 Agilent 4-Port PNA-L Microwave Network Analyzer
N5230C 300 kHz to 13.5, 20 GHz
Data Sheet
www..com
Note: Specification information in this document is also available within the PNA-L network analyzer's internal Help system.
Table of Contents
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Corrected System Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Table 1. System dynamic range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 2. Extended dynamic range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 N5230C Option 140/145/146/240/245/246 Corrected system performance with 3.5mm connectors . . . . . . . . . . . 6 Table 3. 85052B Calibration kit N5230C Option 140/145/146/240/245/246 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Table 4. N4433A Electronic calibration module N5230C Option 140/145/146/240/245/246 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 5. Uncorrected system performance . . . . . . . . . . . . . . . . . . . . . . . 10 Table 6. Test port output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Table 7: Test port input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 8. Dynamic accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 9. Test port input (group delay) . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 10. Miscellaneous information . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 11. Front panel information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 12. Rear panel information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table 13. Analyzer environment and dimensions . . . . . . . . . . . . . . . . . 23 23 24 25
Measurement Throughput Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 14. Typical cycle time (ms) for measurement completion . . . . . . 26 Table 15. Cycle time vs IF bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 16. Cycle time vs number of points . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 17. Data transfer time (ms). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Specifications: Front-Panel Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 18: Measurement receiver inputs, 0.1 dB typical compression . Table 19: Reference receiver input at max. specified output power . . Table 20: Reference output at max. specified output power. . . . . . . . . Table 21: Source outputs at max. specified output power . . . . . . . . . . Table 22: Coupler inputs, insertion loss of coupler thru. . . . . . . . . . . . Table 23: Coupler outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 29 29 30 30 30
Test Set Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
N5230C Option 140 or 240 (standard test set and standard power range) network analyzer. . . 31 N5230C Option 145 or 245 (configurable test set and extended power range) network analyzer . . 31 N5230C Option 146 or 246 (configurable test set, extended power range, and internal second source) network analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Web Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
www..com
2
This is a subset of technical specifications for the N5230C Options 140, 145, 146, 240, 245, and 246 network analyzers. * Option 140, 300 kHz to 13.5 GHz, 4-port with standard test set and standard power range * Option 145, 300 kHz to 13.5 GHz, 4-port with configurable test set and extended power range * Option 146, 300 kHz to 13.5 GHz, 4-port with configurable test set and extended power range with internal second source * Option 240, 300 kHz to 20 GHz, 4-port with standard test set and standard power range * Option 245, 300 kHz to 20 GHz, 4-port with configurable test set and extended power range * Option 246, 300 kHz to 20 GHz, 4-port with configurable test set and extended power range with internal second source To view or print the N5230C technical specifications, visit our web site at www.agilent.com/find/pnal This N5230C document provides technical specifications for the following calibration kit and ECal module only: 85052B and N4433A. Please download our free Uncertainty Calculator from www.agilent.com/find/na_calculator to generate the curves for your calibration kit and PNA setup.
Definitions
All specifications and characteristics apply over a 25 C 5 C range (unless otherwise stated) and 90 minutes after the instrument has been turned on. Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Characteristic (char.): A performance parameter that the product is expected to meet before it leaves the factory, but that is not verified in the field and is not covered by the product warranty. A characteristic includes the same guardbands as a specification. Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty. Nominal (nom.): A general, descriptive term that does not imply a level of performance. It is not covered by the product warranty. Calibration: The process of measuring known standards to characterize a network analyzer's systematic (repeatable) errors. Corrected (residual): Indicates performance after error correction (calibration). It is determined by the quality of calibration standards and how well "known" they are, plus system repeatability, stability, and noise.
www..com
Uncorrected (raw): Indicates instrument performance without error correction. The uncorrected performance affects the stability of a calibration. Standard: When referring to the analyzer, this includes no options unless noted otherwise.
3
Corrected System Performance
The specifications in this section apply for measurements made with the N5230C Options 140, 145, 146, 240, 245, and 246 analyzers with the following conditions: * 10 Hz IF bandwidth * No averaging applied to data * Isolation calibration with an averaging factor of 8
Table 1. System dynamic range at test port1
Standard configuration and standard power range (Options 140, 240)
Description 300 kHz to 10 MHz2 10 MHz to 4 GHz2 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Specification (dB) at test port 120 118 115 107 107 103 Typical (dB) at test port 111 128 129 127 119 119 116
Configurable test set and extended power range (Options 145, 245) Configurable test set, extended power range, and internal second source (Options 146, 246)
Description 300 kHz to 10 MHz2 10 MHz to 4 GHz2 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Specification (dB) at test port 120 118 113 105 105 98 Typical (dB) at test port 111 128 128 125 117 117 115
1. The system dynamic range is calculated as the difference between the noise floor and the specified source maximum output power. The effective dynamic range must take measurement uncertainties and interfering signals into account. 2. May be degraded typically by 10 dB at particular frequencies (multiples of 5 MHz) below 500 MHz due to spurious receiver residuals. Methods are available to regain the full dynamic range.
www..com
4
Table 2. Extended dynamic range1
Configurable test set and extended power range (Options 145, 245) Configurable test set, extended power range, and internal second source (Options 146, 246)
Description 300 kHz to 10 MHz2 10 MHz to 4 GHz2 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Specification (dB) at direct receiver access input 136 134 129 121 121 114 Typical (dB) at direct receiver access input 124
1. The direct receiver access input extended dynamic range is calculated as the difference between the direct receiver access input noise floor and the source maximum output power. The effective dynamic range must take measurement uncertainties and interfering signals into account. This setup should only be used when the receiver input will never exceed its compression or damage level. When the analyzer is in segment sweep mode, it can have predefined frequency segments which will output a higher power level when the extended dynamic range is required (i.e. devices with high insertion loss), and reduced power when receiver compression or damage may occur (i.e. devices with low insertion loss). The extended range is only available in one-path transmission measurements. 2. May be degraded typically by 10 dB at particular frequencies (multiples of 5 MHz) below 500 MHz due to spurious receiver residuals. Methods are available to regain the full dynamic range.
