at8-da4 (sold separately) rear terminal socket at78041 (8-pin: sold separately) at78051 (11-pin: sold separately) panel din rail socket at8-df8k (8-pin: sold separately) at8-df11k (11-pin: sold separately) mounting rail at8-dla1 104.0 (11-pin) 4.094 97.3 (8-pin) 3.831 45 + 1.772 +.024 0 0.6 0 45 + 1.772 +.024 0 0.6 0 min. 80 3.150 min. 80 3.150 a 45 + 1.772 +.024 0 0.6 0 a = (48 n?.5) + a = (1.890 n?098) +.024 0 0.6 0 14.5 66.5 2.618 48 1.890 44.5 1.752 41 dia. 1.614 dia. 48 1.890 12.0 .472 .236 6.0 all rights rese r v ed c o p y r i gh t matsushita elect r ic w o r k s , ltd. pm4h-a/s/m operation mode pm4h-a note: keep 0.1s or more for power off time. keep 0.05s or more for start, stop, reset input time. operation type explanation time chart ?if using a time-limit start when the power is turned on, and a reset when the power is turned off, pins 2 to 6 (screw-tightening pins x and c ) should be shorted ahead of time. ?turn the operation mode selector switch to the position. if pins 2 to 6 (screw-tightening pins x and c ) are shorted (the start input is turned on) with the power supply on, the output will go on after the set time has elapsed. if the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to v ) are shorted (the reset input is turned on), a reset is carried out. note) during time-limited operation, the time-limited operation is stopped while the pins 2 to 5 (screw-tightening pins x to b ) are being shorted (the stop input is on). when the pins are released, time-limited operation resumes. ?turn the operation mode selector switch to the position. when pins 2 to 6 (screw-tightening pins x and c ) are shorted (the start input is turned on) with the power supply on, the output goes on, and when pins 2 to 6 (screw-tightening pins x and c ) are released (the start input is turned off), the time limit interval begins. after the set time has elapsed, the output goes off. if start input is entered at any point during the time limit interval, the time limit interval is reset. note) during time-limited operation, the time-limited operation is stopped while the pins 2 to 5 (screw-tightening pins x to b ) are being shorted (the stop input is on). when the pins are released, time-limited operation resumes. ?turn the operation mode selector switch to the position. when pins 2 to 6 (screw-tightening pins x and c ) are shorted (the start input is turned on) with the power supply on, the output goes on, and after the set time has elapsed, it goes off. also, when pins 2 to 6 are released (the start input goes off), the output goes on, and after the set time has elapsed, it goes off. if the status of pins 2 to 6 (screw-tightening pins x and c ) changes dur- ing the time-limit interval (the start input goes from on to off, or from off to on), the time-limit interval is restarted from the point at which the change took place. if the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to v ) are shorted (the reset input is turned on), a reset is carried out. note) during time-limited operation, the time-limited operation is stopped while the pins 2 to 5 (screw-tightening pins x to b ) are being shorted (the stop input is on). when the pins are released, time-limited operation resumes. ?if using a time-limit start when the power is turned on, and a reset when the power is turned off, pins 2 to 6 (screw-tightening pins x and c ) should be shorted ahead of time. ?turn the operation mode selector switch to the position. when pins 2 to 6 (screw-tightening pins x and c ) are shorted (the start input is turned on) with the power supply on, the output goes on, and after the set time has elapsed, it goes off. this process is subsequently repeated. if the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to v ) are shorted (the reset input is turned on), a reset is carried out. note) during time-limited operation, the time-limited operation is stopped while the pins 2 to 5 (screw-tightening pins x to b ) are being shorted (the stop input is on). when the pins are released, time-limited operation resumes. ?if using a time-limit start when the power is turned on, and a reset when the power is turned off, pins 2 to 6 (screw-tightening pins x and c ) should be shorted ahead of time. ?turn the operation mode selector switch to the position. when pins 2 to 6 (screw-tightening pins x and c ) are shorted (the start input is turned on) with the power supply on, the limited time interval begins, and the output goes on after the set time has elapsed. after the output has gone on, it goes off when the set time has elapsed, and this process is sub- sequently repeated. if the power supply is turned off, or pins 2 to 7 (screw-tightening pins x to v ) are shorted (the reset input is turned on), a reset is carried out. note) during time-limited operation, the time-limited operation is stopped while the pins 2 to 5 (screw-tightening pins x to b ) are being shorted (the stop input is on). when the pins are released, time-limited operation resumes. pulse on-delay on on pulse flicker fl fl pulse on-flicker fo fo differential on/off-delay (1) of1 of1 signal off-delay sf sf pow er supply on off start on off on on off reset on off stop on off time out (n.o. contact) op. led power led on tt 1 t 2 on offoff note: led lighting or no led lighting pow er supply on off start on off on off on off off reset on stop on off time out (n.o. contact) op. led power led on tt t 1 t a t 2 t b on offoff note: led lighting or no led lighting pow er supply on off start on off on off on off off reset on stop on off time out (n.o. contact) op. led power led on tt t 2 tt a t b t 1 offoff pow er supply on off start on off on off on reset stop on off time out (n.o. contact) op. led power led on on tt 1 t 2 t a t b off off on off restart off note: led lighting or no led lighting pow er supply on off start on off on off on off on reset stop time out (n.o. contact) op. led power led on tt b t a off off note: led lighting or no led lighting led lighting led flickering t: setting time t 1 , t 2 , t a , t b |