![]() |
|
| If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
|
| Datasheet File OCR Text: |
| VSKU/V41, 56..PbF Series Vishay High Power Products Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules) FEATURES * High voltage * Industrial standard package * Thick Al metal die and double stick bonding * Thick copper baseplate * UL E78996 approved ADD-A-PAKTM RoHS COMPLIANT * 3500 VRMS isolating voltage * Totally lead (Pb)-free PRODUCT SUMMARY IT(AV) 45/60 A * Designed and qualified for industrial level BENEFITS MECHANICAL DESCRIPTION The Generation 5 of ADD-A-PAKTM module combine the excellent thermal performance obtained by the usage of direct bonded copper substrate with superior mechanical ruggedness, thanks to the insertion of a solid copper baseplate at the bottom side of the device. The Cu baseplate allow an easier mounting on the majority of heatsink with increased tolerance of surface roughness and improved thermal spread. The Generation 5 of ADD-A-PAK module is manufactured without hard mold, eliminating in this way any possible direct stress on the leads. The electrical terminals are secured against axial pull-out: they are fixed to the module housing via a click-stop feature already tested and proved as reliable on other Vishay HPP modules. * Up to 1600 V * Full compatible TO-240AA * High surge capability * Easy mounting on heatsink * Al203 DBC insulator * Heatsink grounded ELECTRICAL DESCRIPTION These modules are intended for general purpose high voltage applications such as high voltage regulated power supplies, lighting circuits, temperature and motor speed control circuits, UPS and battery charger. MAJOR RATINGS AND CHARACTERISTICS SYMBOL IT(AV) IT(RMS) 50 Hz ITSM 60 Hz 50 Hz 60 Hz I2t VRRM TJ, TStg Range CHARACTERISTICS 85 C VSKU/V41 45 70 850 890 3.61 3.30 36.1 400 to 1600 - 40 to 125 VSKU/V56 60 95 A 1310 1370 8.50 7.82 85.0 kA2s V C kA2s UNITS I2 t Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 1 VSKU/V41, 56..PbF Series Vishay High Power Products ELECTRICAL SPECIFICATIONS VOLTAGE RATINGS TYPE NUMBER VOLTAGE CODE 04 VSKU/V41, 56 08 12 16 VRRM, MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE V 400 800 1200 1600 VRSM, MAXIMUM NON-REPETITIVE PEAK REVERSE VOLTAGE V 500 900 1300 1700 VDRM, MAXIMUM REPETITIVE PEAK OFF-STATE VOLTAGE, GATE OPEN CIRCUIT V 400 800 1200 1600 15 IRRM, IDRM AT 125 C mA Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules) ON-STATE CONDUCTION PARAMETER Maximum average on-state current Maximum RMS on-state current SYMBOL IT(AV) IT(RMS) TEST CONDITIONS 180 conduction, half sine wave, TC = 85 C DC TC t = 10 ms t = 8.3 ms Maximum peak, one-cycle non-repetitive on-state current ITSM t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms Maximum I2t for fusing I2t t = 10 ms t = 8.3 ms t = 10 ms t = 8.3 ms Maximum I2t for fusing Maximum value of threshold voltage Maximum value of on-state slope resistance I2t (1) VT(TO) (2) rt (2) Low level (3) VALUES VSKU/V41 45 70 82 850 VSKU/V56 60 95 80 1310 1370 1100 1150 1450 1520 8.56 7.82 6.05 5.53 10.05 9.60 85.6 0.85 0.88 3.53 3.41 UNITS A C No voltage reapplied 100 % VRRM reapplied Sinusoidal half wave, initial TJ = TJ maximum 890 715 750 940 985 3.61 3.30 2.56 2.33 4.42 4.03 36.1 0.88 0.91 5.90 5.74 A TJ = 25 C, no voltage reapplied No voltage reapplied 100 % VRRM reapplied Initial TJ = TJ maximum kA2s TJ = 25 C, no voltage reapplied t = 0.1 to 10 ms, no voltage reapplied High level (4) Low level (3) High level ITM = x IT(AV) IFM = x IF(AV) (4) kA2s V m TJ = TJ maximum Maximum peak on-state voltage VTM TJ = 25 C 1.81 1.54 V Maximum non-repetitive rate of rise of turned on current Maximum holding current Maximum latching