panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t types *indicate the peak ac and dc values. note: the surface mount terminal indicator ? and the packing style indicator ? or ? are not marked on the device. rating both low on-resistance and good cost-performance achieved. he 1 form a (aqv25 ? ) i/o isolation output rating* pac kage part no. pac king quantity through hole terminal surface-mount terminal load voltage load current tube packing style tape and reel packing style tube tape and reel picked from the 1/2/3-pin side picked from the 4/5/6-pin side ac/dc dual use 1,500v 40 v 500 ma dip6-pin aqv251 aqv251a aqv251ax aqv251az 1 tube contains: 50 pcs. 1 batch contains: 500 pcs. 1,000 pcs. 60 v 400 ma aqv252 aqv252a aqv252ax aqv252az 100 v 350 ma aqv255 aqv255a aqv255ax aqv255az 200 v 250 ma aqv257 aqv257a aqv257ax aqv257az 250 v 200 ma aqv253 AQV253A AQV253Ax AQV253Az 400 v 150 ma aqv254 aqv254a aqv254ax aqv254az 1,000 v 30 ma aqv259 aqv259a aqv259ax aqv259az 1,500 v 20 ma aqv258 aqv258a aqv258ax aqv258az reinforced 5,000v 250 v 200 ma aqv253h aqv253ha aqv253hax aqv253haz 400 v 150 ma aqv254h aqv254ha aqv254hax aqv254haz 600 v 130 ma aqv256h aqv256ha aqv256hax aqv256haz testing (reinforced type, excluding aqv256h) (standard type) mm inch 8.8 6.4 3.9 8.8 6.4 3.6 .346 .252 .154 .346 .252 .142 1 2 3 6 5 4 rohs compliant features 1. wide variation of 40v, 60v, 100v, 200v, 250v, 400v, 600v, 1,000v and 1,500v load voltage 2. low on-resistance of typ. 0.6 ? (aqv251) 3. reinforced insulation type of 5,000v i/o isolation available typical applications ?measuring instruments ?data communication equipment ?telephone equipment ?automatic meter reading device height includes standoff ne w 1. absolute maximum ratings (ambient temperature: 25 c 77 f ) item sym- bol t ype of connec- tion aqv251(a) aqv252(a) aqv255(a) aqv257(a) aqv253(a) aqv254(a) aqv259(a) aqv258(a) aq v253h(a) aqv254h(a) aqv256h(a) remarks input led forward current i f 50 ma led reverse voltage v r 5 v peak forward current i fp 1 a f = 100 hz, duty factor +0.1% pow er dissipation p in 75 mw output load voltage (peak ac) v l 40v 60v 100v 200v 250v 400v 1,000v 1,500v 250v 400v 600v continuous load current i l a 0.5a 0.4a 0.35a 0.25a 0.2a 0.15a 0.03a 0.02a 0.2a 0.15a 0.13a a connection: peak ac, dc b, c connection: dc b 0.7a 0.6a 0.45a 0.35a 0.3a 0.18a 0.04a 0.025a 0.3a 0.18a 0.14a c 1.0a 0.8a 0.70a 0.5a 0.4a 0.25a 0.05a 0.04a 0.4a 0.25a 0.16a peak load current i peak 1.8a 1.5a 1.0a 0.75a 0.6a 0.5a 0.09a 0.06a 0.6a 0.5a 0.4a a connection: 100 ms (1 shot) v l = dc pow er dissipation p out 360 mw total power dissipation p t 410 mw i/o isolation voltage v iso 1,500 v ac 5,000 v ac temperature limits operating t opr ?0 c to +85 c ?0 f to +185 f non-condensing at low temperatures storage t stg ?0 c to +100 c ?0 f to +212 f
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t 2. electrical characteristics (ambient temperature: 25 c 77 f ) *turn on/turn off time recommended operating conditions please obey the following conditions to ensure proper device operation and resetting. for dimensions . for s c hematic and wiring di a grams . for cautions f or us e . these products are not designed for automotive use. if you are considering to use these products for automotive applications, please contact your local panasonic corporation technical representative. for more in f ormation . continual dc bias (for aqv258 ?? , a qv259 ?? ) in cases in which a continual dc bias is applied between the input and output, the output-side mos-fet may deteriorate due to the voltage. therefore, please verify operation of the actual design before using. an example of a circuit that might undergo mos-fet deterioration due to voltage is given below. item sym- bol t ype of con- nection a qv251(a) aqv252(a) aqv255(a) aqv257(a) aqv253(a) aqv254(a) aqv259(a) aqv258(a) aq v253h(a) aqv254h(a) aqv256h(a) condition input led operate current typical i fon 0.9 ma 1.4 ma i l = max. maximum 3 ma led turn off current minimum i foff 0.4 ma i l = max. typical 0.8 ma 1.3 ma led dropout voltage typical v f 1.25 v (1.14 v at i f = 5 ma) i f = 50 ma maximum 1.5 v output on resistance typical r on a 0.6 ? 