 H28
Verson 1.5
16-Bit Analog-to-Digital Converter
Standby Current Consumption 0.1 A Low Supply Current Low Power Consumption Resolution 16 Bits ENOB 14 Bits Serial Data Output (I2C bus) DESCRIPTION
The H28 is a 16 bit Analog-to-Digital Converter (ADC), which employs a delta-sigma conversion technique. With the linear input signal range of 324
mVPP ,its resolution is 14 bits.
The H28 is designed especially to meet the requirement for low power consumption, thus making it an ideal choice for battery powered systems. The H28 is equipped with a standby function, i.e. the ADC is in power down between each conversion. By utilizing this and overall low power consumption, current consumption values of 1.2 A or less can be achieved (one conversion in a second; fast mode conversion time 16 ms).
The H28 has an on-chip second order decimator filter to process the output of the second order modulator. The ADC also has two selectable conversion ranges with two optional offset levels. A bi-directional 2-wire I2C bus is used for configuring conversion parameters, starting conversion and reading out the A/D conversion result. H28 has one input channel suitable for piezo-resistive pressure sensor. In addition to pressure measurement configuration the device can be configured to temperature measurement.
FEATURES
Low Standby Current Consumption 0.1 A Low Supply Current: 0.2 A.....1.6 A Supply Voltage: 2.0 V...5.0 V Ratiometric Conversion Two Input Signal Ranges (VDD=2.35V): 405 mVPP , 105 mVPP Two Optional Offsets (VDD=2.35V): 25 mV, 33 mV Over Sampling Ratio: 512, 256, 128, 64 Conversion Times 32.2 ms...2.5 ms In Fast Mode: Over Sampling Ratio 64, Conversion Time=2.5 ms, Resolution=10 Bits Good Noise Performance due to (~) Architecture 2-Wire I2C Interface
APPLICATIONS
Battery Powered Systems Low Frequency Measurement Applications Pressure and Temperature Measurement Current/Power Consumption Critical Systems Industrial and Process Control Applications in Noisy Environments
BLOCK DIAGRAM
Figure 1. H28 block diagram
ABSOLUTE MAXIMUM RATINGS
All Voltages with Respect to Ground
Parameter Supply Voltage Voltage Range for All Pins ESD Rating
Symbol VC C VE S D
Conditions
Min 0.3 - 0.3 -2
-
Max 6.0 VI N + 0.3 2
Unit V V kV
Latchup Current Limit
IL U T
For all pins, Human Body Model (HBM), ESD Association Standard Test Method ESD-STM5.1 1998, CE S D = 100 pF, Rs = 1500 :), For all pins, test according to Micro Analog Systems specification ESQ0141. Note 1
- 100
+ 100
mA
Junction Temperature Storage Temperature
TJ m a x TS
- 55
+ 135 +125
C C
Stresses beyond those listed may cause permanent damage to the device. The device may not operate under these conditions, but it will not be destroyed. Note 1. In latchup testing the supply voltages are connected due to test current pulses and the abnormally high current normally to the tested device. Then pulsed test current is feeded consumption continues after test current pulses are cut off then to each input separately and device current consumption is the device has gone to latch up. Current pulse is turned on for 10 observed. If the device current consumption increases suddenly ms and off for 20 ms.