current dI/dt TJ = 25 C, from 0.67 VDRM, ITM = x IT(AV), Ig = 500 mA, tr < 0.5 s, tp > 6 s TJ = 25 C, anode supply = 6 V, resistive load, gate open circuit TJ = 25 C, anode supply = 6 V, resistive load 150 A/s IH IL 200 400 mA Notes (1) I2t for time t = I2t x t x x (2) Average power = V 2 T(TO) x IT(AV) + rt x (IT(RMS)) (3) 16.7 % x x I < I < x IAV AV (4) I > x I AV www.vishay.com 2 For technical questions, contact: ind-modules@vishay.com Document Number: 94515 Revision: 25-Apr-08 VSKU/V41, 56..PbF Series Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK TRIGGERING PARAMETER Maximum peak gate power Maximum average gate power Maximum peak gate current Maximum peak negative gate voltage Maximum gate voltage required to trigger SYMBOL PGM PG(AV) IGM - VGM TJ = - 40 C VGT TJ = 25 C TJ = 125 C TJ = - 40 C Maximum gate current required to trigger Maximum gate voltage that will not trigger Maximum gate current that will not trigger IGT VGD IGD TJ = 25 C TJ = 125 C TJ = 125 C, rated VDRM applied Anode supply = 6 V resistive load TEST CONDITIONS VALUES 10 2.5 2.5 10 4.0 2.5 1.7 270 150 80 0.25 6 V mA mA V UNITS W A BLOCKING PARAMETER Maximum peak reverse and off-state leakage current at VRRM, VDRM RMS insulation voltage Maximum critical rate of rise of off-state voltage SYMBOL IRRM, IDRM VINS dV/dt (1) TEST CONDITIONS TJ = 125 C, gate open circuit 50 Hz, circuit to base, all terminals shorted TJ = 125 C, linear to 0.67 VDRM, gate open circuit VALUES 15 2500 (1 min) 3500 (1 s) 500 UNITS mA V V/s Note (1) Available with dV/dt = 1000 V/s, to complete code add S90 i.e. VSKU41/16AS90 THERMAL AND MECHANICAL SPECIFICATIONS PARAMETER Junction operating and storage temperature range Maximum internal thermal resistance, junction to case per module Typical thermal resistance, case to heatsink to heatsink Mounting torque 10 % busbar Approximate weight Case style JEDEC SYMBOL TJ, TStg RthJC RthCS DC operation Mounting surface, flat, smooth and greased A mounting compound is recommended and the torque should be rechecked after a period of 3 hours to allow for the spread of the compound. TEST CONDITIONS VALUES - 40 to 125 0.23 K/W 0.1 5 Nm 3 110 4 TO-240AA g oz. UNITS C R CONDUCTION PER JUNCTION DEVICES VSKU/V41 VSKU/V56 SINE HALF WAVE CONDUCTION 180 0.11 0.09 120 0.13 0.11 90 0.17 0.13 60 0.23 0.18 30 0.34 0.27 RECTANGULAR WAVE CONDUCTION 180 0.09 0.07 120 0.14 0.11 90 0.18 0.14 60 0.23 0.19 30 0.34 0.28 UNITS C/W Note * Table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 3 VSKU/V41, 56..PbF Series Vishay High Power Products Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules) Maximum Average On-state Power Loss (W) 100 DC 180 120 90 60 30 Maximum Allowable Case Temperature (C) 130 VSK.41.. Series R thJC (DC) = 0.46 K/W 120 80 110 Conduction Angle 60 RMS Limit 100 30 90 60 90 120 180 40 Conduction Period 20 VSK.41.. Series Per Junction TJ = 125C 0 20 40 60 80 80 0 10 20 30 40 50 Average On-state Current (A) 0 Average On-state Current (A) Fig. 1 - Current Ratings Characteristics Fig. 4 - On-State Power Loss Characteristics Maximum Allowable Case Temperature (C) VSK.41.. Series R thJC (DC) = 0.46 K/W Peak Half Sine Wave On-state Current (A) 130 800 120 700 At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 125C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s 110 Conduction Period 600 100 30 60 90 120 180 DC 500 90 400 VSK.41.. Series Per Junction 300 1 10 100 Number Of Equal Amplitude Half Cycle Current Pulses (N) 80 0 20 40 60 80 Average On-state Current (A) Fig. 2 - Current Ratings Characteristics Fig. 5 - Maximum Non-Repetitive Surge Current Peak Half Sine Wave On-state Current (A) Maximum Average On-state Power