www..com
5
N5230C Option 140/145/146/240/245/246 Corrected system performance with 3.5 mm connectors1
Note: For any Sii reflection measurement: Sjj = 0 For any Sij transmission measurement: Sji = Sij when Sij 1 Sji = 1/Sij when Sij 1 Skk = 0 for all k Table 3. 85052B Calibration kit N5230C * Option 140 or 240 standard test set and standard power range * Option 145 or 245 configurable test set and extended power range * Option 146 or 246 configurable test set and extended power range with internal second source
Applies to the N5230C Option 140/145/146/240/245/246 analyzers, 85052B (3.5mm) calibration kit, 85131F flexible test port cable set, and a full 4-port calibration. Also applies to the following condition: Environmental temperature 23 3 C, with < 1 C deviation from calibration temperature. Specification (dB) 2 to 8 to 8 GHz 13.5 GHz 44 44 33 31 44 44 0.003 0.006 (+0.02/C) (+0.03/C) 0.062 0.125 (+0.02/C) (+0.03/C)
Description Directivity Source match Load match Reflection tracking Transmission tracking
10 to 500 MHz 48 40 48 0.003 (+0.01/C) 0.017 (+0.01/C)
500 MHz to 2 GHz 48 40 48 0.003 (+0.01/C) 0.017 (+0.01/C)
13.5 to 20 GHz 44 31 44 0.006 (+0.03/C) 0.125 (+0.03/C)
Transmission uncertainty (specifications)
Magnitude
10 N5230C Option 140/145/146/240/245/246 with 85052B
10 to 500 MHz
500 MHz to 2 GHz
Uncertainty (dB)
1
2 to 8 GHz 8 to 20 GHz
0.1
S11 = S22 = 0 Source power = -5 dBm
0.01 10
www..com
1. From 300 kHz to 10 MHz, performance is characterized as "typical". To generate these typical values, please download our free Uncertainty Calculator from www.agilent.com/find/na_calculator.
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
Transmission coefficient (dB)
6
Table 3. 85052B Calibration kit (continued) N5230C * Option 140 or 240 standard test set and standard power range * Option 145 or 245 configurable test set and extended power range * Option 146 or 246 configurable test set and extended power range with internal second source
Phase
100
N5230C Option 140/145/146/240/245/246 with 85052B 10 to 500 MHz
Uncertainty (degrees)
500 MHz to 2 GHz
10
2 to 8 GHz 8 to 20 GHz
1
S11 = S22 = 0 Source power = -5 dBm
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90
Transmission coefficient (dB)
Reflection uncertainty (specifications)
Magnitude
0.05 N5230C Option 140/145/146/240/245/246 with 85052B
Uncertainty (linear)
10 to 500 MHz
0.04 0.03 0.02 0.01 0 0
500 MHz to 2 GHz
2 to 8 GHz 8 to 20 GHz
S21 = S12 = 0 Source power = -5 dBm
0.2
0.4
0.6
0.8
1
Reflection coefficient (linear)
Phase
10 N5230C Option 140/145/146/240/245/246 with 85052B
10 to 500 MHz
Uncertainty (deg)
8 6 4 2 0 0 0.2 0.4 0.6
500 MHz to 2 GHz
2 to 8 GHz 8 to 20 GHz
www..com
S21 = S12 = 0 Source power = -5 dBm
0.8
1
Reflection coefficient (linear)
7
N5230C Option 140/145/146/240/245/246 Corrected system performance with 3.5 mm connectors1 (continued)
Table 4. N4433A Electronic calibration module N5230C * Option 140 or 240 standard test set and standard power range * Option 145 or 245 configurable test set and extended power range * Option 146 or 246 configurable test set and extended power range with internal second source
Applies to the N5230C Option 140/145/146/240/245/246 analyzers, N4433A electronic calibration module, 85131F flexible test port cable set, and a full 4-port calibration. Also applies to the following condition: Environmental temperature 23 3 C, with < 1 C deviation from calibration temperature. 10 to 500 MHz to Description 500 MHz 2 GHz Directivity 52 52 Source match 42 42 Load match 45 45 Reflection 0.060 0.060 tracking (+0.01/C) (+0.01/C) Transmission 0.045 0.039 tracking (+0.01/C) (+0.01/C) Transmission uncertainty (specifications) Specification (dB) 2 to 8 to 8 GHz 13.5 GHz 47 45 39 31 41 35 0.090 0.040 (+0.02/C) (+0.03/C) 0.055 0.127 (+0.02/C) (+0.03/C) 13.5 to 20 GHz 45 31 35 0.180 (+0.03/C) 0.160 (+0.03/C)
Magnitude
10
N5230C Option 140/145/146/240/245/246 full 2-port2 cal using N4433A
10 to 500 MHz
Uncertainty (dB)
500 MHz to 2 GHz
1
2 to 8 GHz 8 to 20 GHz
0.1
S11 = S22 = 0 Source power = -5 dBm
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90
Transmission coefficient (dB)
Phase
100
N5230C Option 140/145/146/240/245/246 full 2-port2 cal using N4433A
10 to 500 MHz
Uncertainty (degrees)
500 MHz to 2 GHz
10
2 to 8 GHz 8 to 20 GHz
1
S11 = S22 = 0 Source power = -5 dBm
www..com
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90
Transmission coefficient (dB)
1. From 300 kHz to 10 MHz, performance is characterized as "typical". To generate these typical values,
8
please download our free Uncertainty Calculator from www.agilent.com/find/na_calculator. 2. All of the curves are for 2-port calibrations. Multiport uncertainties are currently not supported.
