cpv series ? phase control modules ? 120/240 vac models ? 0-5 v dc phase control ? used with series 1 random-fire solid-state relays product selection description 10 a 25 a 50 a 75 a 90 a 120 vac 10CPV120 25cpv120 50cpv120 75cpv120 90cpv120 240 vac 10cpv240 25cpv240 50cpv240 75cpv240 90cpv240 output specifications (voltage) (1) description 120 vac 240 vac operating voltage (47-63hz) [vrms] 90-140 vac 180-280 vac transient overvoltage [vpk] 400 600 maximum off-state leakage current @ rated voltage [marms] 10 10 minimum off-state dv/dt @ maximum rated voltage [v/sec] (2) 500 500 output specificatio ns (current) (1) description 10 a 25 a 50 a 75 a 90 a maximum load current (3) [arms] 10 25 75 50 90 minimum load current [arms] 0.04 0.04 0.04 0.04 0.04 maximum surge current (16.6ms) [apk] 120 250 625 1000 1200 maximum on-state voltage drop @ rated current [vpk] 1.6 1.6 1.6 1.6 1.6 thermal resistance juncti on to case (rjc) [c/w] 1.48 1.02 0.31 0.63 0.28 maximum i2t for fusing (8.3 msec) [a2 sec] 60 260 4150 1620 6000 minimum power factor (with maximum load) 0.5 0.5 0.5 0.5 0.5 control module inpu t specificat ions (1) description dc control control voltage range 0-5 vdc minimum turn-off voltage 1.0 vdc typical supply current 1.6 ma @ 5 vdc nominal control input impedance 1500 ohm maximum turn-on time [msec] 0.02 maximum turn-off time [msec] 1/2 cycle control module output spec ifications (t erminal 4b - inpu t to relay) (1) description dc control maximum off-state operating voltage 36 vdc maximum load current (sink) 3.0 ma maximum on-state voltage @ 3 ma 0.5 vdc max. off state leakage @ 10 vdc 1.0 adc general specifications description parameters dielectric strength, signal to load 4000 vrms dielectric strength, signal to base 4000 vrms ambient operating temperature range -30 to 80c ambient storage temperature range -40 to 125c weight (typical) 3.0 oz. (43g) encapsulation themally conductive epoxy for contact information visit our web site. www.crydom.com ? 2008 cryd om, inc. specifications subject to change without notice. obsolete
general notes 1) all parameters at 25c unless otherwise spec ified. 2) off-state dv/dt test method per eia/narm standard rs-443, paragraph 13.11.1 3 ) heat sinking required (relay only), see derating curves. available options cpv120 control module only (120 vac line) cpv240 control module only (240 vac line) wiring diagram agency approval rev. 0827 09 for contact information visit our web site. www.crydom.com ? 2008 cryd om, inc. specifications subject to change without notice. obsolete
for contact information visit our web site. www.crydom.com ?2008 cryd om, inc. specifications subject to change without notice.
annex - enviromental information for contact information visit our web site. www.crydom.com ?2008 cryd om, inc. specifications subject to change without notice.
|