  Datasheet File OCR Text:
 VSKU/V41, 56..PbF Series
Vishay High Power Products
Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules)
FEATURES
* High voltage * Industrial standard package * Thick Al metal die and double stick bonding * Thick copper baseplate * UL E78996 approved
ADD-A-PAKTM
RoHS
COMPLIANT
* 3500 VRMS isolating voltage * Totally lead (Pb)-free
PRODUCT SUMMARY
IT(AV) 45/60 A
* Designed and qualified for industrial level
BENEFITS MECHANICAL DESCRIPTION
The Generation 5 of ADD-A-PAKTM module combine the excellent thermal performance obtained by the usage of direct bonded copper substrate with superior mechanical ruggedness, thanks to the insertion of a solid copper baseplate at the bottom side of the device. The Cu baseplate allow an easier mounting on the majority of heatsink with increased tolerance of surface roughness and improved thermal spread. The Generation 5 of ADD-A-PAK module is manufactured without hard mold, eliminating in this way any possible direct stress on the leads. The electrical terminals are secured against axial pull-out: they are fixed to the module housing via a click-stop feature already tested and proved as reliable on other Vishay HPP modules. * Up to 1600 V * Full compatible TO-240AA * High surge capability * Easy mounting on heatsink * Al203 DBC insulator * Heatsink grounded
ELECTRICAL DESCRIPTION
These modules are intended for general purpose high voltage applications such as high voltage regulated power supplies, lighting circuits, temperature and motor speed control circuits, UPS and battery charger.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL IT(AV) IT(RMS) 50 Hz ITSM 60 Hz 50 Hz 60 Hz I2t VRRM TJ, TStg Range CHARACTERISTICS 85 C VSKU/V41 45 70 850 890 3.61 3.30 36.1 400 to 1600 - 40 to 125 VSKU/V56 60 95 A 1310 1370 8.50 7.82 85.0 kA2s V C kA2s UNITS
I2 t
Document Number: 94515 Revision: 25-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 1
VSKU/V41, 56..PbF Series
Vishay High Power Products
ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS
TYPE NUMBER VOLTAGE CODE 04 VSKU/V41, 56 08 12 16 VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V 400 800 1200 1600 VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 500 900 1300 1700 VDRM, MAXIMUM REPETITIVE PEAK OFF-STATE VOLTAGE, GATE OPEN CIRCUIT V 400 800 1200 1600 15 IRRM, IDRM AT 125 C mA
Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules)
ON-STATE CONDUCTION
PARAMETER Maximum average on-state current Maximum RMS on-state current SYMBOL IT(AV) IT(RMS) TEST CONDITIONS 180 conduction, half sine wave, TC = 85 C DC TC t = 10 ms t = 8.3 ms Maximum peak, one-cycle non-repetitive on-state current ITSM t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms Maximum I2t for fusing I2t t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms Maximum I2t for fusing Maximum value of threshold voltage Maximum value of on-state slope resistance I2t (1) VT(TO) (2) rt (2) Low level
(3)
VALUES VSKU/V41 45 70 82 850 VSKU/V56 60 95 80 1310 1370 1100 1150 1450 1520 8.56 7.82 6.05 5.53 10.05 9.60 85.6 0.85 0.88 3.53 3.41
UNITS A C
No voltage reapplied 100 % VRRM reapplied
Sinusoidal half wave, initial TJ = TJ maximum
890 715 750 940 985 3.61 3.30 2.56 2.33 4.42 4.03 36.1 0.88 0.91 5.90 5.74
A
TJ = 25 C, no voltage reapplied No voltage reapplied 100 % VRRM reapplied Initial TJ = TJ maximum
kA2s
TJ = 25 C, no voltage reapplied
t = 0.1 to 10 ms, no voltage reapplied High level (4) Low level (3) High level ITM = x IT(AV) IFM = x IF(AV)
(4)
kA2s V m
TJ = TJ maximum
Maximum peak on-state voltage
VTM
TJ = 25 C
1.81
1.54
V
Maximum non-repetitive rate of rise of turned on current Maximum holding current Maximum latching current
dI/dt
TJ = 25 C, from 0.67 VDRM, ITM = x IT(AV), Ig = 500 mA, tr < 0.5 s, tp > 6 s TJ = 25 C, anode supply = 6 V, resistive load, gate open circuit TJ = 25 C, anode supply = 6 V, resistive load
150
A/s
IH IL
200 400
mA