Table 4. N4433A Electronic calibration module (continued) N5230C * Option 140 or 240 standard test set and standard power range * Option 145 or 245 configurable test set and extended power range * Option 146 or 246 configurable test set and extended power range with internal second source
Reflection uncertainty (specifications)
Magnitude
0.05
N5230C Option 140/145/146/240/245/246 with N4433A 10 to 500 MHz
500 MHz to 2 GHz
2 to 8 GHz 8 to 20 GHz
0.04
Uncertainty (linear)
0.03 0.02 0.01 0 0 0.2 0.4 0.6 0.8 1
S21 = S12 = 0 Source power = -5 dBm
Reflection coefficient (linear)
Phase
10 8 N5230C Option 140/145/146/240/245/246 with N4433A
10 to 500 MHz
500 MHz to 2 GHz
2 to 8 GHz 8 to 20 GHz
Uncertainty (deg)
6 4 2 0 0 0.2 0.4 0.6 0.8 1
S21 = S12 = 0 Source power = -5 dBm
Reflection coefficient (linear)
www..com
9
Table 5. Uncorrected system performance1
Directivity
Specifications Options 140, 145, 146, 240, 245, 246
Typicals Options 140, 145, 146, 240, 245, 246 -23 dB
300 kHz to 10 MHz 10 MHz to 1 GHz 1 to 3 GHz 3 to 5 GHz 5 to 11.5 GHz 11.5 to 13.5 GHz 13.5 to 20 GHz Source match 300 kHz to 10 MHz 10 MHz to 1 GHz 1 to 3 GHz 3 to 5 GHz 5 to 10.5 GHz 10.5 to 11.5 GHz 11.5 to 13.5 GHz 13.5 to 20 GHz Load match 300 kHz to 10 MHz 10 MHz to 1 GHz 1 to 3 GHz 3 to 5 GHz 5 to 11.5 GHz 11.5 to 13.5 GHz 13.5 to 16 GHz 16 to 20 GHz Crosstalk2 300 kHz to 5 MHz 5 to 10 MHz 10 to 45 MHz 45 MHz to 4 GHz 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz
-28 dB -25 dB -20 dB -17 dB -15 dB -15 dB -8 dB -12 dB -12 dB -12 dB -12 dB -10 dB -8 dB -8 dB -9 dB -20 dB -20 dB -18 dB -12 dB -7 dB -7 dB -7.5 dB - - - - - - - - - -70 dB -100 dB -110 dB -122 dB -123 dB -120 dB -115 dB -115 dB -110 dB
1. Specifications apply over environmental temperature of 25 C 5 C with less than 1 C variation from calibration temperature. 2. Measurement conditions: normalized to a thru, measured with two shorts, 10 Hz IF bandwidth, averaging factor of 8, alternate mode source power set to the lesser of the maximum power out or the maximum receiver power.
www..com
10
Table 6. Test port output1
Description
Specifications Options Options Options Options 140, 240 145, 146, 245, 246 140, 240
Typicals 145, 146, 245, 246
Frequency range Options 140, 145, 146 300 kHz to 13.5 GHz Options 240, 245, 246 300 kHz to 20 GHz Nominal power -5 dBm -8 dBm Frequency resolution 1 Hz CW accuracy 1 ppm Frequency stability - - - -
Preset power; attenuator switch point 10 dB below nominal power
0.05 ppm. -10 to 70 C 0.1 ppm/yr maximum Typicals Options 140, 240 Options 145, 146, 245, 246
Description
Specifications Options Options 140, 240 145, 146, 245, 246
www..com
Power level accuracy Variation from nominal power in range 0 300 kHz to 10 MHz 1.0 dB 1.0 dB 10 MHz to 2 GHz 1.0 dB 1.0 dB 2 to 10.5 GHz 1.5 dB 1.5 dB 10.5 to 13.5 GHz 2.5 dB 2.5 dB 13.5 to 20 GHz 2.5 dB 2.5 dB Max leveled power 300 kHz to 10 MHz +8 dBm +8 dBm 10 MHz to 4 GHz +8 dBm +8 dBm +12 dBm +11 dBm 4 to 6 GHz +6 dBm +6 dBm +10 dBm +9 dBm 6 to 10.5 GHz +3 dBm +1 dBm +8 dBm +6 dBm 10.5 to 13.5 GHz 0 dBm -2 dBm +5 dBm +3 dBm 13.5 to 15 GHz 0 dBm -2 dBm +5 dBm +3 dBm 15 to 20 GHz -3 dBm -8 dBm +2 dBm -1 dBm Power level linearity Specified on Port 1 only. Ports 2, 3, 4 performance is Typical. Test is at the nominal power level. 300 kHz to 10 MHz 2.0 dB 2.0 dB 10 MHz to 1 GHz 2.0 dB 2.0 dB 1 to 13.5 GHz 1.5 dB 1.5 dB 13.5 to 20 GHz 1.5 dB 1.5 dB Power sweep range (ALC) ALC range starts at maximum-leveled power and decreases by the dB amount specified here. 300 kHz to 10 MHz 35 dB 35 dB 10 MHz to 4 GHz 33 dB 33 dB 4 to 6 GHz 31 dB 31 dB 6 to 10.5 GHz 28 dB 26 dB 10.5 to 13.5 GHz 25 dB 23 dB 13.5 to 15 GHz 25 dB 23 dB 15 to 20 GHz 22 dB 17 dB Power resolution 0.01 dB 0.01 dB
11
Table 6. Test port output1 (Continued)
Description
Typicals Options Options 140, 240 145, 146, 245, 246
Power range 300 kHz to 10 MHz -27 to +8 dBm -87 to +8 dBm 10 to 45 MHz -27 to +12 dBm -87 to +11 dBm 45 MHz to 4 GHz -27 to +12 dBm -87 to +11 dBm 4 to 6 GHz -27 to +10 dBm -87 to +9 dBm 6 to 10.5 GHz -27 to +8 dBm -87 to +6 dBm 10.5 to 13.5 GHz -27 to +5 dBm -87 to +3 dBm 13.5 to 15 GHz -27 to +5 dBm -87 to +3 dBm 15 to 20 GHz -27 to +2 dBm -87 to -1 dBm Power settings Minimum power setting -30 dBm -90 dBm Maximum power setting +20 dBm +20 dBm Harmonics (2nd or 3rd) at maximum output power 2 In-band source harmonics 300 kHz to 10 MHz -17 dBc 10 MHz to 1 GHz -17 dBc 1 to 13.5 GHz -20 dBc 13.5 to 20 GHz -20 dBc Non-harmonic spurious (at nominal output power 2) 300 kHz to 20 GHz -50 dBc for offset frequency > 1 kHz Typical performance Phase noise (Nominal power at test port) 10 kHz Offset 300 kHz to 10 MHz -86 dBc/Hz 10 MHz to 1.5 GHz -86 dBc/Hz 1.5 to 3.125 GHz -83 dBc/Hz 3.125 to 6.25 GHz -77 dBc/Hz 6.25 to 12.5 GHz -71 dBc/Hz 12.5 to 13.5 GHz -65 dBc/Hz 13.5 to 20 GHz -65 dBc/Hz 100 kHz Offset -86 dBc/Hz -91 dBc/Hz -91 dBc/Hz -85 dBc/Hz -79 dBc/Hz -73 dBc/Hz -73 dBc/Hz 1 MHz Offset -95 dBc/Hz -95 dBc/Hz -95 dBc/Hz -89 dBc/Hz -83 dBc/Hz -77 dBc/Hz -77 dBc/Hz
