  portaflow-c is a portable type ultrasonic flowmeter utilizing the transit time measuring method, using a clamp- on type detector. it is a compact and lightweight instrument incorporating the latest electronics and digital signal processing technologies, realizing high performance and easy operation. features 1. compact and lightweight the adoption of the latest electronics and digital signal processing technologies has reduced the size and weight of the flow transmitter by 30% and 30%, respectively, in comparison with the fuji conventional portable flowmeter (model fsc). (in comparison to our existing model) 2. battery operation the flowmeter is designed for 12 hours of continu - ous operation via built-in battery which is recharge - able in 3 hours with the exclusive power adapter. 3. full variety of detectors the flowmeter is suitable for various types of detec - tors applicable for small to large diameter pipe (pipe inner diameter 13 to 6000mm) and low to high temperature (?40 to +200c). 4. high accuracy and high-speed response the flowmeter is designed for high accuracy (1.0%). response time is within 1 second. 5. improved anti-bubble characteristic anti-bubble characteristic is greatly improved by digital signal processing. 6. excellent performance and easy operation large graphic lcd that is outside but easy to read. minimum number of function keys are used for page selection, allowing easy setting. while battery is working, the flowmeter is water resistant and tolerates exposure to rain. 7. large capacity storage by sd memory card measured data is periodically stored in sd memory card. for example, in the case of 256mb (option), it can be saved about 1 year measurement date(in case of saving period 30 seconds, 14 kinds of saved data). available up to 8mb. 8. serial communication use of a usb port allows easy connection to a per - sonal computer. measured date collection panel and loader software for pc (standard) which is available for display and change of parameter (site setting) are prepared. 9. heat quantity (calorie) measurement heat quantity (calorie) may be measured by tem - perature input, making energy management easy for cooling and heating. 10. graphic printer connection (option) easy recording with the integral type printer. 11. flow velocity profile measurement (option) flow profile may be observed in real time. specifications measuring objects measurement fluid: uniform liquid in which ultrasonic waves can propagate. turbidity of fluid: 10000 mg/l or less state of fluid: well-developed turbulent or laminar flow in a filled pipe. fluid temperature: ?40 to +200c measuring range: 0 0.3 to 32m/s piping conditions applicable piping material: select from carbon steel, stainless steel, cast iron, pvc, frp, copper, aluminum, acrylic or material of known sound velocity. pipe size: flow rate measurement 13 to 6000mm flow velocity profile measurement 40 to 1000mm data sheet fsc, fsd EDSX6-139H jul. 22, 2011 date ultrasonic flowmeter (portaflow-c) portable type flow transmitter (fsc) detector for high-temperature(fsd) detector for transit time(fsd)
lining material: select from no lining, tar epoxy, mortar, rubber, teflon, pyrex glass or material of known sound velocity. note) no gap allowed between the lining and the pipe. straight pipe length: 10d or more upstream and 5d or more downstream (d: internal pipe diam - eter) refer to japan electric measuring in - struments manufactures associations standard jemis-032 for details. performance specifications accuracy rating: pipe inner diameter flow velocity range accuracy 13 to 50mm 2 to 32m/s 1.5% of rate 0 to 2m/s 0.03m/s 50 to 300mm 2 to 32m/s 1.0% of rate 0 to 2m/s 0.02m/s 300 to 6000mm 1 to 32m/s 1.0% of rate 0 to 1m/s 0.01m/s note) reference conditions are based on jemis-032. flow transmitter (type: fsc) power supply: built-in battery or ac power adapter built-in battery: exclusive lithium button battery (5000m ah) continuous operation time, approx. 12 hours (without printer, back light off, output current not used and at normal ambient temperature (20c)) recharging time, approx. 