ELECTRICAL CHARACTERISTICS
TA = -20 C to +60 C, Typ TA = 25 C, VDD = 2.35 V, Rsensor = 4.5k: unless otherwise noted
o o o
Parameter Supply Voltage Operating Temperature Average ADC Current during Conversion Time (see Conversion Time at bottom) Average ADC Current in Pressure and Temperature Measurement during Conversion Period (no sensor current included)
Symbol VDD TA ICONV
Conditions
Min 2.0 -20
Typ 2.35 +25 30
Max 5.0 +60 50
Unit V C A
VDD = 3.6 V
IADC
Average Supply Current in Pressure Measurement during Conversion Period (including sensor bridge current)
ISAVG
P
Average Supply Current in Temperature Measurement (including sensor bridge current)
ISAVG
T
Peak Supply Current During Pressure Measurement Peak Supply Current During Temperature Measurement Standby Current Conversion Time
ISC
1 conversion/s (conversion period 1 s), XENMCLKDIV=1, Rsensor = 4.5 k:, Max value at VDD = 3.6 V OSR=512 OSR=256 OSR=128 OSR=64 1 conversion/s (conversion period 1 s), XENMCLKDIV=1, Rsensor = 4.5 k:, Max value at VDD = 3.6 V OSR=512 OS R=256 OSR=128 OSR=64 1 conversion/s (conversion period 1 s), XENMCLKDIV=1, Rsensor = 4.5 k:, Max value at VDD = 3.6 V OSR=512 OSR=256 OSR=128 OSR=64 VDD = 2.35 V, Rsensor = 4.5 k:
0.5 0.25 0.13 0.07
0.9 0.5 0.3 0.2
A
1.6 0.8 0.5 0.3
2.5 1.3 0.7 0.4
A
0.9 0.5 0.3 0.2 0.52
1.5 0.8 0.4 0.3
A
mA
ISC
VDD = 2.35 V, Rsensor = 4.5 k: VDD = 2.35 V MCLK = 32768 Hz, XENMCLKDIV=1 OSR=512 OSR=256 OSR=128 OSR=64
0.19
mA
ISS tCONV
0.1
0.5
A
16.1 8.3 4.4 2.5
ms
Note: XENMCLKDIV refer to the I C serial interface control bits, see table 1 on page 5.
2
ELECTRICAL CHARACTERISTICS
TA = -20 C to +60 C, Typ TA = 25 C, VDD = 2.35 V, Rsensor = 4.5k: unless otherwise noted
o o o
Parameter Resolution
Symbol
Conditions ISR = 405 mV ISR =105 mV ISRLIN =324 mV, OSR = 512 ISRLIN = 84 mV, OSR = 512
Min
Typ 16 6.1 1.6 19.7 5.1 4 3 14 13 12 10 32768
Max
Unit Bit V V LSB LSB Bit
Accuracy Intergral Nonlinearity Differential Nonlinearity ENOB (Effective Number of Bits) INL DNL
ISRLIN = 324 mV OSR=512 OSR=256 OSR=128 OSR=64 MCLK tD E L MCLK = 32768 Hz 30000 0.1
External Clock Signal Delay Between End of Conversion and ADC Result Read-Out Duty Cycle of MCLK
35000
Hz ms
DUTYC
Master Clock Division Enabled XENMCLKDIV=0 Master Clock Division Disabled XENMCLKDIV=1 ISCR = 1 (Water sensor) ISCR = 0 (Air sensor) ISCR = 1 (Water sensor) ISCR = 0 (Air sensor)
60/40 TBD
50/50
40/60 TBD 500
%
Serial Data Clock Input Signal Conversion Range Linear Input Signal Conversion Range Output Code Values Temperature Measurement Resistors
SCL ISR ISRLIN
405 105 324 84 0 -10% 7710 17000 3073 17000 -350 65408 +10%
kHz mV mV
Temperature Measurement Resistors Temp Coefficient
2
R1 R2 R3 R TCR
:
-400
-300
ppm / C
Note: ISCR refer to the I C serial interface control bits, see table 1 on page 5. TBD= To Be Defined
H28 CONTROL REGISTER
Table 1. HT2801 control register bit description Bit Number 7-6 Bit Name OSRS(1:0) Description Over Sampling Ratio (OSR) selection Value 11 01 10 00 0 1 1 0 1 0 2 1 0 XENMCLKDIV XOSENABLE OSSELECT Enable Master Clock Division Enable offset Offset value selection 0 1 0 1 1 0 Function OSR = 512 OSR = 256 OSR = 128 OSR = 64 No Conversion Start Conversion Pressure configuration Temperature configuration Water sensor:405 mV (324 mV linear range) Air sensor: 105 mV (84 mV linear range) MCLK division enabled MCLK division disabled Offset enabled Offset disabled Offset for water sensor +25 mV Offset for air sensor +33 mV
5 4 3
SCO PTS ISCR
Start Conversion Pressure/Temperature Selection Input Signal Conversion Range
H28 has one control register for configuring the measurement setup. See table 1 for control register bit definitions. Control register values are set via I2C bus. First two OSRS bits of the control register define four selectable over sampling ratios. The higher over sampling ratio the better ADC accuracy, but the longer conversion time. The SCO bit controls the A/D conversion. When SCO = 0, no A/D conversion takes place. When SCO = 1, the A/D converter turns on and the analog data is being converted. Then MCLK must be clocked at least until EOC pin goes high indicating that conversion has been accomplished. PTS bit selects between pressure and temperature measurement. In temperature measurement the sensor is connected in bridge configuration together with four integrated resistors (see figure 3 on page 8 and resistors R1, R2, R3 and R4). ISCR selects between two A/D conversion ranges. Wider range is matched for water pressure sensor and narrower range for air pressure sensor. The XENMCLKDIV bit controls the internal clock
