  data sheet fxj, fxk stop valve & condensate chamber application: the stop valve is used to remove a trans- mitter from a pressure piping when main- tenance of the transmitter is required. it can be readily fitted to the pressure piping. material of main unit: materials of other parts: operating pressure and temperature: type of connection: mass {weight}: fxja 0.5kg fxjc, d 2kg fxjk 3kg fxjf,g,h,j 3.5kg finish color: silver (excluding sus parts) range of delivery: stop valve operating pressure and temperature, and material: 2mpa?50 c max., jis stpg370 {20.39kgf/cm 2 } 6mpa?00 c max., jis stpt370 {61.18kgf/cm 2 } 15mpa?00 c max., astm a182 f11 {153.0kgf/cm 2 } 24mpa?25 c max., astm a182 f22 {244.7kgf/cm 2 } type of connection: r1/2 rc1/2 1/2b pipe 1/2b socket 1/2, 1b flange (jis 10, 16, 20, 30k) note: for the arrang ement of inlet and outlet, refer to table given in page 2 water inlet: pressure: 6mpa{61.18kgf/cm 2 } max. for standard provision pressure: 15mpa{153.0kgf/cm 2 } min. for non-standard provision application: the condensate chamber is used with a differential pressure transmitter when measuring boiler drum level or stream flow rate. it keeps condensation at a fixed level for better measurement accuracy. inlet outlet application rc1/2 rc1/2 22.2 socket rc1/2 9.6 union 22.2 socket fxja, c, d, k fxja, c, d fxjf, g, j, h in measuring pressures, flow rates or levels, a process piping and a pressure piping to feed pressures from a process tank to a transmitter are required. fuji's stop valve and condensate chamber are designed to be used with a pressure piping system to provide proper maintenance of transmitters and better measurement accuracy. both the stop valve and condensate chamber are available in different operating pressure ratings to permit selection according to applications. note: symbols a to k denote the 4th digit of the code. 200 250 250 425 525 360 425 300 temperature [ c]max. symbol fcd400 fcd450 sus304 astm a182f11 astm a182f22 sf440a sf440a sus304 material of main unit materials of other parts sus 403 sus 304 sus 304 sus 403 sus 403 sus 403 sus 403 sus 304 operating pressure 1mpa{10.20kgf/cm 2 } 2mpa{20.39kgf/cm 2 } 2mpa{20.39kgf/cm 2 } 15mpa{153.0kgf/cm 2 } 24mpa{244.7kgf/cm 2 } 11mpa{112.2kgf/cm 2 } 28mpa{285.5kgf/cm 2 } 7mpa{71.38kgf/cm 2 } a c d f g h j k * * specifications stop valve (type:fxj) condensate chamber (type:fxk) ranges of operating temperature and pressure date EDS8-42H may. 30, 2000
fxj, fxk 2 arrangement of the 5th and 6th digits of the code following the symbol in the 4th digit abcde fghj fig.no. 1 2 3 4 a b c f g h k l m a c d e h j m n e e fig. 6 fig. 7, 8 fig. 9, 10 fig. 11 fig. 12 fig. 13, 14 fig. 15, 16 fig. 17 fig. 18 4th digit 5th digit 6th digit code symbols stop valve condensate chamber 12345678 9 description fxj 3 material/pressure connection screw, rc1/2 union socket treatment none oil repulsion (sus304 only) stainless steel tag plate none yes a c d f g h j k 10 20 30 * * y a y a materials of other parts operating pressure temperature [ c]max connection fcd400 fcd450 sus304 astma182f11 astma182f22 sf440a sf440a sus304 sus403 sus304 sus304 sus403 sus403 sus403 sus403 sus304 1mpa {10.20kgf/cm 2 } 2mpa {20.39kgf/cm 2 } 2mpa {20.39kgf/cm 2 } 15mpa {153.0kgf/cm 2 } 24mpa {244.7kgf/cm 2 } 11mpa {112.2kgf/cm 2 } 28mpa {285.5kgf/cm 2 } 7mpa {71.38kgf/cm 2 } 200 250 250 425 525 360 425 300 rc1/2 rc1/2 rc1/2 1/2 socket ( 22.2) 1/2 socket ( 22.2) 1/2 socket ( 22.2) 1/2 socket ( 22.2) rc1/2 material of main unit 1234567 y a 8 description fxk 3 material, pressure and temperature type of connection (1) type of inlet is entered in the 5th digit of the code, and the type of outlet in the 6th digit. (2) symbols entered in the 5th and 6th digits are referred to table given below. r1/2 rc1/2, with union joint (screw type) rc1/2, with socket (screw type) 1/2b pipe (welded to socket) 1/2b, with sockert (welded to socket) jis 10k 15a, with flange jis 16k 15a, with flange jis 20k 15a, with flange jis 30k 15a, with flange jis 10k 25a, with flange jis 16k 25a, with flange jis 20k 25a, with flange jis 30k 25a, with flange other stainless steel tag plate none yes 1 2 3 4 a b c d e f g h j k l m n z end plate operating pressure temperature [ c]max stpg370 stpt370 astm a182 f11 astm a182 f22 sphc-p sf440a 2mpa {20.39kgf/cm 2 } 6mpa {61.18kgf/cm 2 } 15mpa {153.0kgf/cm 2 } 24mpa {244.7kgf/cm 2 } 350 400 500 525 drum
3 stop valve outline diagram (unit:mm)
fxj, fxk 4 condensate chamber
5
fxj, fxk asterisked (*) items: non-standard. information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS8-42H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X