1. For Options 140/145/240/245, performance specified on Port 1 only; Ports 2, 3, and 4 performance is typical. For Options 146/246, performance is specified on Ports 1 and 3 only; Ports 2 and 4 performance is typical. 2. Spurious signal levels are valid for a 10 MHz span centered on the carrier frequency. Spurious signals up to -15 dBc may exist outside the span. These signals do not affect the accuracy of the network analyzer measurements.
www..com
12
Table 7: Test port input
Description
Specification Options 140, 145, 146, 240, 245, 246
Typicals Options 140, 145, 146, 240, 245, 246
Test port noise floor Total average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. 10 Hz IF bandwidth 300 kHz to 10 MHz < -103 dBm 10 to 500 MHz < -112 dBm < -116 dBm 500 MHz to 4 GHz < -112 dBm < -120 dBm 4 to 10.5 GHz < -112 dBm < -119 dBm 10.5 to 13.5 GHz < -107 dBm < -114 dBm 13.5 to 15 GHz < -107 dBm < -114 dBm 15 to 20 GHz < -106 dBm < -114 dBm 1 KHz IF bandwidth 300 kHz to 10 MHz < -83 dBm 10 to 500 MHz < -92 dBm < -96 dBm 500 MHz to 4 GHz < -92 dBm < -100 dBm 4 to 10.5 GHz < -92 dBm < -99 dBm 10.5 to 13.5 GHz < -87 dBm < -94 dBm 13.5 to 15 GHz < -87 dBm < -94 dBm 15 to 20 GHz < -86 dBm < -94 dBm Direct receiver access input noise floor (Options 145, 146, 245, 246) Total average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. 10 Hz IF bandwidth 300 kHz to 10 MHz < -119 dBm 10 to 500 MHz < -128 dBm < -132 dBm 500 MHz to 4 GHz < -128 dBm < -136 dBm 4 to 10.5 GHz < -128 dBm < -135 dBm 10.5 to 13.5 GHz < -123 dBm < -130 dBm 13.5 to 15 GHz < -123 dBm < -130 dBm 15 to 20 GHz < -122 dBm < -130 dBm 1 KHz IF bandwidth 300 kHz to 10 MHz < -99 dBm 10 to 500 MHz < -108 dBm < -112 dBm 500 MHz to 4 GHz < -108 dBm < -116 dBm 4 to 10.5 GHz < -108 dBm < -115 dBm 10.5 to 13.5 GHz < -103 dBm < -110 dBm 13.5 to 15 GHz < -103 dBm < -110 dBm 15 to 20 GHz < -102 dBm < -110 dBm Specification Options 140, 145, 146, 240, 245, 246 Compression level (at +8 dBm except as noted) Power Compression 300 kHz to 10 MHz 10 to 50 MHz +8 dBm 0.35 dB 50 MHz to 1 GHz +8 dBm 0.35 dB 1 to 8 GHz +8 dBm 0.25 dB 8 to 12.5 GHz +8 dBm 0.30 dB 12.5 to 13.5 GHz +8 dBm 0.55 dB 13.5 to 20 GHz +8 dBm 0.55 dB Test port compression at 0.1 dB 300 kHz to 10 MHz - - 10 MHz to 1 GHz - - 1 to 12.5 GHz - - 12.5 to 13.5 GHz - - 13.5 to 20 GHz - - Description Typicals Options 140, 145, 146, 240, 245, 246 Power +5 dBm Compression 0.10 dB
www..com
+5 dBm +9 dBm +10 dBm +9 dBm +9 dBm
13
Table 7. Test port input (Continued)
Description
Specifications Options 140, 240 Options 145, 245 Options 146, 246
Typicals Options 140, 240 Options 145, 245 Options 146, 246
Trace noise magnitude Ratioed measurement, nominal power at test port. 100 kHz IF bandwidth 300 kHz to 10 MHz 10 MHz to 10.5 GHz 0.006 dB rms 0.008 dB rms 10.5 to 13.5 GHz 0.010 dB rms 0.014 dB rms 13.5 to 20 GHz 0.010 dB rms 0.014 dB rms 600 kHz IF bandwidth 300 kHz to 10 MHz - 10 MHz to 10.5 GHz - 10.5 to 13.5 GHz - 13.5 to 20 GHz - 100 kHz IF bandwidth Measured at maximum specified power 300 kHz to 10 MHz - 10 MHz to 2 GHz - 2 to 10.5 GHz - 10.5 to 13.5 GHz - 13.5 to 20 GHz -
0.016 dB rms 0.038 dB rms 0.038 dB rms
0.015 dB rms 0.004 dB rms 0.007 dB rms 0.007 dB rms 0.015 dB rms 0.013 dB rms 0.017 dB rms 0.017 dB rms
0.030 dB rms 0.005 dB rms 0.009 dB rms 0.009 dB rms 0.030 dB rms 0.015 dB rms 0.023 dB rms 0.023 dB rms
0.050 dB rms 0.013 dB rms 0.026 dB rms 0.026 dB rms 0.050 dB rms 0.032 dB rms 0.063 dB rms 0.063 dB rms
0.005 dB rms 0.001 dB rms 0.002 dB rms 0.006 dB rms 0.006 dB rms
0.010 dB rms 0.003 dB rms 0.003 dB rms 0.009 dB rms 0.009 dB rms
0.012 dB rms 0.004 dB rms 0.004 dB rms 0.023 dB rms 0.023 dB rms
Trace noise phase Ratioed measurement, nominal power at test port. 100 kHz IF bandwidth 300 kHz to 10 MHz 10 MHz to 10.5 GHz 0.05 rms 0.07 rms 10.5 to 13.5 GHz 0.08 rms 0.10 rms 13.5 to 20 GHz 0.08 rms 0.10 rms 600 kHz IF bandwidth 300 kHz to 10 MHz - 10 MHz to 10.5 GHz - 10.5 to 13.5 GHz - 13.5 to 20 GHz - 100 kHz IF bandwidth Measured at maximum specified power 300 kHz to 10 MHz - 10 MHz to 2 GHz - 2 to 10.5 GHz - 10.5 to 13.5 GHz - 13.5 to 20 GHz - Stability magnitude Stability as defined as a ratio measurement made at the test port. 300 kHz to 10 MHz - 10 MHz to 2 GHz - 2 to 4 GHz - 4 to 13.5 GHz - 13.5 to 16 GHz - 16 to 19 GHz - www..com 19 to 20 GHz -