Loss (W) 70 60 50 40 30 Conduction Angle 900 800 700 600 500 400 180 120 90 60 30 RMS Limit Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Control Of Conduction May Not Be Maintained. Initial TJ = 125C No Voltage Reapplied Rated VRRM Reapplied 20 10 0 0 10 20 30 40 50 Average On-state Current (A) VSK.41.. Series Per Junction TJ = 125C VSK.41.. Series Per Junction 0.1 Pulse Train Duration (s) 1 300 0.01 Fig. 3 - On-State Power Loss Characteristics Fig. 6 - Maximum Non-Repetitive Surge Current www.vishay.com 4 For technical questions, contact: ind-modules@vishay.com Document Number: 94515 Revision: 25-Apr-08 VSKU/V41, 56..PbF Series Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK 350 SA R th Maximum Total Power Loss (W) 2 0. 300 0. 3 W K/ K/ W W K/ .1 =0 250 200 150 100 50 0 0 20 40 180 (Sine) 180 (Rect) -D el 0. 5K /W ta R 0. 7 K/ W 1K /W 2 x VSK.41.. Series Single Phase Bridge Connected T J = 125C 60 80 1.5 K/ W 100 0 20 40 60 80 100 120 140 Total Output Current (A) Maximum Allowable Ambient Temperature (C) Fig. 7 - On-State Power Loss Characteristics (Single Phase Bridge VSKU and VSKV) 350 R t hS Maximum Total Power Loss (W) 300 250 Io 200 150 100 50 0 0 20 40 60 0 80 100 120 140 160 180 20 3 x VSK.41.. Series 6-Pulse Midpoint Connection Bridge T J = 125C 60 (Rect) 3 0. W K/ 0. 5 K/ W 2 0. W K/ A =0 W K/ .1 -D el t a R 0 .7 K/ W 1K /W 40 60 80 100 120 140 Total Output Current (A) Maximum Allowable Ambient Temperature (C) Fig. 8 - On-State Power Loss Characteristics Maximum Allowable Case Temperature (C) Maximum Allowable Case Temperature (C) 130 120 110 Conduction Angle 130 120 110 Conduction Period VSK.56.. Series R thJC (DC) = 0.40 K/W VSK.56.. Series R thJC (DC) = 0.40 K/W 100 90 30 80 70 0 10 20 30 40 50 60 70 Average On-state Current (A) 60 90 120 100 90 80 30 70 0 20 40 60 80 100 Average On-state Current (A) 60 90 120 180 DC 180 Fig. 9 - Current Ratings Characteristics Fig. 10 - Current Ratings Characteristics Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 5 VSKU/V41, 56..PbF Series Vishay High Power Products Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules) Peak Half Sine Wave On-state Current (A) 1200 1100 1000 900 800 700 600 500 1 10 100 Number Of Equal Amplitude Half Cycle Current Pulses (N) Maximum Average On-state Power Loss (W) 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 Average On-state Current (A) Conduction Angle 180 120 90 60 30 RMS Limit At Any Rated Load Condition And With Rated VRRM Applied Following Surge. Initial TJ = 125C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s VSK.56.. Series Per Junction TJ = 125C VSK.56.. Series Per Junction Fig. 11 - On-State Power Loss Characteristics Fig. 13 - Maximum Non-Repetitive Surge Current Maximum Average On-state Power Loss (W) Peak Half Sine Wave On-state Current (A) 120 100 80 60 40 20 0 0 20 40 60 80 100 Average On-state Current (A) DC 180 120 90 60 30 1400 1200 1000 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Control Of Conduction May Not Be Maintained. Initial TJ = 125C No Voltage Reapplied Rated VRRMReapplied RMS Limit Conduction Period 800 VSK.56.. Series Per Junction TJ = 125C 600 VSK.56.. Series Per Junction 400 0.01 0.1 Pulse Train Duration (s) 1 Fig. 12 - On-State Power Loss Characteristics Fig. 14 - Maximum Non-Repetitive Surge Current 450 Maximum Total Power Loss (W) 400 350 300 250 200 150 100 50 0 0 20 40 60 80 100 120 0 140 20 40 60 80 100 120 140 Total Output Current (A) Maximum Allowable Ambient Temperature (C) 2 x VSK.56.. Series Single Phase Bridge Connected T J = 125C 180 (Sine) 180 (Rect) 0. 