0.74 ? 1.8 ? 2.6 ? 5.5 ? 12.4 ? 85 ? 345 ? 5.5 ? 12.4 ? 20 ? i f = 5 ma i l = max. within 1 s on time maximum 1 ? 1.4 ? 2.5 ? 4 ? 8 ? 16 ? 200 ? 500 ? 8 ? 16 ? 30 ? typical r on b 0.3 ? 0.37 ? 0.9 ? 1.4 ? 2.7 ? 6.2 ? 60 ? 345 ? 2.7 ? 6.2 ? 15 ? i f = 5 ma i l = max. within 1 s on time maximum 0.5 ? 0.7 ? 1.25 ? 2 ? 4 ? 8 ? 100 ? 500 ? 4 ? 8 ? 20 ? typical r on c 0.15 ? 0.18 ? 0.45 ? 0.7 ? 1.4 ? 3.1 ? 30 ? 160 ? 1.4 ? 3.1 ? 7.5 ? i f = 5 ma i l = max. within 1 s on time maximum 0.25 ? 0.35 ? 0.63 ? 1 ? 2 ? 4 ? 50 ? 250 ? 2 ? 4 ? 10 ? off state leakage current maximum i leak ? a 10 a1 a i f = 0 ma v l = max. tr ansfer characteristics tu rn on time* typical t on 1.7 ms 1.4 ms 0.9 ms 1.5 ms 0.8 ms 0.6 ms 0.35 ms 2.4 ms 1.8 ms 1.2 ms i f = 5 ma i l = max. maximum 3 ms 2 ms 3 ms 2 ms 1 ms 4 ms 3ms tu rn off time* typical t off 0.07 ms 0.09 ms 0.1 ms 0.06 ms 0.05 ms 0.04 ms 0.06 ms 0.05 ms 0.06 ms i f = 5 ma i l = max. maximum 0.2 ms i/o capacitance typical c iso 1.3 pf f = 1 mhz v b = 0 v maximum 3 pf initial i/o isolation resistance minimum r iso 1,000 m ? 500 v dc item symbol recommended value unit input led current i f standard type: 5 reinforced insulation type: 5 to 10 ma ton input output 10% 90% toff
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t reference data 1.-(1) load current vs. ambient temperature characteristics allowable ambient temperature: ?0 c to +85 c ?0 f to +185 f ; type of connection: a 1.-(2) load current vs. ambient temperature characteristics allowable ambient temperature: ?0 c to +85 c ?0 f to +185 f ; type of connection: a 2.-(1) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: max. (dc) 0 0.2 0.4 0.6 0.1 0.3 0.5 aqv257 aqv253(h) aqv254(h) aqv256h aqv251 aqv252 aqv255 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 100 load current, a aqv259 aqv258 ambient temperature, c load current, ma 0 20 30 50 10 40 -40 -20 0 2 0 4 0 6 0 8085 100 0 0.5 2.0 2.5 1.0 1.5 aqv255 4.0 3.5 4.5 5.0 3.0 aqv252 aqv251 aqv257 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 on resistance, ? 2.-(2) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: max. (dc) 2.-(3) on resistance vs. ambient temperature characteristics measured portion: between terminals 4 and 6; led current: 5 ma; continuous load current: 30 ma (dc) 3.-(1) turn on time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 0 15 10 20 25 5 35 40 30 aqv253(h) aqv254(h) aqv256h ambient temperature, c on resistance, ? -40 -20 0 2 0 4 0 6 0 8085 0 100 200 300 aqv258 400 500 aqv259 ambient temperature, c on resistance, ? -40 -20 0 2 0 4 0 6 0 8085 0 2 4 1 3 aqv251 aqv252 aqv257 aqv253 aqv254 aqv255 aqv259 aqv258 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu r n on time, ms 3.-(2) turn on time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 4.-(1) turn off time vs. ambient temperature characteristics led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 4.-(2) turn off time vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h led current: 5 ma; load voltage: max. (dc); continuous load current: max. (dc) 0 2 5 1 3 aqv253h aqv254h aqv256h 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu r n on time, ms 0 0.2 0.3 0.4 0.1 aqv251,aqv252,aqv255 aqv253,aqv257 aqv259,aqv258 aqv254 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu rn off time, ms 0 0.2 0.3 0.5 0.1 0.4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 tu rn off time, ms 5.