 BCR30AM
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Triac
30 Ampere/400-600 Volts
OUTLINE DRAWING
C D G E H J K

L M
A
Description: A triac is a solid state silicon AC switch which may be gate triggered from an off-state to an on-state for either polarity of applied voltage. Features: Planar Passivation
F
B
P
K
N
Q
R
Selected for Inductive Loads Applications: Contactless AC Switches
CONNECTION DIAGRAM

Microwave Ovens Motor Controls Lighting Controls Ordering Information: Example: Select the complete eight, nine or ten digit part number you desire from the table - i.e. BCR30AM-8 is a 400 Volt, 30 Ampere Triac.
Type VDRM Volts 400 600 Code -8 -12 Inductive Load* L
T1 TERMINAL T2 TERMINAL GATE T2 TERMINAL
Outline Drawing (Conforms to TO-3P) Dimensions A B C D E F G H Inches 0.79 0.77 0.63 0.20 0.16 0.08 0.13 Dia. 0.08 Millimeters 20.0 19.5 15.9 5.0 4.0 2.0 3.2 Dia. 2.0 Dimensions J K L M N P Q R Inches 0.04 0.21 0.18 0.06 0.02 0.17 0.11 0.16 Millimeters 1.0 5.45 4.5 1.5 0.6 4.4 2.8 4.0
BCR30AM
*For inductive load, add L.
T-87
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR30AM Triac 30 Ampere/400-600 Volts
Absolute Maximum Ratings, Ta = 25 C unless otherwise specified
Ratings On-state Current, Tc = 75C Repetitive Peak Off-state Voltage (Gate Open) Non-repetitive Peak Off-state Voltage (Gate Open) Non-repetitive Peak On-state Voltage, One Cycle (60 Hz) I2t for Fusing, t = 8.3 msec Peak Gate Power Dissipation, 20 sec Average Gate Power Dissipation Peak Gate Current Peak Gate Voltage Storage Temperature Operating Temperature Weight Symbol IT(RMS) VDRM VDSM ITSM I2t PGM PG(avg) IGM VGM Tstg Tj - BCR30AM-8 30 400 500 300 378 5 0.5 2 10 -40 to 125 -40 to 125 4.8 BCR30AM-12 30 600 720 300 378 5 0.5 2 10 -40 to 125 -40 to 125 4.8 Units Amperes Volts Volts Amperes A2sec Watts Watts Amperes Volts C C Grams
Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified
Characteristics Gate Parameters DC Gate Trigger Current MT2+ Gate+ MT2+ Gate- MT2- Gate- DC Gate Trigger Voltage MT2+ Gate+ MT2+ Gate- MT2- Gate- DC Gate Non-trigger Voltage All VGD 1/2 VDRM - - 125C 0.2 - - Volts VFGT I VRGT I VRGT III 6V 6V 6V 6 6 6 330 330 330 25C 25C 25C - - - - - - 2.5 2.5 2.5 Volts Volts Volts IFGT I IRGT I IRGT III 6V 6V 6V 6 6 6 330 330 330 25C 25C 25C - - - - - - 50 50 50 mA mA mA Symbol VD Test Conditions (Trigger Mode) RL RG Tj BCR30GM Min. Typ. Max. Units
Characteristics Thermal Resistance, Junction-to-case Voltage - Blocking State Repetitive Off-state Current Current - Conducting State Peak On-state Voltage Critical Rate-of-Rise of Commutating Off-state Voltage (Commutating dv/dt) v (Switching)
Symbol Rth(c-f) IDRM VTM (dv/dt)c
Test Conditions - Gate Open Circuited, VD = VDRM, Tj = 125C Tc = 25C, ITM = 45A -
Min. - - - -
Typ. - - - -
Max. 1.2 3 1.6 -
Units C/W mA Volts V/ s
T-88
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR30AM Triac 30 Ampere/400-600 Volts
MAXIMUM ON-STATE CHARACTERISTICS TC= 25oC
TRANSIENT THERMAL IMPEDANCE, Zth(j-c), (C/WATT) INSTANTANEOUS ON-STATE VOLTAGE, VT, (VOLTS)
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS
4.4
102 2.0
103
GATE CHARACTERISTICS (I, II, III)
102
GATE VOLTAGE, VG, (VOLTS)
3.6
1.6 1.2
101
VGM = 10V
PG(avg) = 0.5W PGM = 5W
2.8
VGT = 2.5V
2.0
0.8
100
1.2
0.4 0 10-1 10-1 101
IRGT I, IFGT I, IRGT III VGD = 0.2V
IGM = 2A
0.4 100
101
102
103
100
101
102
102
103
104
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES)