3 hours (power adapter used) recharging temperature range: 0 to +40c power consumption: min. 3w and max. 16w the consumption varies depending on the use conditions. power adapter: exclusive power adapter 90v to 264v ac (50/60hz), 70va or less. lcd: semi-transmissive color graphic dis - play 240 320 (with back light) measurement value (instantaneous flow rate, integrated flow rate) and various settings are displayed. excellent visibility even outdoors in direct sunlight. led display: status display when using ac power adapter. dc in (green): power supply status charge (red): battery charging under - way operation keypad: 11 buttons (on, off, ent, esc, menu, ? , ? , ? , ? , light, print) power failure backup: measurement value is backed up by nonvolatile memory. clock backup with lithium battery (ef - fective term, 10 years or more) response time: 1 second analog output signals: 4 to 20ma dc, one point (load resis - tance, 600 ? or less) instantaneous velocity, instantaneous flow rate or heat quantity (calorie) after scaling. analog input signal: 4 to 20ma dc, one point (input resistance, 200 ? or less) 4 to 20ma dc, one point (in - put resistance, 200 ? or less) or 1 to 5v dc, one point used to input temperature for heat quantity measurement, etc. sd memory card: used for data logger function and recording screen data. available up to 8gb (option256mb) compliant media ? sd memory card: speed class 2, 4, 6 ? sdhc memory card: speed class 4, 6 format ? fat16: 64mb to 2gb ? fat32: 4gb, 8gb otherwise, reading and saving are impossible. file format ? date logger: csv file ? screen date: bit map file serial communication: usb port (device* compatible): mini b receptacle connectable number of mini b recep - tacles: 1 unit transmission distance: 3m max. transmission speed: 500kbps data: instantaneous velocity, instanta - neous flow rate, total value, heat quantity (calorie) value, error infor - mation, logger data, etc. * device: connected plug from pc printer (option): to be mounted on top of transmitter unit thermal line dot printing note) when the chinese display is selected, printing is made in kanji characters. ambient temperature: ?10 to +55c (without printer) ?10 to +45c (with printer) ambient humidity: 90%rh or less type of enclosure: ip64 (without printer) enclosure case: plastic case outer dimensions: h210 w120 d65mm (without printer) h320 w120 d65mm (with printer) weight: 1.0kg (without printer) 1.2kg (with printer) various functions display language: selectable from japanese, english, german, french, spanish or chinese (switchable by key operation). clock display function: time (year, month, day, hour, minute) display (configurable) monthly error: about 1 minutes at nor - mal temperature (20c). total 2 points 2 fsc, fsd
instantaneous value display function: instantaneous velocity, instantaneous flow rate display (the flow in reverse direction is displayed with minus ?.) numeric value: 10 digits (decimal point equals 1 digit) unit: metric/english system selectable metric system velocity: m/s flow rate: l/s, l/min, l/h, l/d, kl/d, ml/d, m 3 /s, m 3 /min, m 3 /h, m 3 /d, km 3 /d, mm 3 /d, bbl/s, bbl/min, bbl/h, bbl/d, kbbl/d, mbbl/d english system velocity: ft/s flow rate: gal/s, gal/min, gal/h, gal/d, kgal/d, mgal/d, ft 3 /s, ft 3 /min, ft 3 /h, ft 3 /d, kft 3 /d, mft 3 /d, bbl/s, bbl/min, bbl/h, bbl/ d, kbbl/d, mbbl/d total value display function: display of forward or reverse total (reverse is displayed as minus) numeric value: 10 digits (decimal point is corresponding to 1 digit) unit: metric/english system selectable metric system flow rate total: ml, l, m 3 , km 3 , mm 3 , mbbl, bbl, kbbl english system flow rate total: gal, kgal, ft 3 , kft 3 , mft 3 , mbbl, bbl, kbbl, acre-ft consumed heat quantity (calorie) display function: display of consumed heating medium metric system heat flow: mj/h, gj/h total heat quantity: mj, gj english system heat flow: mj/h, gj/h, btu/h, kbtu/h, mbtu/h, kwh, mwh total heat quantity: mj, gj, btu, kbtu, mbtu, kw, mwh j : joule btu : british thermal unit w : watt computation function of consumed heat quantity (calorie): this function calculates the heat quantity received and sent with liquid (water) in cooling and heating. heat source heat exchanger detector (type : fsd) temperature sensor temperature sensor consumed heat quantity q = k q (t1Ct2) k : heat quantity (calorie) conversion factor (for heating k = 4.123, for cooling = 4.186) q: flow rate of the fluid t2: fluid