0.130 rms 0.250 rms 0.250 rms
0.110 rms 0.025 rms 0.050 rms 0.050 rms 0.110 rms 0.080 rms 0.120 rms 0.120 rms
0.180 rms 0.035 rms 0.060 rms 0.060 rms 0.180 rms 0.100 rms 0.160 rms 0.160 rms
0.280 rms 0.090 rms 0.170 rms 0.170 rms 0.300 rms 0.200 rms 0.430 rms 0.430 rms
0.040 rms 0.007 rms 0.012 rms 0.040 rms 0.040 rms
0.050 rms 0.012 rms 0.015 rms 0.060 rms 0.060 rms
0.075 rms 0.013 rms 0.030 rms 0.150 rms 0.150 rms
0.015 dB/C 0.010 dB/C 0.015 dB/C 0.020 dB/C 0.020 dB/C 0.025 dB/C 0.030 dB/C
0.015 dB/C 0.010 dB/C 0.015 dB/C 0.020 dB/C 0.020 dB/C 0.025 dB/C 0.030 dB/C
14
Table 7. Test port input (Continued)
Description
Specifications Options 140, 240 Options 145, 245 Options 146, 246
Typicals Options 140, 240 Options 145, 245 Options 146, 246
Stability phase Stability as defined as a ratio measurement made at the test port. 300 kHz to 10 MHz - 10 to 45 MHz - 45 to 500 MHz - 500 MHz to 2 GHz - 2 to 4 GHz - 4 to 8 GHz - 8 to 13.5 GHz - 13.5 to 16 GHz - 16 to 20 GHz - Reference level magnitude Range Resolution Reference level phase Range Resolution Damage input level Test port 1, 2, 3, and 4 Receivers R, A, B, C, D Source out (reference) Source out (test ports) Coupler thru Coupler arm
0.360/C 0.020/C 0.030/C 0.050/C 0.100/C 0.150/C 0.300/C 0.300/C 0.350/C
0.360/C 0.020/C 0.030/C 0.070/C 0.150/C 0.250/C 0.500/C 0.500/C 0.650/C
200 dB .001 dB
200 dB .001 dB
200 dB .001 dB
500 .01
500 .01 - - - - - - -
500 .01 +27 dBm or 16 VDC +27 dBm or 16 VDC +15 dBm or 16 VDC +27 dBm or 16 VDC +27 dBm or 16 VDC +27 dBm or 16 VDC +15 dBm or 0 VDC
www..com
15
Table 8. Dynamic Accuracy (specification)
Accuracy of the test port input power reading relative to the reference input power level. Dynamic accuracy is verified with the following measurements: * Compression over frequency * IF linearity at a single frequency of 1.195 GHz using a reference level of -20 dBm for an input power range of 0 to -110 dBm Dynamic Accuracy 0.045 GHz
Magnitude
10
N5230C Option 140/145/146/240/245/246 -10 dBm at 0.045 GHz
-20 dBm at 0.045 GHz
Accuracy (dB)
1
-30 dBm at 0.045 GHz -40 dBm at 0.045 GHz
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 140/145/146/240/245/246 -10 dBm at 0.045 GHz
Accuracy (degrees)
-20 dBm at 0.045 GHz
10
-30 dBm at 0.045 GHz -40 dBm at 0.045 GHz
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
16
Table 8. Dynamic Accuracy (continued)
Dynamic Accuracy 0.500 GHz
Magnitude
10
N5230C Option 140/145/146/240/245/246
-10 dBm at 0.500 GHz
-20 dBm at 0.500 GHz
Accuracy (dB)
-30 dBm at 0.500 GHz
1
-40 dBm at 0.500 GHz
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 140/145/146/240/245/246
-10 dBm at 0.500 GHz
-20 dBm at 0.500 GHz
Accuracy (degrees)
10
-30 dBm at 0.500 GHz -40 dBm at 0.500 GHz
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
17
Table 8. Dynamic Accuracy (continued)
Dynamic Accuracy 1 to 2 GHz
Magnitude
10
N5230C Option 140/145/146/240/245/246
-10 dBm (1 to 2 GHz)
-20 dBm (1 to 2 GHz)
Accuracy (dB)
1
-30 dBm (1 to 2 GHz) -40 dBm (1 to 2 GHz)
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 140/145/146/240/245/246
-10 dBm (1 to 2 GHz)
Accuracy (degrees)
-20 dBm (1 to 2 GHz)
10
-30 dBm (1 to 2 GHz) -40 dBm (1 to 2 GHz)
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
18
Table 8. Dynamic Accuracy (continued)
Dynamic Accuracy 2 to 12.5 GHz
Magnitude
10
N5230C Option 140/145/146/240/245/246
-10 dBm (2 to 12.5 GHz)
-20 dBm (2 to 12.5 GHz)
Accuracy (dB)
1
-30 dBm (2 to 12.5 GHz) -40 dBm (2 to 12.5 GHz)
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 140/145/146/240/245/246
-10 dBm (2 to 12.5 GHz)
Accuracy (degrees)
-20 dBm (2 to 12.5 GHz)
10
-30 dBm (2 to 12.5 GHz) -40 dBm (2 to 12.5 GHz)
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
19
Table 8. Dynamic Accuracy (continued)
Dynamic Accuracy 12.5 to 13.5 GHz
Magnitude
10
N5230C Option 140/145/146/240/245/246
-10 dBm (12.5 to 13.5 GHz)
-20 dBm (12.5 to 13.5 GHz)
Accuracy (dB)
1
-30 dBm (12.5 to 13.5 GHz) -40 dBm (12.5 to 13.5 GHz)
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 140/145/146/240/245/246
-10 dBm (12.5 to 13.5 GHz)
Accuracy (degrees)
-20 dBm (12.5 to 13.5 GHz)
10
-30 dBm (12.5 to 13.5 GHz) -40 dBm (12.5 to 13.5 GHz)