-(1) led operate current vs. ambient temperature characteristics sample: aqv251, aqv252, aqv253, aqv254, aqv255, aqv258, aqv259; load voltage: max. (dc); continuous load current: max. (dc) 5.-(2) led operate current vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h; load voltage: max. (dc); continuous load current: max. (dc) 6.-(1) led turn off current vs. ambient temperature characteristics sample: aqv251, aqv252, aqv253, aqv254, aqv255, aqv258, aqv259; load voltage: max. (dc); continuous load current: max. (dc) 0 2 3 4 1 ambient temperature, c led operate current, ma -40 -20 0 2 0 4 0 6 0 8085 0 2 3 5 1 4 ambient temperature, c led operate current, ma -40 -20 0 2 0 4 0 6 0 8085 0 2 3 1 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 led turn off current, ma
panasonic corporation automation controls business unit industrial.panasonic.com/ac/e he 1 form a (aqv25 ? ) asctb143e 201201-t 6.-(2) led turn off current vs. ambient temperature characteristics sample: aqv253h, aqv254h, aqv256h; load voltage: max. (dc); continuous load current: max. (dc) 7. led dropout voltage vs. ambient temperature characteristics led current: 5 to 50 ma 8.-(1) current vs. voltage characteristics of output at mos portion measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 0 2 3 5 1 4 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 led turn off current, ma 0 1.0 1.1 1.2 1.3 1.4 50ma 30ma 20ma 10ma 5ma 1.5 ambient temperature, c -40 -20 0 2 0 4 0 6 0 8085 100 led dropout voltage, v aqv251 aqv252 aqv255 aqv257 aqv253(h) aqv254(h) aqv256h 3.0 2.52.01.51.00.5 -0.5-1.0-1.5-2.0-2.5-3.0 -0.1 -0.2 -0.3 -0.4 -0.5 -0.6 0.6 0.5 0.4 0.3 0.2 0.1 v oltage, v current, a 8.-(2) current vs. voltage characteristics of output at mos portion measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 9-(1). off state leakage current vs. load voltage characteristics sample: aqv259; measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f 9-(2). off state leakage current vs. load voltage characteristics measured portion: between terminals 4 and 6; ambient temperature: 25 c 77 f aqv259 aqv258 40 30 20 10 v oltage, v current, ma -40 -30 -20 -10 8642 -8 -6 -4 -2 100806040200 10 ? 10 ? 10 ? 10 ?2 load voltage, v off state leakage current, a aqv254h aqv256h load voltage, v off state leakage current, a 100806040200 10 ? 10 ? 10 ? 10 ?2 10-(1). turn on time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 10-(2). turn on time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 11-(1). turn off time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 0 0.5 1.0 1.5 2.0 3.0 aqv253,aqv254,aqv257,aqv255 2.5 aqv252 aqv251 aqv259 aqv258 led current, ma tu r n on time, ms 6050403020100 0 2 4 6 8 12 10 aq v253h aqv256h aqv254h led current, ma tu r n on time, ms 6050403020100 0 0.02 0.04 0.08 0.06 0.12 aqv251,aqv252,aqv255 0.10 aqv253,aqv257 aqv254 aqv259,aqv258 led current, ma 50403020100 tu rn off time, ms 11-(2). turn off time vs. led forward current characteristics measured portion: between terminals 4 and 6; load voltage: max. (dc); continuous load current: max. (dc); ambient temperature: 25 c 77 f 12.-(1) output capacitance vs. applied voltage characteristics measured portion: between terminals 4 and 6; frequency: 1 mhz; ambient temperature: 25 c 77 f 12.-(2) output capacitance vs. applied voltage characteristics sample: aqv259; measured portion: between terminals 4 and 6; frequency: 1 mhz; ambient temperature: 25 c 77 f aqv253h,254h,aqv256h tu rn off time, ms 0 0.02 0.04 0.08 0.06 0.12 0.10 led current, ma 50403020100 0 100 200 600 300 400 500 6050403020100 output capacitance, pf applied voltage, v aqv251,aqv252 aqv253(h),aqv254(h),aqv257 0 20 40 120 60 80 100 aqv259 aqv256h 6050403020100 output capacitance, pf applied voltage, v
|