temperature (outlet) t1: fluid temperature ( inlet) converter converter temperature display function: fluid temperature be displayed by cur - rent input from temperature transmit - ter. metric system temperature unit: c or k english system temperature unit: f or k site data storage function: max. 32 locations (sites) data (pipe size, material, fluid type and etc) can be stored into built-in non-volantile memory. damping: 0 to 100sec (every 0.1sec) configurable for analog output and velocity/flow rate display low flow cut: equivalent to 0 to 5m/s output setting function: current output scaling, output type, burnout setting and calibration serial communication function: instantaneous velocity, instantaneous flow rate, total value, heat flow, er - ror information, received waveform, analog input, velocity profile data, logger data, etc. may be downloaded to personal computer. logger function: instantaneous velocity, instantaneous flow rate, total value, heat flow, error information, received waveform, ana - log input, velocity profile date can be saved in a sd memory card. waveform display function: bi-directional received waveforms may be displayed. graph display function: flow rate trend graph may be dis - played. printing function (option): hard copy output of a screen periodic printing (type: text, graph) logger date (type: text, graph) flow velocity profile measurement (option): flow velocity profile may be observed in real time using the exclusive detec - tor (option). (refer to page 5 for details.) detector (type: fsd) type of detector: kind type internal pipe diameter (mm) fluid temperature small diameter fsd22 13 to 100 ?40 to 100c small type fsd12 50 to 400 ?40 to 100c middle type fsd41 200 to 1200 ?40 to 80c large type fsd51 200 to 6000 ?40 to 80c high temperature fsd32 50 to 400 ?40 to 200c mounting method: mounting on outside of pipe sensor mounting method: v or z method signal cable: exclusive coaxial cable standard 5m (included with fsd41, 51 and fsd32) 3
plastic wedge pzt oscillator pipe lining cable detector 4 to 20ma dc flow transmitter cable detector flow transmitter 4 to 20ma dc mounting of detector (2) when z method is used for mounting measuring principle with ultrasonic pulses propagated diagonally between the upstream and downstream sensors, flow rate is measured by detecting the time difference obtained by the flow of fluid. configuration diagram (1) when v method is used for mounting upstream sensor flow velocity v downstream sensor t 1 t 2 detector d flow trans- mitter output signal detector selection guide fsd41 (middle type) z v v fsd12 (small type) fsd51 (large type) v fsd32 (high-temperature) z v z ?40 to 80 ?40 to 100 ?40 to 200 13 25 50 100 200 300 400 1000 3000 6000 250 type (name) fluid temperature [c] mounting method 300 50 fsd22 (small diameter) v ?40 to 100 100 13 50 150 400 z 150 400 250 200 400 1200 200 3000 6000 200 600 inner diameter of piping ? (mm) *2) *1) ?40 to 80 *1) *1) when fsd12 or fsd32 is mounted using the z-size method, guide rail (option) is required additionally. *2) for the pipe inner diameter of 13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness. when the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%. required min. pipe thickness (fluid: water) (unit: mm) steel pipe stainless pipe pvc pipe copper pipe cast-iron pipe aluminum pipe 2.15 or more 1.87 or more 3.69 or more 3.82 or more 2.98 or more 1.99 or more frp ductile cast iron peek pvdf acrylic pipe polypropylene 3.21 or more 2.15 or more 3.69 or more 3.69 or more 2.90 or more 3.69 or more it shows pipe thickness of each material that the sensor mounting size is to be 0.0mm, when fixing a pipe. if the fluid is the one other than water, and if the sound velocity of fluid is faster than the one of water, the sensor mounting size is to be 0.0mm or more. method for connection: flow transmitter side exclusive connector detector side large/middle type: screw terminal others: bnc connector ambient temperature: ?20 to +60c ambient humidity: large/middle type sensor: 100%rh or less others: 90%rh or less type of enclosure: large/middle type sensor: ip67 others: ip52 material and mounting belt/wire: kind type sensor case mounting bracket mounting belt /wire s m a l l d i a m - eter fsd22 plastic aluminum alloy + plastic plastic cloth belt small type fsd12 plastic aluminum alloy + plastic plastic cloth belt middle type fsd41 plastic sus304 stainless wire large type fsd51 plastic ?? stainless wire high tempera - ture fsd32 sus304 aluminum alloy + sus304 stainless belt extension cable (option): extended when the length of the de - tector signal cable is not sufficient. length: 10m, 50m 4 fsc, fsd