frequency of H28, fCLK(INT). When the bit is low, the MCLK division is enabled and the internal clock frequency fCLK(INT) = fMCLK/2, where fMCLK is the master clock frequency. When the XENMCLKDIV bit is high, the MCLK division is disabled and fCLK(INT) = fMCLK. In the XENMCLKDIV = 1 mode the duty cycle should be as close to 50 % as possible. In this mode, the conversion time is made half (see page 3 conversion time values with XENMCLKDIV = 1) compared to clock speed division mode XENMCLKDIV = 0 whereas the resolution remains unchanged. In XENMCLKDIV = 0 mode the conversion time and also current consumption are doubled but then the external master clock signal MCLK does not need to have close to 50% duty cycle. XOSENABLE can be used to enable input signal range offset option. At 1 value no offset is applied but at 0 value an offset value which is determined with OSSELECT bit is used. OSSELECT selects between two offset values. Larger value is matched for water pressure sensor and smaller value is for air pressure sensor. No offset is applied if offset is disabled (XOSENABLE=1).
I 2C SERIAL INTERFACE CONTROL
Serial Interface H28 has two wire serial I2C bus type interface comprising of serial clock (SCL) and serial data (SDA) pins. I2C bus is used to write configuration data to sensor interface IC and read the measurement result when A/D conversion has been finished. Digital interface includes also master clock (MCLK), end of conversion (EOC) and master reset (XCLR) pins. MLCK signal is needed to be clocked during conversion period. It can be stopped after EOC goes high which indicates that A/D conversion has Device and Register Addresses I2C bus standard makes it possible to connect several I2C bus devices into same bus. The devices are distinguished from each other by unique device address codes. H28 device Table 2. H28 device address A7 1 A6 1 A5 1 A4 0 A3 1 A2 1 A1 1 W/R 0/1 Control register bits are described in table 1 (page 4). Two other 8-bit registers are used to store the 16-bit A/D conversion result. address is shown in table 2. The LSB bit of the device address defines whether the bus is configured to Read (1) or Write (0) operation. been accomplished. MCLK signal can also be running all the time. XCLR is used to reset the A/D converter. Reset initializes internal registers and counters. After connecting supply voltage to H28 and before starting operating the device via I2C bus it is required to reset the device with XCLR reset pin if supply voltage rise time has been longer than 400 ns. If the supply voltage rise time is shorter than this the external reset with XCLR pin is unnecessary since the device is automatically resetted by power on reset (POR) circuitry.
H28 contains three 8-bit registers which are presented in table 3. Control register is used to configure the device to proper measurement setup. Table 3. H28 internal register addresses
A7 1 1 1
A6 1 1 1
A5 1 1 1
A4 1 1 1
A3 1 1 1
A2 1 1 1
A1 0 1 1
A0 1 0 1
Register Description MSB A/D Conversion Result Register LSB A/D Conversion Result Register Control register
I 2C SERIAL INTERFACE CONTROL...
I2C Bus Protocol Definitions Two wire I2C bus protocol has special bus signal conditions. Figure 2 shows start (S), stop (P) and binary data conditions. At start condition the SCL is high and SDA has falling edge. At stop condition
A/D Conversion A/D conversion is progressed by running MCLK signal until EOC goes high indicating that conversion is done and data is ready for reading. the SCL is also high but SDA has rising edge. Data must be held stable in SDA pin when SCL is high. Data can change value at SDA pin only when SCL is low. SDA for one SCL clock cycle. At not acknowledge (N) the slave device sends 0 bit to SDA (pulls down SDA) for one SCL clock cycle.
