    MS7202-A2

Intersema Sensoric SA
Part No. MS7202-A2
OCR Text ...r, temperature up to 150 C Pads on one side RoHS-compatible & Pb-free1 DESCRIPTION The MS7202-A2 is an absolute silicon micro-machined p...Shore A). Its external size must fit the glass cap. Successful tests were done with some tools of SP...
Description PRESSURE SENSOR DIE (0-2 BAR) FOR HARSH ENVIRONMENT

File Size 196.91K  /  5 Page

View it Online

Download Datasheet





    MS7930-A0.2 MS7930-A0.5 MS7930-D MS7930-S

Intersema Sensoric SA
Part No. MS7930-A0.2 MS7930-A0.5 MS7930-D MS7930-S
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). MS...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-30 BAR)

File Size 215.51K  /  5 Page

View it Online

Download Datasheet

    RF-5800M-MP

Harris Corporation
Part No. RF-5800M-MP
OCR Text ...or added throughput and reduced on-air time. Electronic Protection Measures (EPM) protect communications from hostile interference using frequency hopping techniques. Multiple waveforms are supported, including Harris Quicklook 1A, and opti...
Description FALCON II Advanced tactical radio system

File Size 3,088.11K  /  2 Page

View it Online

Download Datasheet

    PRDS1 PRDS2 PRDS3 PRAS3 PMIR4 PMIR5 PMIS4 PRAS1 PRAS2 PRAS20 PRAS21 PRAS4

ASM GmbH
Part No. PRDS1 PRDS2 PRDS3 PRAS3 PMIR4 PMIR5 PMIS4 PRAS1 PRAS2 PRAS20 PRAS21 PRAS4
OCR Text ...f the PRAS/PRDSseries are based on a contact-free and absolute measurement principle. The position sensing element is a permanent magnet. De...shore applications. External magnetic fields due to power cables, magnetized materials or the earth'...
Description Angle Sensors and Encoders Contents

File Size 2,806.04K  /  52 Page

View it Online

Download Datasheet

    MS7912 MS7912D MS7912A

Intersema Sensoric SA
Part No. MS7912 MS7912D MS7912A
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). The...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-12 BAR)

File Size 253.61K  /  4 Page

View it Online

Download Datasheet

    MS7812-A MS7812-D

Intersema Sensoric SA
Part No. MS7812-A MS7812-D
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). The...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-12 BAR)

File Size 408.18K  /  4 Page

View it Online

Download Datasheet

    MS7904-A0.2 MS7904-A0.5 MS7904-S MS7904-D

Intersema Sensoric SA
Part No. MS7904-A0.2 MS7904-A0.5 MS7904-S MS7904-D
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). ...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-4 BAR)

File Size 215.57K  /  5 Page

View it Online

Download Datasheet

    MS7905-A0.2 MS7905-A0.5 MS7905-D MS7905-S

Intersema Sensoric SA
Part No. MS7905-A0.2 MS7905-A0.5 MS7905-D MS7905-S
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). ...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-5 BAR)

File Size 215.61K  /  5 Page

View it Online

Download Datasheet

    MS7907-A0.2 MS7907-A0.5 MS7907-D

Intersema Sensoric SA
Part No. MS7907-A0.2 MS7907-A0.5 MS7907-D
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). MS...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-7 BAR)

File Size 227.28K  /  5 Page

View it Online

Download Datasheet

    MS7970-A0.2 MS7970-A0.5

Intersema Sensoric SA
Part No. MS7970-A0.2 MS7970-A0.5
OCR Text ...esistances, the voltage applied on the ground pads (GND1 and GND2) has to be lower than the voltage applied on supply voltage pad (Vs+). MS...Shore A). Its external size must fit the sensor and the vacuum cavity must be as large as the membra...
Description PRESSURE SENSOR DIE (0-70 BAR)

File Size 215.26K  /  5 Page

View it Online

Download Datasheet

For on-shore Found Datasheets File :: 166    Search Time::4.172ms    
Page :: | 1 | 2 | 3 | <4> | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

▲Up To Search▲

 




Price and Availability




 
Price & Availability of on-shore

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X
0.17237281799316