flow velocity profile display function (option) flow velocity profile can be observed in real time using the dedicated detector from the outside. it is specifiable by the code symbol of flow transmitter. application pulse doppler method is applicable to observe flow velocity profile in real time, display the flow status in the pipe, and decide the appropriate measurement location. also, it can be used for diagnosis of flow and laboratory test. specifications measuring fluid: uniform liquid in which ultrasonic waves can propagate. turbidity of fluid: axisymmetric flow in a filled pipe. fluid temperature: ?40 to +100c (fsdp2) ?40 to +80c (fsdp1,fsdp0) air bubble quantity: 0.02 to 15vol% (velocity is 1m/s) pipe size: small type sensor : 40 to 200mm middle type sensor : 100 to 400mm large type sensor : 200 to 1000mm measurement range: 0 to 0.3: maximum velocity (de - pending on the pipe diameter) refer to chart, table.1. note) this function is to observe flow velocity profile, and it may be different from actual flow rate. detector for flow velocity profile measurement (type: fsdp) mounting method: mounting on outside of existing pipe ambient temperature: ?20 to +80c ambient humidity: 100% rh or less type of enclosure: ip67 (with waterproof bnc connector provided.) material: sensor housing: pbt guide frame: aluminum alloy mounting belt: plastic cloth belt/stain - less belt (1) using one sensor block diagram measurement principle ? ultrasonic pulses are transmitted through the fluid flow. entrained bubbles and microscopic particles within the fluid create frequency phase shifts (doppler effect.) the resulting doppler shifts are integrated across the inside pipe diameter cross section. the resulting profile curve is a real-time dynamic display of the flow profile within the pipe. (2) using two sensors sensor 1 (fsd) sensor 2 (fsd) flow reflection air bubbles flow velocity piping wall center piping wall flow velocity profile 2 flow velocity profile 1 power supply sensor (fsd) cable flow transmitter sensor (fsd) sensor (fsd) cable power supply flow transmitter the above shows an example when using two sensors. one detector displays the flow velocity profile for a ra - dius. 5
code symbol pc loader software equipped as standard ? pc/at compatible machines. (operation on custom built pcs or shop-brand pcs cannot be guaranteed.) ? major functions: performs parameter (site setting) display /change of the main unit and collects measured date. instantaneous velocity, instantaneous flow rate, total value, error information, received waveform, analog input, logger data, etc. may be downloaded in a personal computer. ? o/s: windows2000/xp/vista* ? memory requirement: 128mb or more ? disk unit: windows2000/xp/vista-compatible cd-rom drive ? hard disk drive capacity: free space of 64mb or more * windows vista: use it in basic mode. it is not available for windows aero. unit: m/s unit: m 3 /h diameter 50a fsdp2 6.52 fsdp1 fsdp0 65a 5.31 80a 4.65 90a 4.12 100a 3.69 3.08 2.63 2.04 7.25 125a 6.08 150a 5.20 200a 4.05 3.30 2.78 2.51 2.20 7.77 250a 6.38 300a 5.41 350a 4.90 400a 4.31 450a 3.80 500a 3.48 550a 3.17 600a 2.91 650a 2.71 700a 2.52 750a 2.35 800a 2.21 850a 2.08 900a 1.97 1000a 1.77 fsdp2 52.7 40a 6.56 33.6 fsdp1 fsdp0 72.1 86.5 102 118 147 179 239 231 289 354 474 604 735 820 951 908 1168 1428 1598 1858 2118 2358 2618 2879 3096 3357 3618 3879 4140 4400 4902 1 0 f s c description 1 2 3 4 5 6 7 8 - 9 10 11 standard basic system basic system + printer none provided (detector to measure flow velocity profile is separately required.) ac power + power cord (125v ac) for japanese and north american use ac power + power cord (250v ac) for european and korean use ac power + power cord (250v ac) for chinese use modification no. none provided (256mb) none (factory-set language: english) provided/japanese (factory-set language: japanese) provided/english (factory-set language: english) provided/chinese (factory-set language: chinese) (note1) instruction manual contained in cd is the standard attached article. (note2) you can change the language by key operation. s 1 0 1 a b c 0 1 1 2 y j e c table.1 maximum measurement range of pulsed doppler method. when nominal thickness of a stainless pipe of pipe material is sch20s and the fluid is water, the maximum measurement range varies depending on the outer diameter of pipe, nominal thickness, material, or flu id type. 6 fsc, fsd