Figure 2. I2C protocol definitions I2C contains also acknowledge (A) and not acknowledge (N) commands. At acknowledge the master device sends 0 bit to SDA bus (pulls down Abbreviations: A= Acknowledge by Slave N = Not Acknowledge by Master Conversion Starting - Write Sequence Conversion is started by first writing measurement configuration bits into the control register. Write sequence is illustrated in Table 4. Table 4. H28 I2C bus write sequence bits S AW A AC A DC A P
S = Start P = Stop
To start conversion the control register SCO bit has to be set high (SCO=1, see control register bit description in table 1).
Abbreviations: AW = Device Write Address (%1110 1110) AR = Device Read Address (%1110 1111) AC = Control Register Address (%1111 1111) Ax = MSB (x=M, %1111 1101) or LSB (x=L, %1111 1110) ADC Result Register Address Each I2C bus operation like write starts with start command (see figure 2). After start the H28 device address with write bit (AW, see table 2) is sent and ended to acknowledge (A). After this control register address (AC, see table 3) is sent
DC = Control Register Data Dx = MSB (x=M) or LSB (x=L) A/D Result Register Data
and ended to acknowledge (A). Next control register data (DC, see table 1) is written and ended to acknowledge (A). Finally the I2C bus operation is ended with stop command (see figure 2).
I 2C SERIAL INTERFACE CONTROL
Conversion Result - Read Sequence Table 5 presents general control sequence for single register data read. Table 5 H28 I2C bus single register (address Ax)
Table 6 presesents control sequence for reading the 16-bit A/D conversion result from both MSB and LSB data registers. LSB register data (DL) can be read right after MSB register data (DM) read since in case the read sequence is continued (not ended to stop condition P) the register address is automatically incremented to point to next register address (in this case to point to the LSB data register).
Table 6 H28 I2C bus MSB (first) and LSB (second) A/D conversion result read sequence
Accuracy Improvement - Averaging Averaging technique can be used to remove conversion error caused by noise and thus improve measurement accuracy. By accomplishing several A/D conversions and taking average of the samples, it is possible to average out noise. Theoretically noise is reduced by factor N where N is number of averaged samples. Converter non-linearities cannot be removed by averaging.
APPLICATION INFORMATION
Figure 3. Resistive sensor connection circuit Together with a resistive pressure sensor, H28 can be used in pressure measurement applications. Control can be performed with a micro-controller through the I2C serial interface. The sensor is connected between the power supply voltage (VDD) and H28 signal ground (COMMON) which can be internally (switch inside of H28) connected to ground (GND). Sensor output is read as a differential signal through PI (positive input) and NI (negative input) to the converter in H28. In the pressure measurement mode, the switches marked "P" are closed and the sensor output is fed through to the ADC. In the temperature measurement mode, the switches marked "T" are closed and the voltage at the ADC input is determined by the internal resistor array and the temperature-dependent resistance of the sensor. In this configuration the sensor bridge is connected as part of single four resistor bridge circuit where other four resistors (R1, R2, R3, R4) are inside the IC. To guarantee conversion accuracy a supply voltage decoupling capacitor of 4.7 F or more should be placed between VDD and GND of H28 (see CV D D in figure 3).
H28 PAD LAYOUT
PIN LAYOUT
This document may contain preliminary information and is subject to change by Hope Microelectronics without notice. Hope Microelectronics assumes no responsibility or liability for any use of the information contained herein. Nothing in this document shall HOPE MICROELECTRONICS CO.,LTD 4/F, Block B3, East Industrial Area, Huaqiaocheng, Shenzhen, Guangdong, China Tel: Fax: Email: 86-755-86096602 86-755-86096587 sales@hoperf.com http://www.hoperf.cn http://hoperf.en.alibaba.com
(c)2006, HOPE MICROELECTRONICS CO.,LTD. All rights reserved.
operate as an express or implied license or indemnity under the intellectual property rights of Hope Microelectronics or third parties. The products described in this document are not intended for use in implantation or other direct life support applications where malfunction may result in the direct physical harm or injury to persons. NO WARRANTIES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MECHANTABILITY OR FITNESS FOR A ARTICULAR PURPOSE, ARE OFFERED IN THIS DOCUMENT.
Website: http://www.hoperf.com


▲Up To Search▲   

 
Price & Availability of H28

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X