Notes (1) I2t for time t = I2t x t x x (2) Average power = V 2 T(TO) x IT(AV) + rt x (IT(RMS)) (3) 16.7 % x x I < I < x IAV AV (4) I > x I AV www.vishay.com 2 For technical questions, contact: ind-modules@vishay.com Document Number: 94515 Revision: 25-Apr-08
VSKU/V41, 56..PbF Series
Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK
TRIGGERING
PARAMETER Maximum peak gate power Maximum average gate power Maximum peak gate current Maximum peak negative gate voltage Maximum gate voltage required to trigger SYMBOL PGM PG(AV) IGM - VGM TJ = - 40 C VGT TJ = 25 C TJ = 125 C TJ = - 40 C Maximum gate current required to trigger Maximum gate voltage that will not trigger Maximum gate current that will not trigger IGT VGD IGD TJ = 25 C TJ = 125 C TJ = 125 C, rated VDRM applied Anode supply = 6 V resistive load TEST CONDITIONS VALUES 10 2.5 2.5 10 4.0 2.5 1.7 270 150 80 0.25 6 V mA mA V UNITS W A
BLOCKING
PARAMETER Maximum peak reverse and off-state leakage current at VRRM, VDRM RMS insulation voltage Maximum critical rate of rise of off-state voltage SYMBOL IRRM, IDRM VINS dV/dt (1) TEST CONDITIONS TJ = 125 C, gate open circuit 50 Hz, circuit to base, all terminals shorted TJ = 125 C, linear to 0.67 VDRM, gate open circuit VALUES 15 2500 (1 min) 3500 (1 s) 500 UNITS mA V V/s
Note (1) Available with dV/dt = 1000 V/s, to complete code add S90 i.e. VSKU41/16AS90
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER Junction operating and storage temperature range Maximum internal thermal resistance, junction to case per module Typical thermal resistance, case to heatsink to heatsink Mounting torque 10 % busbar Approximate weight Case style JEDEC SYMBOL TJ, TStg RthJC RthCS DC operation Mounting surface, flat, smooth and greased A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound. TEST CONDITIONS VALUES - 40 to 125 0.23 K/W 0.1 5 Nm 3 110 4 TO-240AA g oz. UNITS C
R CONDUCTION PER JUNCTION
DEVICES VSKU/V41 VSKU/V56 SINE HALF WAVE CONDUCTION 180 0.11 0.09 120 0.13 0.11 90 0.17 0.13 60 0.23 0.18 30 0.34 0.27 RECTANGULAR WAVE CONDUCTION 180 0.09 0.07 120 0.14 0.11 90 0.18 0.14 60 0.23 0.19 30 0.34 0.28 UNITS C/W
Note * Table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 3
VSKU/V41, 56..PbF Series
Vishay High Power Products
Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules)
Maximum Average On-state Power Loss (W) 100 DC 180 120 90 60 30
Maximum Allowable Case Temperature (C)
130 VSK.41.. Series R thJC (DC) = 0.46 K/W 120
80
110
Conduction Angle
60
RMS Limit
100 30 90 60 90 120 180
40
Conduction Period
20
VSK.41.. Series Per Junction TJ = 125C 0 20 40 60 80
80 0 10 20 30 40 50 Average On-state Current (A)
0 Average On-state Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 4 - On-State Power Loss Characteristics
Maximum Allowable Case Temperature (C)
VSK.41.. Series R thJC (DC) = 0.46 K/W
Peak Half Sine Wave On-state Current (A)
130
800
120
700
At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 125C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s
110
Conduction Period
600
100
30 60 90 120 180 DC
500
90
400 VSK.41.. Series Per Junction 300 1 10 100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
80 0 20 40 60 80 Average On-state Current (A)
Fig. 2 - Current Ratings Characteristics
Fig. 5 - Maximum Non-Repetitive Surge Current
Peak Half Sine Wave On-state Current (A)
Maximum Average On-state Power Loss (W)
70 60 50 40 30
Conduction Angle
900 800 700 600 500 400
180 120 90 60 30
RMS Limit
Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Control Of Conduction May Not Be Maintained. Initial TJ = 125C No Voltage Reapplied Rated VRRM Reapplied
20 10 0 0 10 20 30 40 50 Average On-state Current (A) VSK.41.. Series Per Junction TJ = 125C
VSK.41.. Series Per Junction 0.1 Pulse Train Duration (s) 1
300 0.01
Fig. 3 - On-State Power Loss Characteristics
Fig. 6 - Maximum Non-Repetitive Surge Current
www.vishay.com 4
For technical questions, contact: ind-modules@vishay.com
Document Number: 94515 Revision: 25-Apr-08
VSKU/V41, 56..PbF Series
Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK
350
SA R th
Maximum Total Power Loss (W)
2 0.
