www.pairuigroup.com page: 1/3 date: 12/13/2013 dc-dc converter sip-package dbv-1 series, 1watt, regulated with 2:1 input range features: 3 years warranty 1500vdc isolation voltage wide (2:1) input voltage range regulated isolated twin output models operating temperature range -40c to +85c continuous short circuit protection model input voltage (vdc) output voltage (vdc) output current (ma) efficiency typ. min. max. dbv1-0501 5(4.5~9) 5, 5 10 100 80% DBV1-0502 9, 9 5.5 55 80% dbv1-0503 12, 12 4.0 40 80% dbv1-0504 15, 15 3.3 33 80% dbv1-0505 24, 24 2.1 21 80% dbv1-1201 12(9~18) 5, 5 10 100 80% dbv1-1202 9, 9 5.5 55 80% dbv1-1203 12, 12 4.0 40 80% dbv1-1204 15, 15 3.3 33 80% dbv1-1205 24, 24 2.1 21 80% dbv1-2401 24(18~36) 5, 5 10 100 80% dbv1-2402 9, 9 5.5 55 80% dbv1-2403 12, 12 4.0 40 80% dbv1-2404 15, 15 3.3 33 80% dbv1-2405 24, 24 2.1 21 80% notes: other input and output models may available on reques t. electrical line regulation --- 0.2% load regulation 10% ~ 100% full load 0.5% ripple and noise --- 100mvp-p max. isolation voltage --- 1500vdc short circuit protection --- continuous short circuit protection operating temperature range --- -40c to +85c mtbf --- 1x10 6 hrs notes: all the data in this article are under test with ta+25 c, humidity<75%, rated input and rated load mode.
www.pairuigroup.com page: 2/3 date: 12/13/2013 dc-dc converter sip-package dbv-1 series, 1watt, regulated with 2:1 input range mechanical connection pin # isolated twin 1 gnd 2 +vin 6 +vo1 7 -vo1 8 cs 9 -vo2 10 +vo2 note: * unit is mm(inch). temperature profile capacitive loads selection vin (vdc) cin (f) single output voltage (vdc) cout (f) dual output voltage (vdc) cout (f) 5 4.7-100 5 560 5 270 12 4.7-100 9 470 9 220 24 4.7-100 12 470 12 220 - - 15/24 330 15/24 150/100
www.pairuigroup.com page: 3/3 date: 12/13/2013 dc-dc converter sip-package dbv-1 series, 1watt, regulated with 2:1 input range notes recommended test and application circuit in order to ensure the efficiency and dependability of the mo dule, the minimum specified load must be less than 10% of rated load. if the output power is low, we recommend to add an e xternal 10% loading resistor in parallel. fuse: depends on the actual input current; tvs: depends on the actual input voltage; recommended capacitor:c1, c2, c5,about 0.1uf; for c6,c7,c 9, please check the capacitive load; c3,c4:2kv/1nf.
|