  specification TN-1500-112 tn-1500 -124 tn-1500 -148 tn-1500 -212 tn-1500 -224 tn-1500 -248 200 / 220 / 230 / 240vac selectable by setting button s.w 50 0.1%hz 50/60hz selectable by setting button s.w 75a 24v 21 ~ 30vdc 89% 37.5a 48v 42 ~ 60vdc 90% 75a 24v 21 ~ 30vdc 90% 37.5a 48v 42 ~ 60vdc 91% model waveform output frequency ac regulation (typ.) transfer time (typ.) front panel indicator saving mode (typ.) no load dissipation bat. voltage off mode draw current voltage range (typ.) note.1 efficiency (typ.) note.2 dc current (typ.) note.5 input input protection battery output fuse safety & emc bat. low alarm bat. low shutdown over temperature output short reverse polarity gfci proctection 100 / 110 / 115 / 120vac selectable by setting button s.w 1725w for 180 sec. / 2250w for 10 sec. / surge power 3000w for 30 cycles true sine wave (thd<3%) at rated input voltage 60 0.1hz 50/60hz selectable by setting button s.w 150a 12v 10.5 ~ 15vdc 88% 40a*5 30a*3 30a*2 30a*2 30a*3 11.3 4% 22.5 4% 45 4% 45 4% 22.5 4% 10.5 4% 21 4% 42 4% 42 4% 21 4% 3.0% 10ms inverter by pass default disabled. load 5w will be changed to standby mode battery voltage level, output load level, saving mode, fault and operat ion status 18w @ standby saving mode 12v 1ma 10.5 ~ 15vdc 87% 150a 40a*5 11.3 4% 10.5 4% 82 5 protection type : shut down o/p voltage, re-power on to recover ; by internal r th3 detect on heatsink of power transistor protection type : shut down o/p voltage, re-power on to recover 82 5 96 5 68 5 68 5 68 5 by internal fuse open optional (only type f) none 10a compliance to fcc class a none working temp. note.3 working humidity storage temp., humidity lvd safety standards 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o none en60950-1 compliance to en61000-4-2,3,4,5,6,8,11 compliance to en55022 class b, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) u.p.s. mode and energy saving mode (selectable) power on-off switch standby saving mode can be selectable front panel indicator for operation status thermostatically controlled cooling fan protections: bat. low alarm / bat. low shutdown / over voltag e / over temp. / output short / input polarity reverse / overload / ac circui t breaker application : home appliance, power tools, office and porta ble equipment, vehicle and yacht ...etc. built-in solar / ac charger optional monitoring software 3 years warranty high surge power up to 3000w high efficiency up to 91% rated power (typ.) 1500w battery types open & sealed lead acid over load (typ.) circuit breaker 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover 20a withstand voltage bat i/p - ac i/p:3.0kvac bat i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes ul458 (only for "gfci" receptacle-type f ) features : 1500w true sine wave dc-ac inverter with solar charger t n - 1 5 0 0 s e r i e s max open circuit voltage charge current (typ.) charge current (max.) charge voltage charge voltage 25v 5.5a 30a 14.3v 4 % 14.3v 4 % solar charger ac charger 28.5v 4 % 28.5v 4 % 2.7a 75v 57v 4% 57v 4 % 1.35a none 45v 28.5v 4 % 28.5v 4 % 2.7a 75v 57v 4 % 57v 4 % 1.35a 14.3v 4 % 14.3v 4 % 5.5a 45v 25v others packing 6.85kg; 2pcs/14.7kg/1.61cuft dimension control wiring 420*220*88mm (l*w*h) rj11 -rs232 (option) file name:tn-1500-spec 2011-05-24 note 1.output derating capacity referenced by curve 1.2.efficiency is tested by 1000w, linear load at 13v, 26v, 52v input voltage. 3.output derating capacity referenced by curve 2. 4.all parameters not specified above are measured at rated load, 25 of ambient temperature. 5.dc current is tested by 1500w, linear load at 13v, 26v, 52v input voltage. ac voltage factory setting set at 110vac factory setting set at 230vac protection environment maximum output power (typ.) e 13 emc immunity emc emission
