  Datasheet File OCR Text:
 45W Single Output LED Power Supply
Features :
Universal AC input / Full range
PLP-45
series
Protections: Short circuit / Overload / Over voltage Built-in active PFC function Cooling by free air convection Output current level adjustable 100% full load burn-in test High reliability Suitable for built-in applications of LED lighting 2 years warranty
SELV
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CURRENT ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER CURRENT PROTECTION SHORT CIRCUIT OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS
Note.5
EQUIVALENT (
except for 48V )
PLP-45-12 12V 3.8A 0 ~ 3.8A 45.6W 2.85 ~ 3.8A 10% 3.0% 5.0% CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V
PLP-45-24 24V 18 ~ 24V 1.9A 0 ~ 1.9A 45.6W 3.8Vp-p 1.425 ~ 1.9A
PLP-45-48 48V 36 ~ 48V 0.95A 0 ~ 0.95A 45.6W 4.8Vp-p 0.715 ~ 0.95A
RIPPLE & NOISE (max.) Note.2 4.2Vp-p
1000ms / 230VAC 2000ms / 115VAC at full load
Note.4 90 ~ 264VAC
47 ~ 63Hz PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC 86% 0.6A/115VAC 42A/230VAC 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed 15 ~ 18V -30 ~ +70 28 ~ 35V (Refer to output load derating curve) 57 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes TUV EN61347-1, EN61347-2-13 approved, design refer to UL60950-1 0.3A/230VAC 89% 89%
<0.75mA / 240VAC
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-3-2 Class C( 75% load); EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,EN61547, light industry level, criteria A 586.5Khrs min. MIL-HDBK-217F (25 ) 101.6*50.8*28mm (L*W*H) 0.16Kg; 96pcs/16.4Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor, direct connecting to LED's is not suggested for models with "RIPPLE & NOISE" > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. Heat sink HS1,HS2 can not be shorted. 7. Heat sink HS1 must have safety isolation distance with system case.
File Name:PLP-45-SPEC 2009-10-06
45W Single Output LED Power Supply
Mechanical Specification
101.6 3.175 95.25
PLP-45
series
Unit:mm
3.175
HS1 FS1 1 2 3 CN1
HS2
. 50.8
. 44.45
SVR1
CN2 1 2
4-
3.2
28
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
3max.
1.HS1,HS2 can not be shorted. 2.HS1 must have safety isolation distance with system case.
DC Output Connector (CN2) : JST B2P-VH or equivalent
Pin No. 1 2 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
Block Diagram
EMI FILTER & RECTIFIERS RECTIFIERS & FILTER DETECTION CIRCUIT PWM & PFC CONTROL O.V.P.
fosc : 90KHz(115VAC) 120KHz(230VAC)
POWER SWITCHING +V -V
I/P
FG
O.L.P.
O.C.P.
Derating Curve
Static Characteristics
Ta:25
100
100 90
80
80 70
60
LOAD (%)
40
LOAD (%)
-25 -5 0 20 40 50 60 70 (HORIZONTAL)
50
60 50 40
20
-30
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:PLP-45-SPEC 2009-10-06


▲Up To Search▲   

 
Price & Availability of PLP-45-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X