CYCLES AT 60 Hz
GATE CURRENT, IG, (mA)
MAXIMUM SURGE CURRENT FOLLOWING RATED LOAD CONDITIONS
MAXIMUM PEAK SURGE CURRENT, ITSM, (AMPERES)
ALLOWABLE CASE TEMPERATURE VS. RMS ON-STATE CURRENT
ALLOWABLE AMBIENT TEMPERATURE VS. RMS ON-STATE CURRENT
500
160 140
CASE TEMPERATURE, TC, (C)
160 140
AMBIENT TEMPERATURE, Ta, (C) 360 CONDUCTION RESISTIVE, INDUCTIVE LOADS
400
120 100 80 60 40 20
FOR AC CONTROL THIS GRAPH NEARLY APPLIES REGARDLESS OF THE CONDUCTION ANGLE
120 100 80 60 40 20 0
FIN: A PLATE PAINTED BLACK WITH GREASE CURVES APPLY REGARDLESS OF THE CONDUCTION ANGLE RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION 120 x 120 x t 2.3 100 x 100 x t 2.3 160 x 160 x t 2.3
300
200
100
0 100
0 101
CYCLES AT 60 Hz
102
0
10
20
30
40
0
10
20
30
40
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
MAXIMUM ON-STATE POWER DISSIPATION
GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
50
GATE TRIGGER CURRENT, (tC) x 100% GATE TRIGGER CURRENT, (25C) MAXIMUM POWER DISSIPATION, (WATTS)
103
GATE TRIGGER VOLTAGE, (tC) x 100% GATE TRIGGER VOLTAGE, (25C)
103
40
360 CONDUCTION RESISTIVE, INDUCTIVE LOADS
IRGT I, IRGT III IFGT I
30
102
102
20
10 0 0 10 20 30 40 50
RMS ON-STATE CURRENT, IT(RMS), (AMPERES)
101 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
101 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
T-89
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 BCR30AM Triac 30 Ampere/400-600 Volts
HOLDING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
BREAKOVER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
x 100%
BREAKOVER VOLTAGE VS. RATE OF RISE OF OFF-STATE VOLTAGE (TYPICAL)
103
BREAKOVER VOLTAGE, (tC) x 100% BREAKOVER VOLTAGE, (25C) HOLDING CURRENT, (tC) x 100% HOLDING CURRENT, (25C)
160 140 120 100 80 60 40 20 0 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
160 140 120 100 80 60 40 20 0 101 102 103 104
Tj = 125C I QUADRANT III QUADRANT
102
101
-60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
BREAKOVER VOLTAGE, (dv/dt = x V/ s) BREAKOVER VOLTAGE, (dv/dt = 1V/ s)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s)
REPETITIVE PEAK OFF-STATE CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
REPETITIVE PEAK OFF-STATE CURRENT, (tC) x 100% REPETITIVE PEAK OFF-STATE CURRENT, (25C)
COMMUTATION CHARACTERISTICS (TYPICAL)
GATE TRIGGER CURRENT VS. GATE CURRENT PULSE WIDTH (TYPICAL)
105
CRITICAL RATE OF RISE OF OFF-STATE COMMUTATING VOLTAGE, (V/ s)
102
GATE TRIGGER CURRENT, (tw) x 100% GATE TRIGGER CURRENT, (DC)
103
MINIMUM CHARACTERISTICS VALUE
104
101
I QUADRANT Tc = 125oC IT = 4 A = 500 s VD = 200v f = 3 Hz
102
103
Tj = 25C IFGT I IRGT III IRGT I
III QUADRANT
102 -60 -40 -20 0 20 40 60 80 100 120 140
JUNCTION TEMPERATURE, Tj, (C)
100 101
102
RATE OF DECAY OF ON-STATE COMMUTATING CURRENT, (A/ms)
103
101 100
101
GATE CURRENT PULSE WIDTH, tw, ( s)
102
GATE TRIGGER CHARACTERISTICS TEST CIRCUITS
6 A 6V V
6 A V
RG 6V
RG
Part Number BCR30AM-8L
VDRM (Volts) 400 600
Commutating dv/dt, (dv/dt)c (V/ sec) Minimum 20 20
Test Condition Tj = 125C,
Commutating Voltage & Current Waveform (Inductive Load)
SUPPLY VOLTAGE MAIN CURRENT MAIN VOLTAGE (dv/dt)C t (di/dt)C t VD t VD
TEST PROCEDURE I
TEST PROCEDURE II
BCR30AM-12L
6 A 6V V
RG
TEST PROCEDURE III
Rate of Decay On-state Commutating Current (di/dt)c = -016A/msec, Peak Off-state Voltage VD = 400V
T-90


▲Up To Search▲   

 
Price & Availability of BCR30AM-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X