(for flow velocity profile measurement) (for transit time) f description s d 0 y 1 1 2 3 4 5 6 7 8 small type ( 40 to 200mm) middle type ( 100 to 400mm) large type ( 200 to 1000mm) general use p p p 2 1 0 0 y < terminal mold> none 1 modification no. f description s d 1 2 3 4 5 6 7 8 small type (for 50 to 400mm) * 1) * 2) small diameter (for 13 to 100mm) middle type (for 200 to 1200mm) large type (for 200 to 6000mm) high-temperature (for 50 to 400mm) * 1) * 2) general use 1 2 4 5 3 2 2 1 1 2 0 1 y < terminal mold> none provided (middle/large type only) 1 modification no. note) *1) applicable diameter range: v method: 50 to 250 (fsd32), 50 to 300 (fsd12) z method: 150 to 400 (fsd32, fsd12) use the optional guide rail, if a pipe that does not allow ultr asonic waves to pass through easily, such as when an old pipe, cast iron pipe or a pipe with mortar lining is used, or the flow or liquid high in turbidity is measured. employ the z method for mounting. optional items name specifications arrange- ment no. 1 battery special type li-ion battery (7.4v, 2500mah) zzp ? tk7n6384p1 2 ac power adapter special type power adapter and 90 to 264v ac, 50/60hz power connector conversion code zzp ? tk7n6380c4 3 power code japan, north america:125v ac 2m europe, korea: 250v ac 2m china: 250v ac 2m zzp ? tk7n6621p1 zzp ? tk7n6608p1 zzp ? tk7n6609p1 4 printer to be mounted on top of converter thermal serial dot system (8 x 384 dot) zzp ? tk4j2634c1 5 printer roll paper maker: seiko i supply co. ltd. type: tp-211c-1 specifications: thermal roll paper width: 58mm?48mm zzp ? tk7n6381p1 6 silicone grease maker: shin-etsu chemical co., ltd. type: for standard use g40m, 100g for high temperature ks62m, 100g zzp ? 45231n5 zzp ? tk7p1921c1 7 signal cable special type signal cable, 5m 2 fsd12, 22, 32 (connector on one side) fsd41 (connector on one side) fsd51 (connector on one side) zzp ? tk7n7795c1 zzp ? tk7n7795c2 zzp ? tk7n7795c3 8 bnc adapter bnc adapter (2) zzp ? tk7n6323p11 9 extension signal cable special type coaxial cable with bnc connector 10m 2 50m 2 zzp ? tk468664c3 zzp ? tk468664c4 10 analog input/output cable 6-core cable, 1.5m, with connector zzp ? tk4j2639c1 11 mounting belt /wire small type/small diameter sensor: plastic cloth belt large type sensor: stainless wire nominal diameter f200 to f500mm f200 to f1000mm f200 to f2000mm f200 to f3000mm f200 to f6000mm high-temperature sensor: stainless steel belt zzp ? tk7g7979c1 zzp ? tk7g7980c1 zzp ? tk7g7980c2 zzp ? tk7g7980c3 zzp ? tk7g7980c4 zzp ? tk7g7980c5 zzp ? tk7p1943c1 12 guide rail for high- temperature sensor (in mounting by the z method) mounting bracket material: aluminum alloy+sus304 fsd32 zzp ? tk4j5917c3 13 guide rail for small type detector (in mounting by the z method) mounting bracket material: aluminum alloy+plastic fsd12 zzp ? tk4j5917c1 14 sd memory card maker: apacer technology, inc. type: ap-esd256tpsr capacity: 256mb zzp ? tk7n6386p1 15 usb cable maker: sunwa supply inc. type: ku-amb510 specifications: mini usb cable (1.0m) zzp ? tk7n6622p1 scope of delivery name of unit scope of delivery 1 basic system 1) conversion unit 2) power adapter and power connector conversion cord 3) power cord 4) analog input/output cord (1.5m) 5) usb cable (1m) 6) carrying case 7) strap 8) special type signal cable (5m 2) 9) bnc adapter 10) cd-rom (instruction manual and loader software for pc) 2 option 1) printer unit + rolled paper (1 roll) 2) sd memory card (256mb) 3) bound instruction manual (including a detector) name of unit scope of delivery 1 detector for propa - gation time differ - ence (fsd) 1) sensor unit 2) signal cable (5m) (included with fsd41, 51) 3) mounting belt/wire 4) silicone grease (100g) 2 detector for flow v e l o c i t y p r o f i l e (fsdp) 1) detector unit 2) mounting belt/wire 3) silicone grease (100g) note 1) silicon grease is for filling a gap between a detector and a pipe joint area. it is provided with a detector. since silicon grease does not become hardened, if you use it in the long term, periodic maintenance is required. (under the condition of room temperature, semiannual cleaning and refill is recommended.) note 2) when you order a detector alone, an instruction manual is not provided. please request, if necessary. 7
