49 visit www.lairdtech.com for product additions and more product details cc2824 surface mount cc1812 surface mount can-bus common mode chokes features: ? accurate current matching capability over a broad range of inductance values ? sector wound coils at 25 & 51 h to flter differential mode noise from the data signal. ? low distortion ? custom designs possible ? open bottom case construction ? small ( 1812 ) size parts are also available. ? surface mount applications: ? automotive controller area network systems ? industrial controls controller area network systems ? medical monitoring systems ? filtering common mode emi on high speed differential lines such as network and telecom applications operating temperature range: -40c to +125c (0c to 125c for lp > 1000 m m) part number lp inductance (mh) peak impedance ( z ) l leakage (mh) hi-pot ( vac ) 0.5 ma 2 sec. dcr typical ( w ) ldc (ma) test conditions min nom max cc1812c513r-10* 100 khz / 50 mv 35.7 51.0 66.3 3500 w @40 mhz 2.60 250 0.50 200 cc2824j502r-10 100 khz / 50 mv 3.5 5.0 6.5 400 w @500 mhz 0.05 250 0.10 1200 cc2824e113r-10 100 khz / 50 mv 7.7 11.0 14.3 800 w @200 mhz 0.05 250 0.12 800 cc2824e253r-10 100 khz / 50 mv 17.5 25.0 32.5 2000 w @100 mhz 1.50 250 0.13 800 cc2824e513r-10* 100 khz / 50 mv 35.0 51.0 66.3 3800 w @50 mhz 2.00 250 0.16 800 CC2824E474R-10 100 khz / 50 mv 329.0 470.0 611.0 8600 w @5 mhz 0.20 750 0.20 700 cc2824e105r-10 100 khz / 50 mv 700.0 1000.0 1500.0 4250 w @7 mhz 0.20 750 0.20 700 cc2824d225r-10 10 khz / 50 mv 1540.0 2200.0 3300.0 5300 w @5 mhz 0.25 750 0.40 500 cc2824b475r-10 10 khz / 50 mv 3290.0 4700.0 7050.0 12300 w @2 mhz 0.30 750 0.55 400 part number a mm (inches) b mm (inches) c mm (inches) cc2824 7.50 max (0.295 max) 5.50 max (0.217 max) 3.80 max (0.150 max) cc1812 5.00 max (0.197 max) 3.50 max (0.138 max) 5.55 max (0.140 max) part number system example cc 1812 c 513 r -10 product series code part size code rated current code impedance value code packaging code additional description these current compensating surface mount common mode chokes can be used in controller area networks (can-bus) in automotive, industrial and medical applications. a b c a b c refer to part print for specifc dimensions * sector wound
50 cc2824j502r-10 cc2824e113r-10 frequency (mhz) 1000 cc1812c513r-10, cc2824e513r-10 cc2824e253r-10 100 10 1 0 frequency (mhz) -2 -4 -6 -8 -10 -12 -14 -16 1000 100 10 1 frequency (mhz) 1000 100 10 1 0.1 cc2824d225r-10 frequency (mhz) 1000 100 10 1 il (db) 0 -5 -10 -15 -20 -25 -30 -35 il (db) 0 -5 -10 -15 -20 -25 -30 il (db) -40 cc2824e471r-10 cc2824e105r-10 frequency (mhz) 1000 100 10 1 0 -5 -10 -15 -20 -25 -30 il (db) 0 -5 -10 -15 -20 -25 -30 il (db) -35 frequency (mhz) 1000 100 10 1 0 -5 -10 -15 -20 -25 il (db) frequency (mhz) 1000 100 10 0.1 0 -5 -10 -15 -20 -25 -30 il (db) -35 1 cc2824b475r-10 0 -5 -10 -15 -20 -25 -30 -35 il (db) -40 frequency (mhz) 100 10 1 0.1 -45 typical insertion loss @ 50 w
|