inverter tn v.1.1 1. installation of tn-1500 unit and pc 2. explanation of monitoring manu 2.1 main page figure 2 1. setting: adjustment for output voltage, charging related voltag e, frequency, and operation mode. please refer to figure 3 for details. 2. statistics: calculate for the percentage of operating period for ea ch operation mode. please refer to figure 4 for details. 3. r.c. power off: power can be turned on or off at the remote location. 4. pause: stop refreshing the page of monitoring software. 5. status of unit: indicating current operating status of tn-1500. 6. signals that display current condition of the unit. db9 female figure 1 16 phone jack rj11 rj11 pin no. db9 pin no. 23 35 42 1 2 3 4 6 7 8 9 5 setting solar charge 1 2 3 4 5 6 inverter ac charge 100 100 0 0 battery voltage o/p voltage internal temperature by pass tn-1500-143 utility voltage start date reset date o/p frequency power on remote off battery low battery used up stand by saving mode abnormal shutdown battery loading 54.1 110 10.0 0.0 2007/12/07 03:13:33 pm 2007/12/21 01:40:56 pm 60.0 v v v hz ac in statistics r.c. power off pause exit file name:tn-1500-spec 2011-05-24 1500w true sine wave dc-ac inverter with solar charger t n - 1 5 0 0 s e r i e s instructions for tn-1500 monitoring software
inverter setting inverter setting 2.2 setting page 2.3 statistic page figure 3 figure 4 1. user can adjust the settings based on the characteristics of batteries b een used: equalization voltage, floating voltage, alarm voltage, and shut-down voltage. ups mode / energy saving mode selection and ac outp ut voltage and frequency can also be set in this page. 2. read: read current settings of the unit. 3. write: write the revised setting into the unit. 4. load: load in factory default settings. 1. start date: date that installing the monitoring software. 2. reset date: date that resetting the statistics. the start date will not b e influenced by resetting the statistics or turning off the unit. 3 .inverter time rate: operating period of "inverter mode" represents h ow many percent of the whole operating period. 4. bypass time rate: operating period of "bypass mode" (energy provides d irectly by the utility) represents how many percent of the whole operating period. 5. shut down rate: percentage of time period that the unit is under the conditi on of shut down. 6. solar time rate: percentage of time period that the solar charger is funct ioning after turning on the tn-1500 unit. 7. loading average: average loading after turning on the tn-1500 unit . * inverter time rate + bypass time rate + shut down rate = 100% 1 file name model name manufacture series number date of manu. revision i/o type bauds rate equalization volt. floating volt. alarm volt. shutdown volt. voltage frequency stand-by saving mode ups mode energy saving mode d:\tn_110rr\20071205\rev\tn_110rr\tnf\tn_1k5_512.tn f start date start date 2007/12/07 03:13:33 pm 2007/12/21 01:40:56 pm inverter time rate inverter time rate bypass time rate bypass time rate shut down rate shut down rate solar time rate solar time rate loading average loading average 91.2 31.9 0.0 0.0 8.8 68.1 0.0 0.0 24.7 63.7 % % % % % % % % % % tn-1500-212 meanwell loc-1234567890 rev:1.10 212 9600 14.3 13.3 11.3 10.5 v 13.5 ~ 15.0v 13.0 ~ 13.5v 11.0 ~ 11.5v 10.0 ~ 11.0v vv v 230 v 50 1 read write lead exit read ok!! hz on on on comm ports 2 3 4 off 06/23/2007 1500w true sine wave dc-ac inverter with solar charger t n - 1 5 0 0 s e r i e s file name:tn-1500-spec 2011-05-24 exit reset
mechanical specification derating curve unit:mm curve 1 curve 2 ambient temperature ( ) 0 10 20 30 40 50 60 70 20 40 60 80 100 battery input voltage (v) 10.5vdc 21vdc 42vdc 11.5vdc 23vdc 46vdc 15vdc 30vdc 60vdc 20 40 60 80 100 (horizontal) load (%) load (%) file name:tn-1500-spec 2011-05-24 1500w true sine wave dc-ac inverter with solar charger t n - 1 5 0 0 s e r i e s a :type a outlet b :type b outlet c :type c outlet d :type d outlet e :type e outlet f :type f outlet +ac charger and solar charger true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:1500w tn 1500 112 a type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci (expect for 48v input) ac output receptacles (optional) 207 type-a type-b 220 203.2 108.4 88 44.25 22 15.6 11.05 20 27.45 36.25 57.75 7 12.1 47 + - + - + - 48 10 air flow direction 420 ac input chassis ground reverse polarity will damage the unit. solar input (30a max) neg pos dc input cat.no.(1gg1hs-212) wire range(10-4 awg str cu soldered wires) torque (17.7-26.5 in lb) ac output solar charge ac charge battery 100 0 100 0 saving bat low on setting load inverter by pass ac in on off c i r c u i t b r e a k e r p r e s s t o r e s e t remote port ac output solar charge ac charge battery 100 0 100 0 saving bat low on setting load inverter by pass ac in on off c i r c u i t b r e a k e r p r e s s t o r e s e t remote port e 13 e e 13 13


▲Up To Search▲   

 
Price & Availability of TN-1500-112

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X