conditions on straight pipe detector flow controlled upstream flow controlled downstream 1.5d or more d check valve p isolation valve 90 bend tee diffuser contraction pipe valve pump note) source: japan electric measuring instruments manufacturers' association (jemis-032) type length of upstream straight pipe length of downstream straight pipe (d: nominal diameter of pipe) 10d or more l 10d 0.5d or more 10d or more 10d or more l 50d l 30d l 10d l 30d l 50d l 10d l 50d l 5d l 10d l 5d diagram sd charge dc in feed portaflow esc on off print ent menu printer (option) detector detector exclusive use signal cable to connect signal cables for fsd12, fsd22, fsd32, fsdp2, fsdp1, fsdp0 to connect signal cables for fsd41 fsd51 bnc connector bnc connector bnc adaptor signal cable ao analog output 4 to 20ma dc aich1 analog input 4 to 20ma dc or 1 to 5 v dc aich2 analog input 4 to 20ma dc analog input/output cable ac90 to 264v power cord ac power adaptor power connector conversion cord to connect pc pc flow transmitter usb cable sd memory card for use ac adaptor detector input (the downstream side) detector input (the upstream side) 8 fsc, fsd
outline diagram (unit:mm) flow transmitter weight : approx. 1.0kg feed dc12v ai/ao upstream downstream sensor portaflow power switch dc power input analog input/output sensor (upstream) sensor (downstream) 2-m4, depth5 (both sides) usb port sd memory card slot charge dc in ent on off print esc menu 1201.8 2102.5 651.8 9
outline diagram (unit:mm) flow transmitter (with printer) weight : approx. 1.2kg charge dc in feed portaflow dc12v ai/ao upstream downstream sensor ent on off print esc menu power switch usb port sd memory card slot dc power input analog input/output sensor (upstream) sensor (downstream) printer approx. 3204.5 651.8 1201.8 2-m4, depth5 (both sides) 10 fsc, fsd
outline diagram (unit:mm) weight : approx. 0.6kg connector scale (inch) scale (mm) cursor element holder lock nut saddle spacing: 0 to 133 name plate nn jodi 320 2 360.5 52.50.5 90max. detector fsd22 ( s mall diameter) lock nut element holder weight : approx. 0.8kg connector scale(inch
scale mm
cursor element holder lock nut saddle spacing: 0 to 348 name prate 540 2 36 0.5 90max. 52.5 0.5 detector fsd12 ( s mall type) detector fsd32 ( h igh-temperature) weight : approx. 1.3kg sensor mounting spring wire rope name plate bnc connector cable a 542 114  371 461 ?19 ?4.3 500 0 +200 0 8 8.5 to flow transmitter + g connection diagram detector fsd41 ( m iddle type) cursor name plate 205max. 26 44 1 530 2 90max. 33 0.5 element holder lock nut saddle connector scale(inch) scale(mm) distance between two sensors 0 to 330 weight : approx. 1.7kg 11
fsc, fsd printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east t ower , 1 1-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www .fjielectric.com/products/instruments/ information in this catalog is subject to change without notice. outline diagram (unit:mm) weight : approx.2.2kg detector wire rope mounting spring name plate a bnc connector cable ?4.3 500 0 +200 0 8 8.5 ?19 672 781 922 114  detector fsd51 ( l arge type) detector fsdp (detector for flow velocity profile measurement) straight plug clip (?12.3) 1500 +100 -0 1005 (?5) ai ch2 ao ai ch1 weight : approx. 0.1kg code color clip color mark black (bk) red (r) (+) ao white (w) black (bk) (?) red (r) red (r) (+) ai ch1 green (g) black (bk) (?) yellow (y) red (r) (+) ai ch2 brown (bn) black (bk) (?) analog input/output cable mfd. type. ser.no. made in japan l bnc connector sensor unit absorber unit frame (h) w1 fsdp2 type fsdp1 40 to 200 2601.2 diameter (mm) l 100 to 400 2601.2 weight approx. (kg) 0.8 57 70 w h 57 72 0.9 fsdp0 200 to 1000 3502.0 85 90 2.0


▲Up To Search▲   

 
Price & Availability of EDSX6-139H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X