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
20
Table 8. Dynamic Accuracy (continued)
Dynamic Accuracy 13.5 to 20 GHz
Magnitude
10
N5230C Option 240/245/246
-10 dBm (13.5 to 20 GHz)
-20 dBm (13.5 to 20 GHz)
Accuracy (dB)
1
-30 dBm (13.5 to 20 GHz) -40 dBm (13.5 to 20 GHz)
0.1
0.01 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
Phase
100
N5230C Option 240/245/246
-10 dBm (13.5 to 20 GHz)
Accuracy (degrees)
-20 dBm (13.5 to 20 GHz)
10
-30 dBm (13.5 to 20 GHz) -40 dBm (13.5 to 20 GHz)
1
0.1 10 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120
Test port power (dBm)
www..com
21
Table 9. Test port input (group delay)
Description Aperture (selectable) Maximum aperture Range Maximum delay Accuracy
Supplemental information (typ.) (frequency span)/(number of points -1) 20% of frequency span 0.5 x (1/minimum aperture) Limited to measuring no more than 180 of phase change within the minimum aperture See graph below. (Char.)
The following graph shows characteristic group delay accuracy with full 2-port calibration and a 10 Hz IF bandwidth. Insertion loss is assumed to be < 2 dB and electrical length to be ten meters. For any Sij group delay measurement, Sii = 0, Sij = 0, Skl = 0 for all kl ij
Group delay (typical)
100 10 N5230C Option 140/145/146/240/245/246 with 85052B
Accuracy (nsec)
1 0.1 0.01
Frequency = 1 GHz S11 = 0; S21 = 1; S12 = 0; S22 = 0 IF bandwidth = 10 Hz; Average factor = 1 Cal power = -5 dBm; Meas power = -5 dBm; Electrical length = 10 m
0.001 0.01 0.1 1 10 100
Aperture (MHz)
In general, the following formula can be used to determine the accuracy, in seconds, of specific group delay measurement: Phase Accuracy (deg)/[360 Aperture (Hz)] Depending on the aperture and device length, the phase accuracy used is either incremental phase accuracy or worst case phase accuracy.
www..com
22
General Information
Table 10. Miscellaneous information
Description System IF bandwidth range CPU
Supplemental information 1 Hz to 600 kHz, nominal Intel(R) 1.1 GHz Pentium(R) M with 1 GByte RAM
Table 11. Front panel information
Description RF connectors Type Center pin recession Display Size
Supplemental information Options 140, 145, 146, 240, 245, 246: 3.5 mm (male), 50 ohm (nominal) 0.002 in. (characteristic) 21.3 cm (8.4 in) diagonal color active matrix LCD; 1024 (horizontal) X 768 (vertical) resolution A display is considered faulty if: * A complete row or column of "stuck" or "dark" pixels. * More than six "stuck on" pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications. * More than twelve "dark" pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications. * Two or more consecutive "stuck on" pixels or three or more consecutive "dark" pixel (but no more than one set of two consecutive dark pixels) "Stuck on" of "dark" pixels less than 6.5 mm apart (excluding consecutive pixels) 60 Hz 500 dB (at 20 dB/div), max 500, max 10 pUnits, min 1000 Units, max 0.001 dB/div, min 0.01/div, min 0.001 dB, min 0.01, min 0.01 mUnit, min; 0.01,min
Refresh rate Display range Magnitude Phase Polar Display resolution Magnitude Phase Marker resolution Magnitude Phase Polar
www..com
23
Table 12. Rear panel information
Description Trigger inputs/outputs 10 MHz Reference in Connector Input frequency Input level Input impedance 10 MHz Reference out Connector Output frequency Signal type Output level Output impedance Harmonics VGA Video output Connector Test set IO Aux IO
Supplemental information BNC (f), TTL/CMOS compatible BNC, female 10 MHz 10 ppm, typical -15 to +20 dBm, typical 200 , nom. BNC, female 10 MHz 1 ppm, typical Sine Wave, typical +10 dBm 4 dB into 50 , typical 50 , nominal < -40 dBc, typical 15-pin mini D-Sub; Drives VGA compatible monitors 25-pin D-Sub connector, female, available for external test set control 25-pin D-Sub connector, male, analog and digital I/O
Handler IO 36-pin parallel I/O port; all input/output signals are default set to negative logic; can be reset to positive logic via GPIB command GPIB Two ports: dedicated controller and dedicated talker/listener 24-pin D-sub (Type D-24), female; compatible with IEEE-488. USB Port 1 port on front panel and 4 ports on rear panel. LAN 10/100BaseT Ethernet, 8-pin configuration; auto selects between the two data rates Line power (single phase) Frequency, voltage Maximum 50/60 Hz/400 Hz for 100-120 V, 50/60 Hz for 220-240 V, power supply is auto switching 350 Watts
Note: Option H08 and Option H11 specifications are not provided in this N5230C specifications document.