300
0. 3
W K/ K/ W
W K/ .1 =0
250 200 150 100 50 0 0 20 40
180 (Sine) 180 (Rect)
-D el
0.
5K /W
ta R
0. 7
K/ W 1K /W
2 x VSK.41.. Series Single Phase Bridge Connected T J = 125C 60 80
1.5 K/ W
100 0
20
40
60
80
100
120
140
Total Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 7 - On-State Power Loss Characteristics (Single Phase Bridge VSKU and VSKV)
350
R t hS
Maximum Total Power Loss (W)
300 250 Io 200 150 100 50 0 0 20 40 60 0 80 100 120 140 160 180 20 3 x VSK.41.. Series 6-Pulse Midpoint Connection Bridge T J = 125C
60 (Rect)
3 0. W K/
0. 5 K/ W
2 0. W K/
A
=0 W K/ .1 -D el t a R
0 .7
K/ W
1K /W
40
60
80
100
120
140
Total Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 8 - On-State Power Loss Characteristics
Maximum Allowable Case Temperature (C)
Maximum Allowable Case Temperature (C)
130 120 110
Conduction Angle
130 120 110
Conduction Period
VSK.56.. Series R thJC (DC) = 0.40 K/W
VSK.56.. Series R thJC (DC) = 0.40 K/W
100 90 30 80 70 0 10 20 30 40 50 60 70 Average On-state Current (A) 60 90 120
100 90 80 30 70 0 20 40 60 80 100 Average On-state Current (A) 60 90 120 180 DC
180
Fig. 9 - Current Ratings Characteristics
Fig. 10 - Current Ratings Characteristics
Document Number: 94515 Revision: 25-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 5
VSKU/V41, 56..PbF Series
Vishay High Power Products
Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules)
Peak Half Sine Wave On-state Current (A) 1200 1100 1000 900 800 700 600 500 1 10 100
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Maximum Average On-state Power Loss (W)
90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 Average On-state Current (A)
Conduction Angle
180 120 90 60 30 RMS Limit
At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 125C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s
VSK.56.. Series Per Junction TJ = 125C
VSK.56.. Series Per Junction
Fig. 11 - On-State Power Loss Characteristics
Fig. 13 - Maximum Non-Repetitive Surge Current
Maximum Average On-state Power Loss (W)
Peak Half Sine Wave On-state Current (A)
120 100 80 60 40 20 0 0 20 40 60 80 100 Average On-state Current (A) DC 180 120 90 60 30
1400
1200
1000
Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Control Of Conduction May Not Be Maintained. Initial TJ = 125C No Voltage Reapplied Rated VRRMReapplied
RMS Limit
Conduction Period
800
VSK.56.. Series Per Junction TJ = 125C
600 VSK.56.. Series Per Junction 400 0.01 0.1 Pulse Train Duration (s) 1
Fig. 12 - On-State Power Loss Characteristics
Fig. 14 - Maximum Non-Repetitive Surge Current
450 Maximum Total Power Loss (W) 400 350 300 250 200 150 100 50 0 0 20 40 60 80 100 120 0 140 20 40 60 80 100 120 140 Total Output Current (A) Maximum Allowable Ambient Temperature (C) 2 x VSK.56.. Series Single Phase Bridge Connected T J = 125C
180 (Sine) 180 (Rect)
0. 2 K/ W
R th
SA
= /W 1K 0. -D
0 .3
e lt
K/ W
a R
0.5 K/ W 0.7 K/ W 1 K/ W
2 K/ W
Fig. 15 - On-State Power Loss Characteristics (Single Phase Bridge VSKU and VSKV)
www.vishay.com 6
For technical questions, contact: ind-modules@vishay.com
Document Number: 94515 Revision: 25-Apr-08
VSKU/V41, 56..PbF Series
Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK
450
Rt
Maximum Total Power Loss (W)
400
2 0.
