power entry modules with line filter dd 2 www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole, line switch 2-pole standard- or medical-filter c14 70 c description - panel mount: screw-on from front side - 4 functions: appliance inlet protection class i, line switch 2-pole, fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, line filter in standard and medical version - quick connect terminals 6.3 x 0.8 mm approvals - vde certificate number: 40001522 - ul file number: e72928 characteristics - ultra-compact design. ideal for low profile designs aluminum case provides good shielding - all single elements are already wired - fuse drawer meets requirements of medical standard iec/en 60601-1 the fuseholder is accessible from the equipment front for added safety "extra-safe" fuse drawers are available - ideal for application with high transient loads designed for standard and medical applications - qualified for use in equipment according iec/en 60950 other versions on request - solder terminals - fuse drawer 1-pole, plus spare fuse case - fuse drawer 2-pole, with shorting bar - other rocker marking - line switch, illuminated - line switch 1-pole - medical version m80 - class x1- and y1-capacitors for enhanced withstand voltage - protection class ii, 70c references alternative: version without line filter dd1 1 alternative: version for snap-in mounting km f weblinks general product informatio n , approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor-stock- chec k , accessorie s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 8 a @ ta 40 c / 250 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (1 min/50 hz) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 6.3 x 0.8 mm panel thickness s screw-on mounting: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1 ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 2 w (1 pole)/ 1.6 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch rocker switch 2-pole, non-illuminated, acc. to iec 61058-1 technical detail s line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 2'000'000 h acc. to mil-hb-217 f
2 power entry modules with line filter dd 2 www.schurter.com/pg0 6 emc products dimensions 55.4 mm screw version 46.7 31.5 27.7 3.25 10.3 56 66 0.10 12 90? 45.3 9.8 3.4 55 5.9 29.8 56 49.3 0.15 0.10 r 4.6 0.10 3.4 pe n 15.1 1.3 48.5 l technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 100 2.2 1 2 standard version 2 x 4 100 2.2 1 4 standard version 2 x 1.5 100 2.2 1 6 standard version 2 x 0.8 100 2.2 1 8 standard version 2 x 0.6 100 2.2 1 10 standard version 2 x 0.3 100 2.2 1 1 medical version (m5) 2 x 10 100 - 1 2 medical version (m5) 2 x 4 100 - 1 4 medical version (m5) 2 x 1.5 100 - 1 6 medical version (m5) 2 x 0.8 100 - 1 8 medical version (m5) 2 x 0.6 100 - 1 10 medical version (m5) 2 x 0.3 100 - 1 diagrams standard version non illuminated 1) line 2) load medical version m5 non illuminated 1) line 2) load derating curves 1-pole admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c 2-pole admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.6 0.6 0.4 0.8 1.2 1.0 1.4 ambient air temperature ta c
power entry modules with line filter dd 2 www.schurter.com/pg0 6 emc products attenuation loss . . . . . 0.1/100 ? differential mode ........... 100/0.1 ? differential mode - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 8 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 8 a 10 a variants fuse drawer must be ordered separately (see accessories). fingergrip and extra safe. the same drawer as used by type kea. rated current [a] filter-type fuseholder line switch order number 1 standard version 1-pole 2-pole dd12.1111.111 2 standard version 1-pole 2-pole dd12.2111.111 4 standard version 1-pole 2-pole dd12.4111.111 6 standard version 1-pole 2-pole dd12.6111.111 8 standard version 1-pole 2-pole dd12.8111.111 10 standard version 1-pole 2-pole dd12.9111.111 1 standard version 2-pole 2-pole dd12.1121.111 2 standard version 2-pole 2-pole dd12.2121.111 4 standard version 2-pole 2-pole dd12.4121.111 6 standard version 2-pole 2-pole dd12.6121.111 8 standard version 2-pole 2-pole dd12.8121.111 10 standard version 2-pole 2-pole dd12.9121.111 1 medical version (m5) 2-pole 2-pole dd12.1321.111 2 medical version (m5) 2-pole 2-pole dd12.2321.111 4 medical version (m5) 2-pole 2-pole dd12.4321.111 6 medical version (m5) 2-pole 2-pole dd12.6321.111 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 100 2.2 1 2 standard version 2 x 4 100 2.2 1 4 standard version 2 x 1.5 100 2.2 1 6 standard version 2 x 0.8 100 2.2 1 8 standard version 2 x 0.6 100 2.2 1 10 standard version 2 x 0.3 100 2.2 1 1 medical version (m5) 2 x 10 100 - 1 2 medical version (m5) 2 x 4 100 - 1 4 medical version (m5) 2 x 1.5 100 - 1 6 medical version (m5) 2 x 0.8 100 - 1 8 medical version (m5) 2 x 0.6 100 - 1 10 medical version (m5) 2 x 0.3 100 - 1
power entry modules with line filter dd 2 www.schurter.com/pg0 6 emc products rated current [a] filter-type fuseholder line switch order number 8 medical version (m5) 2-pole 2-pole dd12.8321.111 10 medical version (m5) 2-pole 2-pole dd12.9321.111 10 a version only approved up to 8 a at ul. packaging unit 20 pcs required accessor y description fusedrawer 2 fusedrawer with and without voltage selector insert fingergrip, 2-pole 4301.1401 extra-safe, 2-pole 4301.1403 fingergrip, 1-pole 4301.1405 extra-safe, 1-pole 4301.1407 ... accessorie s assorted cover s rear cover 0859.0076 cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outletoverview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outletfurther types todd1 2 connectoroverview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connectorfurther types todd1 2 ...
power entry modules with line filter dd 2 www.schurter.com/pg0 6 emc products category / description power cordoverview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cordfurther types todd1 2 ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|