www..com
24
Table 13. Analyzer environment and dimensions
Description General environmental EMC
Supplemental information Complies with European EMC directive 2004/108/EC * IEC/EN 61326-1:2005 * CISPR Pub 11 Group 1, class A * AS/NZS CISPR11:2004 * ICES/NMB-001 Complies with European Low Voltage Directive 2006/95/EC * IEC/EN 61010-1:2001 * Canada: CSA C22.2 No. 61010-1:2004 * USA: UL 61010-1:2004 0 to +40 C Instrument powers up and displays no error messages within this temperature range (except for "source unleveled" error message that may occur at temperatures outside the specified performance temperature range of 25 5 C). 23 C 3 C with less than 1 C deviation from calibration temp. Type tested 0 to 95% at 40 C, non-condensing 0 to 4600 m (15,000 ft.) -40 to +70 C Height 267 mm 10.5 in 280 mm 11 in 280 mm 11 in 280 mm 11 in 280 mm 11 in Width 426 mm 16.75 in 435 mm 17.10 in 458 mm 18 in 483 mm 19 in 483 mm 19 in Depth 427 mm 16.8 in 470 mm 18.5 in 501 mm 19.7 in 470 mm 18.5 in 501 mm 19.7 in
Safety
Operating environment Temperature
Error-corrected temperature range Relative humidity Altitude Non-operating storage environment Temperature Cabinet dimensions
Excluding front and rear panel hardware and feet As shipped - includes front panel connectors, rear panel bumpers, and feet. As shipped plus handles As shipped plus rack-mount flanges As shipped plus handles and rack-mount flanges Weight Net N5230C Shipping N5230C
24.9 kg (55 lb), nominal 36.3 kg (80 lb), nominal
www..com
25
Measurement Throughput Summary
Table 14. Typical cycle time1 (ms) for measurement completion
Number of Points 201 401 801 1601 Start 8 GHz, stop 18 GHz, 600 kHz IF bandwidth Uncorrected 21.148 21.743 23.01 25.198 4-Port cal 74.597 82.296 296.5 307.75 Start 300 kHz, stop 10 GHz, 600 kHz IF bandwidth Uncorrected 19.814 22.801 24.973 29.01 4-Port cal 69.752 85.111 100.125 129.347 Start 300 kHz, stop 20 GHz, 600 kHz IF bandwidth Uncorrected 32.575 34.7 39.237 43.155 4-Port cal 121.254 133.626 157.506 179.223 Start 8 GHz, stop 18 GHz, 100 kHz IF bandwidth Uncorrected 38.083 51.816 55.488 56.36 4-Port cal 143.271 201.814 215.056 230.133 Start 300 kHz, stop 10 GHz, 100 kHz IF bandwidth Uncorrected 37.03 42.532 45.122 46.729 4-Port cal 137.431 162.37 194.13 192.182 Start 300 kHz, stop 20 GHz, 100 kHz IF bandwidth Uncorrected 44.98 69.408 87.161 92.475 4-Port cal 169.041 268.877 343.898 369.526 Start 8 GHz, stop 18 GHz, 50 kHz IF bandwidth Uncorrected 42.171 70.09 88.702 90.981 4-Port cal 157.107 271.791 351.517 368.02 Start 300 kHz, stop 10 GHz, 50 kHz IF bandwidth Uncorrected 43.713 61.41 66.878 69.373 4-Port cal 163.58 238.267 259.687 279.816 Start 300 kHz, stop 20 GHz, 50 kHz IF bandwidth Uncorrected 48.673 80.798 124.605 147.303 4-Port cal 184.429 313.392 493.142 587.548
16,001 54.836 538.646 67.733 480.711 69.625 487.779 184.154 934.161 198.683 906.768 198.792 914.963 371.611 1532.609 385.04 1580.761 388.46 1587.839
1. Includes sweep time, retrace time and band-crossing time. Analyzer display turned off with DISPLAY:ENABLE OFF. Add 21 ms for display on. Data for one trace (S11) measurement.