2 K/ W R th SA = /W 1K 0. -D 0 .3 e lt K/ W a R 0.5 K/ W 0.7 K/ W 1 K/ W 2 K/ W Fig. 15 - On-State Power Loss Characteristics (Single Phase Bridge VSKU and VSKV) www.vishay.com 6 For technical questions, contact: ind-modules@vishay.com Document Number: 94515 Revision: 25-Apr-08 VSKU/V41, 56..PbF Series Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK 450 Rt Maximum Total Power Loss (W) 400 2 0. A hS .1 =0 350 300 250 200 150 100 50 0 0 50 100 Io / KW 60 (Rect) W K/ 0. 3 K/ W -D e lt a R 0.5 K/ W 0.7 K/ W 3 x VSK.56.. Series 6-Pulse Midpoint Connection Bridge T J = 125C 150 200 1 K/ W 250 0 20 40 60 80 100 120 140 Total Output Current (A) Maximum Allowable Ambient Temperature (C) Fig. 16 - On-State Power Loss Characteristics 1000 Maximum Reverse Recovery Charge - Qrr (C) 500 450 400 350 300 250 200 10 A 20 A Instantaneous On-state Current (A) VSK.41.. Series VSK.56.. Series TJ = 125 C I TM = 200 A 100 A 100 50 A TJ = 25C 10 TJ = 125C VSK.41.. Series Per Junction 1 0 1 2 3 4 5 6 7 Instantaneous On-state Voltage (V) 150 100 10 20 30 40 50 60 70 80 90 100 Rate Of Fall Of On-state Current - di/dt (A/s) Fig. 17 - On-State Voltage Drop Characteristics Fig. 19 - Recovery Charge Characteristics 1000 Maximum Reverse Recovery Current - Irr (A) 110 100 I TM = 200 A 100 A Instantaneous On-state Current (A) 90 80 70 60 50 40 30 10 50 A 20 A 10 A 100 T = 25C J 10 T = 125C J VSK.56.. Series Per Junction VSK.41.. Series VSK.56.. Series TJ = 125 C 20 30 40 50 60 70 80 90 100 1 0.5 1 1.5 2 2.5 3 3.5 4 4.5 Instantaneous On-state Voltage (V) Rate Of Fall Of Forward Current - di/dt (A/s) Fig. 18 - On-State Voltage Drop Characteristics Fig. 20 - Recovery Current Characteristics Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 7 VSKU/V41, 56..PbF Series Vishay High Power Products Thyristor/Thyristor, 45/60 A (ADD-A-PAKTM Generation 5 Power Modules) 1 Transient Thermal Impedance Z thJC (K/W) Steady State Value: R thJC = 0.46 K/W R thJC = 0.40 K/W (DC Operation) 0.1 VSK.41.. Series VSK.56.. Series Per Junction 0.01 0.001 0.01 0.1 Square Wave Pulse Duration (s) 1 10 Fig. 21 - Thermal Impedance ZthJC Characteristics 100 Instantaneous Gate Voltage (V) Rectangular gate pulse a)Recommended load line for rated di/dt: 20 V, 30 ohms tr = 0.5 s, tp >= 6 s b)Recommended load line for <= 30% rated di/dt: 20 V, 65 ohms 10 tr = 1 s, tp >= 6 s (1) PGM = 100 W, tp = 500 s (2) PGM = 50 W, tp = 1 ms (3) PGM = 20 W, tp = 25 ms (4) PGM = 10 W, tp = 5 ms (a) (b) TJ = -40 C TJ = 25 C TJ = 125 C 1 (4) (3) (2) (1) VGD IGD 0.1 0.001 0.01 VSK.41../.56.. Series Frequency Limited by PG(AV) 0.1 1 10 100 1000 Instantaneous Gate Current (A) Fig. 22 - Gate Characteristics www.vishay.com 8 For technical questions, contact: ind-modules@vishay.com Document Number: 94515 Revision: 25-Apr-08 VSKU/V41, 56..PbF Series Thyristor/Thyristor, 45/60 A Vishay High Power Products TM Generation 5 Power Modules) (ADD-A-PAK ORDERING INFORMATION TABLE Device code VSK 1 1 2 - U 2 56 3 / 16 4 P 5 Module type Circuit configuration: U = Two SCR common cathode V = Two SCR common anode 3 4 5 - Current code Voltage code (see Voltage Ratings table) P = Lead (Pb)-free Note * To order the optional hardware go to www.vishay.com/doc?95172 CIRCUIT CONFIGURATION VSKU... (1) VSKV... (1) + - (2) + (2) (3) G1 K1 (4) (5) K2 G2 (7) (6) G1 K1 (4) (5) (3) + K2 G2 (7) (6) LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95087 Document Number: 94515 Revision: 25-Apr-08 For technical questions, contact: ind-modules@vishay.com www.vishay.com 9 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1 |
|
Price & Availability of VSKU5616P
|
|
|
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
| [Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
|
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |