 OC-3/STM-1 SFP Multimode Transceivers with Digital Diagnostics
TRPA03MM
Product Description The TRPA03MM SFP fiber optic transceivers with integrated digital diagnostics monitoring functionality provide a quick and reliable interface for OC-3/STM-1 multimode applications. The diagnostic monitoring functions, alarm and warning features are provided via an I2C serial interface. The transceivers are designed to be compatible with the ATM requirements at OC-3/STM-1 (156Mb/s) data rate. The TRPA03MM transceivers connect to standard 20-pad SFP connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing the power supply from the host system. The transmitter design incorporates a highly reliable 1310nm LED and an integrated driver circuit. The receiver features a transimpedance amplifier IC for high sensitivity and wide dynamic range. The transmitter and receiver DATA interfaces are AC-coupled internally. LV-TTL Transmitter Disable control input and Loss of Signal output interfaces are also provided. The transceivers operate from a single +3.3V power supply over three operating case temperature ranges of -5C to +70C ("B" option), -5C to +85C ("E" option) or -40C to +85C ("A" option). The housing is made of plastic and metal for EMI enhancement.
Features Compatible with SFP MSA Compatible with ANSI-T1.646, ATM and Specifications for OC-3/STM-1 (156Mb/s) Digital Diagnostics Monitoring through Serial Interface Distances up to 2km Hot-pluggable Loss of Signal Output TX Disable Input Duplex LC Optical Interface Single +3.3V Power Supply
Absolute Maximum Ratings
Parameter Storage Temperature "B" option Operating Case Temperature Supply Voltage Input Voltage
1
Symbol Tst
Minimum - 40 -5 -5 - 40 0 0
Maximum + 85 + 70 + 85 + 85 + 5.0 Vcc
Units C C V V
1
"E" option "A" option
Top Vcc Vin
Measured on top side of SFP module at the front center vent hole of the cage.
An Oplink Company
RevC-P.2009.04.02
TRPA03MM
Transmitter Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate Parameter Operating Data Rate 1 Optical Output Power Center Wavelength Spectral Width (FWHM) Optical Rise and Fall Time (10% to 90%) Extinction Ratio Transmitter OFF Power Systematic Jitter (DCD & DDJ, peak-to-peak) Random Jitter (peak-to-peak)
1 2
Symbol B PO C FWHM tr, tf Phi/Plo POFF SJ RJ
Minimum - 20.0 1270 10 -
Typical 156 2.5 -
Maximum - 14.0 1380 200 3.0 - 45.0 1.6 0.6
Units Mb/s dBm nm nm ns dB dBm ns ns
2
Data rate ranges from 50Mb/s to 266Mb/s. However, some degradation may be incurred in overall performance. Measured average power coupled into 62.5/125m, 0.275 NA graded-index multimode fiber. The minimum power specified is at Beginning-of-Life.
Receiver Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
All parameters guaranteed only at typical data rate Parameter Operating Data Rate
1 -10 2
Symbol B Pmin Pmax Plos+ Plost_loss_off t_loss_on
Minimum - 30.0 - 14.0 - 45.0 0.5 1100
Typical 156 - 33.0 - 12.0 1.0 -
Maximum - 30.0 100 350 1600
Units Mb/s dBm dBm dBm dB s nm
Receiver Sensitivity (10 BER)
Maximum Input Optical Power (2.5x10-10 BER) 2 LOS Thresholds LOS Hysteresis LOS Timing Delay Increasing Light Input Decreasing Light Input Increasing Light Input Decreasing Light Input
Wavelength of Operation
1
Data rate ranges from 50Mb/s to 266Mb/s. However, some degradation may be incurred in overall performance. 2 Specified in average optical input power and measured at 156Mb/s and 1310nm wavelength with 223-1 PRBS. The sensitivity is guaranteed with eye opening of 1.23ns.
Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
Oplink Communications, Inc.
DATE OF MANUFACTURE: MANUFACTURED IN THE USA This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements
Oplink Communications, Inc.
2
RevC-P.2009.04.02
TRPA03MM
Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter Input Voltage Swing (TD+ & TD-) 1 Input HIGH Voltage (TX Disable) 2 Input LOW Voltage (TX Disable)
1 2
Symbol VPP-DIF VIH VIL
Minimum 0.25 2.0 0
Typical -
Maximum 2.4 VCC 0.8
Units V V V
2
Differential peak-to-peak voltage. There is an internal 4.7 to 10k pull-up resistor to VccT.
Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter Output Voltage Swing (RD+ & RD-) 1 Output HIGH Voltage (LOS) 2 Output LOW Voltage (LOS)
1 2
Symbol VPP-DIF VOH VOL
Minimum 0.6 2.0 0
Typical -
Maximum 2.0 VCC + 0.3 0.5
Units V V V
2
Differential peak-to-peak voltage across external 100 load. Open collector compatible, 4.7 to 10k pull-up resistor to Vcc (Host Supply Voltage).
Electrical Power Supply Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V)
Parameter Supply Voltage Supply Current Symbol VCC ICC Minimum 3.13 Typical 3.3 210 Maximum 3.47 245 Units V mA
Module Definition
MOD_DEF(0) pin 6 TTL LOW MOD_DEF(1) pin 5 SCL MOD_DEF(2) pin 4 SDA Interpretation by Host Serial module definition protocol
Electrical Pad Layout
20 19 18 17 16 15 14 13 12 11
TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND
Host Board Connector Pad Layout
1 2 3 4 5 6 7 8 9 10
TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND
1 2 3
Toward Bezel
20 19 18 17 16 15 14 13 12 11
Toward ASIC
4 5 6 7 8 9 10
Top of Board
Bottom of Board (as viewed thru top of board)
Pin 2 Internally Grounded.
Oplink Communications, Inc.
3
RevC-P.2009.04.02
TRPA03MM
Example of SFP host board schematic
Vcc 3.3V
1H coil or ferrite bead (<0.2 series resistance)
Vcc 3.3V
+
10
0.1
0.1
16 15 8 4 5 6
R
R
R
LOS MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) (100 to ground internally) RX DATA OUT+ to 50 load RX DATA OUTto 50 load
+
10
0.1
TRPA03MM
3
TX Disable
50 line
TX DATA IN+ TX DATA IN50 line
18 19
50 line
13
50 line
12
1, 9, 10, 11, 14, 17, 20
R: 4.7 to 10k
Application Notes
Electrical Interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10k resistor on the host board. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX Fault: Per SFP MSA, pin 2 is TX Fault. This transceiver is LED based and does not support TX Fault. Pin 2 is internally connected to transmitter circuit ground (TX GND) to indicate normal operation. TX Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power
up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP. The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are RPM (receiver power monitor), internal temperature and module supply voltage. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.3. Power Supply and Grounding: The power supply line should be well-filtered. All 0.1F power supply bypass capacitors should be as close to the transceiver module as possible.
Oplink Communications, Inc.
4
RevC-P.2009.04.02
TRPA03MM
Package Outline
56.7 2.23 REF
0 1.27 -0.13 .050 +.000 -.005
0 0.98 -0.13 +.000 .038 -.005 1 .04
13.67 13.54 .54 .53
6.250.05 .246.002
FRONT EDGE OF TRANSCEIVER CAGE
47.3 1.861 8.51 .335
8.9 .350
46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com * www.oplink.com
13.90.2 .546.008
1.8 .07
41.80.15 1.646.006
450.20 1.771.008
Dimensions in inches [mm] Default tolerances: .xxx = .005", .xx = .01"
Ordering Information
Model Name
Operation Temperature
Latch Color
Nominal Wavelength
TRPA03MM3BAS TRPA03MM3EAS TRPA03MM3AAS
- 5C to +70C - 5C to +85C - 40C to +85C
Gray Gray Gray
1310nm 1310nm 1310nm
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink's Sales and Marketing for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. RevC-P.2009.04.02 (c) 2008, Oplink Communications, Inc. 5


▲Up To Search▲   

 
Price & Availability of TRPA03MM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X