www..com
26
Table 15. Cycle Time vs IF Bandwidth
Applies to the preset condition (201 points, correction off) except for the following changes: * CF = 10 GHz * Span = 100 MHz * Display off (add 21 ms for display on) Description IF Bandwidth (Hz) 600,000 360,000 280,000 200,000 150,000 100,000 70,000 50,000 30,000 20,000 15,000 10,000 7000 5000 3000 2000 1500 1000 700 500 300 200 100 30 10 1 Typical performance Trace noise (dB rms) Cycle time (ms)1 3.13 0.00544 3.21 0.00602 3.17 0.00321 3.17 0.00259 3.19 0.00207 4.05 0.00155 4.99 0.00144 6.41 0.00121 8.78 0.00094 12.07 0.00080 14.91 0.00069 26.02 0.00052 34.54 0.00047 45.87 0.00044 69.91 0.00032 99.69 0.00029 128.18 0.00010 215.62 0.00009 291.58 0.00006 397.36 0.00007 633.86 0.00000 930.15 0.00000 1824.19 0.00000 6001.70 0.00000 17899.79 0.00000 178391.58 0.00000
1. Cycle time includes sweep and retrace time.
www..com
27
Table 16. Cycle time vs number of points
Applies to the preset condition (correction off) except for the following changes: * CF = 10 GHz * Span = 100 MHz * Display off (add 21 ms for display on) IF Bandwidth (Hz) 30,000 Number of points 3 11 51 101 201 401 801 1,601 6,401 16,001 3 11 51 101 201 401 801 1,601 6,401 16,001 3 11 51 101 201 401 801 1,601 6,401 16,001 Cycle time (ms)1 2.88 3.50 3.91 5.29 8.75 15.66 29.46 57.73 221.04 549.71 2.87 2.82 2.86 2.96 4.02 6.23 10.65 19.49 70.96 173.78 2.84 2.84 2.87 3.03 3.14 3.51 4.22 6.22 19.35 45.12
100,000
600,000
1. Cycle time includes sweep and retrace time.
Table 17. Data transfer time (ms)
www..com
Number of points 201 401 1601 SCPI over GPIB (program executed on external PC) 32-bit floating point 6 10 33 64-bit floating point 10 18 65 ASCII 53 105 406 CPI over SIU/LAN or TCP/IP socket (program executed in the analyzer) 32-bit floating point 1 2 2.5 64-bit floating point 2 2 3 ASCII 11 20 73 COM (program executed in the analyzer) 32-bit floating point < 0.2 0.2 0.3 Variant type 0.6 1 3.2 DCOM over LAN (program executed on external PC) 32-bit floating point < 0.8 1 1.6 Variant type 1.9 3 8.9
16,001 313 622 4032 7 10 720 0.9 32 7.5 82
Note: Specifications for recall and sweep speed are not provided for the N5230C analyzers.
28
Specifications: Front-Panel Jumpers
Table 18: Measurement receiver inputs (rcvr A In, rcvr B In, rcvr C In, rcvr D In) 0.1 dB Typical compression
Description Maximum input level 300 kHz to 10 MHz 10 MHz to 1 GHz 1 to 12.5 GHz 12.5 to 13.5 GHz 13.5 to 20 GHz Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 -11 dBm -7 dBm -6 dBm -7 dBm -7 dBm +15 dBm 16 V
Table 19: Reference receiver input (rcvr in) at maximum specified output power
Description Maximum input level 300 kHz to 10 MHz 10 to 45 MHz 45 to 500 MHz 500 MHz to 4 GHz 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 -15 dBm -15 dBm -15 dBm -15 dBm -16 dBm -20 dBm -21 dBm -21 dBm -27 dBm
+15 dBm 16 V
Table 20: Reference output (source out) at maximum specified output power
www..com
Description Maximum output level 300 kHz to 10 MHz 10 to 45 MHz 45 to 500 MHz 500 MHz to 4 GHz 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 -15 dBm -15 dBm -15 dBm -15 dBm -15 dBm -20 dBm -21 dBm -21 dBm -27 dBm +27 dBm 16 V
29
Table 21: Source outputs (port 1 source out, port 2 source out, port 3 source out, port 4 source out) at maximum specified output power
Description Maximum output level 300 kHz to 10 MHz 10 to 45 MHz 45 to 500 MHz 500 MHz to 4 GHz 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 +10 dBm +10 dBm +10 dBm +10 dBm +9 dBm +4 dBm +1 dBm +1 dBm -4 dBm +27 dBm 16 V
Table 22: Coupler inputs (port 1 cplr thru, port 2 cplr thru, port 3 cplr thru, port 4 cplr thru) Insertion loss of coupler thru
Description Insertion loss to test port 300 kHz to 10 MHz 10 to 45 MHz 45 to 500 MHz 500 MHz to 4 GHz 4 to 6 GHz 6 to 10.5 GHz 10.5 to 13.5 GHz 13.5 to 15 GHz 15 to 20 GHz Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 1.5 dB 1.5 dB 1.5 dB 2.0 dB 2.5 dB 2.5 dB 3.0 dB 3.0 dB 3.0 dB +27 dBm 16 V
Table 23: Coupler outputs (port 1 cplr arm, port 2 cplr arm, port 3 cplr arm, port 4 cplr arm)
Description Damage level N5230C Maximum DC level N5230C
Typical Options 145, 146, 245, 246 +15 dBm 0V
www..com
30
Test Set Block Diagrams
N5230C Option 140 or 240 standard test set and standard power range
Switch Source PORT 4 D
PORT 3 C
B Reference receiver
R A
PORT 2
PORT 1
N5230C Option 145 or 245 configurable test set, extended power range
Switch Source 60 dB
Source out Coupler thru PORT 4 D Coupler arm Receiver D in Source out Coupler thru PORT 3 C B Coupler arm Receiver C in Receiver B in Coupler arm PORT 2 Coupler thru Source out A Receiver A in Coupler arm PORT 1 Coupler thru Source out Source out Receiver R in
Reference receiver
R
N5230C Option 146 or 246 configurable test set, extended power range, and internal second source
Source 1
Source 2
60 dB
R
60 dB
A
B
C
D
www..com
Test port 1
Test port 2
Test port 3
Test port 4
31
Agilent Email Updates
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.
Remove all doubt
www.agilent.com
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilenttrained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at:
Agilent Direct
www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence.
www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand
(877) 894-4414 305 269 7500 (800) 829-4444 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008
Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700*
*0.125 /minute
Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus
Revised: July 2, 2009
Product specifications and descriptions in this document subject to change without notice.
www..com Intel Corporation.
Intel(R) and Pentium(R) are US registered trademarks of
(c) Agilent Technologies, Inc. 2008, 2009 Printed in USA, September 1, 2009 5989-7608EN