  filename: tfs 986a.doc version 1.0 10.05.2005 vi telefilter filter specification tfs 986a 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m measurement condition ambient temperature: 23 c input pow er level: 0 dbm terminating impedance: input: 50 ? output: 50 ? ch aracteristics remark: the minimum attenuation in the pass band is defined as the insertion loss a e . the nominal frequency f n is fix ed at 986,5 mhz w i thout any tolerance or limit. the v a lues of absolute attenuation a abs are guaranteed for the w hole operating temperature range. the frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. d a t a ty p. v a lue tolerance / limit insertion loss a e 1 , 4 d b m a x . 2 d b nominal frequency f n - 986,5 mhz passband - f n 15 mhz pass band ripple 0 , 7 d b m a x . 2 d b return loss w i thin pb 1 0 d b m i n . 7 d b a b solute attenuation a abs 0 , 3 m h z . . . 9 0 0 m h z 5 3 d b m i n . 5 0 d b 9 0 0 m h z . . . 9 4 0 m h z 5 0 d b m i n . 4 0 d b 9 4 0 m h z . . . 9 5 0 m h z 4 0 d b m i n . 2 5 d b 1 0 3 5 m h z ? 1 0 7 5 m h z 4 5 d b m i n . 2 5 d b 1 0 7 5 m h z ? 1 5 0 0 m h z 4 7 d b m i n . 4 0 d b input pow er lev e l ** - m a x . 2 1 d b m operating temperature range otr - - 30 c ...+ 70 c storage temperature range - - 40 c ... + 85 c temperature coefficient of frequency t c f * - 41 ppm/k - *) ? f c (hz) = tc f (ppm/k) x (t - t o ) x f cat (mhz). **) for 64qam signal ge ne ra te d: ch ecked / a p p r o v ed : vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 986a.doc version 1.0 10.05.2005 vi telefilter filter specification tfs 986a 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m f ilter ch aracteristic 700 80 0 90 0 1 000 1 100 12 00 130 0 140 0 150 0 -8 0 -7 0 -6 0 -5 0 -4 0 -3 0 -2 0 -1 0 0 f r e q uen c y i n m h z m agni t u de i n db 96 5 97 0 975 980 985 990 995 1000 1 005 -5 -4. 5 -4 -3. 5 -3 -2. 5 -2 -1. 5 -1 -0. 5 0 f r eq uenc y i n m h z m a gni t u d e i n db cons truc tion a nd pin c onne c t ion (all dimensions in mm) date code: y ear + w eek t 2005 u 2006 v 2007 ... 1 ground 2 input 3 ground 4 ground 5 output 6 ground 986a t20 50 ? t est circu i t l2 1, 3, 4, 6 5 2 vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 986a.doc version 1.0 10.05.2005 vi telefilter filter specification tfs 986a 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m stability characteristics after the follow i ng tests the filter shall meet the w hole specification: 1. shock: 500g, 18 ms, half sine w a ve, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respecti vely , 1 octave per min, 10 cy cles per plan, 3 plans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 10 cy cles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow ): reflow possible: tw ice max.; for temperature conditions refer to the attac hed "air reflow temperature conditions" on page 4; packin g tape & reel: iec 286 ? 3, w i th exeption of value for n and minimum bending radius; tape ty pe ii, embossed carrier tape w i th top cover tape on the upper side; max. pieces of filters peer reel: 9000 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao p u l l o ff d i r e c t i o n pi n m a r k e r t yp d a te c o d e ko t tape (al l di mensi ons i n mm) w : 8,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 3,50 0,05 g(min) : 0,75 p2 : 2,00 0,05 p1 : 4,00 0,1 d1(min) : 1,50 a o : 3,25 0,1 bo : 3,25 0,1 ct : 5,5 0,1 a c n w 1 w 2 r eel (all d i men s io n s in mm) a : 330 w 1 : 8,4 + 1 ,5/-0 w 2 (max ) : 14,4 n(min) : 50 c : 13,0 +0,5/-0,2 the minimum bending radius is 45 mm. vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 986a.doc version 1.0 10.05.2005 vi telefilter filter specification tfs 986a 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m a i r re flow te mpe r a t ure c onditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/second > 100c betw een 300 and 600 seconds > 150c betw een 240 and 500 seconds > 217c betw een 30 and 150 seconds peak temperature max. 260c time w i thin 5c of actual peak temperature betw een 10 and 30 seconds cool-dow n rate (peak to 50c) less than 6c/second time from 30c to peak temperature no greater than 300 seconds chip-mount air reflow profile temperature / c max. 260c 217c time / s max. 300 s 10 ... 30 s 30 ... 150 s vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 986a.doc version 1.0 10.05.2005 vi telefilter filter specification tfs 986a 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m history version reason of changes name date 1.0 - generation of development s pecification m.springfeldt 2 2 . 0 4 . 2 0 0 4 1.1 - remove group delay ripple requirement dr. wall 06.05.2004 1.2 - change remark text maximum attenuation to minimum attenuation m.springfeldt 30.07.2004 - change relative attenuation 1075?1500 mhz from 50 db to 40 db 1.3 - generation of filter specification martens 03.12.2004 1.4 - change package according to customer requirement noack 12.04.2005 automatically replaced footer by standard footer. automatically replaced header by standard header. abschnitt construction w u rde bearbeitet. vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation.


▲Up To Search▲   

 
Price & Availability of TFS986A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X