A hS
.1 =0
350 300 250 200 150 100 50 0 0 50 100 Io
/ KW
60 (Rect)
W K/
0.
3
K/ W
-D e lt a R
0.5
K/ W
0.7
K/ W
3 x VSK.56.. Series 6-Pulse Midpoint Connection Bridge T J = 125C 150 200
1 K/ W
250 0
20
40
60
80
100
120
140
Total Output Current (A)
Maximum Allowable Ambient Temperature (C)
Fig. 16 - On-State Power Loss Characteristics
1000
Maximum Reverse Recovery Charge - Qrr (C)
500 450 400 350 300 250 200
10 A 20 A
Instantaneous On-state Current (A)
VSK.41.. Series VSK.56.. Series TJ = 125 C
I TM = 200 A 100 A
100
50 A
TJ = 25C 10 TJ = 125C VSK.41.. Series Per Junction 1 0 1 2 3 4 5 6 7 Instantaneous On-state Voltage (V)
150 100 10
20
30
40
50
60
70
80
90 100
Rate Of Fall Of On-state Current - di/dt (A/s)
Fig. 17 - On-State Voltage Drop Characteristics
Fig. 19 - Recovery Charge Characteristics
1000
Maximum Reverse Recovery Current - Irr (A)
110 100
I TM = 200 A 100 A
Instantaneous On-state Current (A)
90 80 70 60 50 40 30 10
50 A 20 A 10 A
100
T = 25C J 10
T = 125C J VSK.56.. Series Per Junction
VSK.41.. Series VSK.56.. Series TJ = 125 C 20 30 40 50 60 70 80 90 100
1 0.5
1
1.5
2
2.5
3
3.5
4
4.5
Instantaneous On-state Voltage (V)
Rate Of Fall Of Forward Current - di/dt (A/s)
Fig. 18 - On-State Voltage Drop Characteristics
Fig. 20 - Recovery Current Characteristics
Document Number: 94515 Revision: 25-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 7
VSKU/V41, 56..PbF Series
Vishay High Power Products
Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules)
1 Transient Thermal Impedance Z thJC (K/W) Steady State Value: R thJC = 0.46 K/W R thJC = 0.40 K/W (DC Operation) 0.1 VSK.41.. Series VSK.56.. Series
Per Junction
0.01 0.001
0.01
0.1 Square Wave Pulse Duration (s)
1
10
Fig. 21 - Thermal Impedance ZthJC Characteristics
100
Instantaneous Gate Voltage (V)
Rectangular gate pulse a)Recommended load line for rated di/dt: 20 V, 30 ohms tr = 0.5 s, tp >= 6 s b)Recommended load line for <= 30% rated di/dt: 20 V, 65 ohms 10 tr = 1 s, tp >= 6 s
(1) PGM = 100 W, tp = 500 s (2) PGM = 50 W, tp = 1 ms (3) PGM = 20 W, tp = 25 ms (4) PGM = 10 W, tp = 5 ms
(a) (b)
TJ = -40 C TJ = 25 C
TJ = 125 C
1
(4) (3)
(2) (1)
VGD IGD 0.1 0.001 0.01
VSK.41../.56.. Series Frequency Limited by PG(AV) 0.1 1 10 100 1000
Instantaneous Gate Current (A)
Fig. 22 - Gate Characteristics
www.vishay.com 8
For technical questions, contact: ind-modules@vishay.com
Document Number: 94515 Revision: 25-Apr-08
VSKU/V41, 56..PbF Series
Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK
ORDERING INFORMATION TABLE
Device code
VSK
1 1 2 -
U
2
56
3
/
16
4
P
5
Module type Circuit configuration: U = Two SCR common cathode V = Two SCR common anode
3 4 5
-
Current code Voltage code (see Voltage Ratings table) P = Lead (Pb)-free
Note * To order the optional hardware go to www.vishay.com/doc?95172
CIRCUIT CONFIGURATION
VSKU...
(1)
VSKV...
(1)
+
-
(2)
+
(2)
(3) G1 K1 (4) (5) K2 G2 (7) (6) G1 K1 (4) (5)
(3)
+
K2 G2 (7) (6)
LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95087
Document Number: 94515 Revision: 25-Apr-08
For technical questions, contact: ind-modules@vishay.com
www.vishay.com 9
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000 Revision: 18-Jul-08
www.vishay.com 1


▲Up To Search▲   

 
Price & Availability of VSKU5616P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X